Passenger (Inspected) · Passenger Ship class · Built 2010s · USCG Southeast District (CGD-SE) · Other hulls named VIKING SEA
VIKING SEA is a 2016 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2015, most recently in February 2026, along with 15 deficiencies and 1 operational control.
Records from 2015 to 2026. Most recent: inspection, 27 February 2026.
- Built
- 2016
- Last inspected
- 27 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 15 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9725421 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
LAWP7
1358215
Flag
NORWAY
—
Maury page id
psix-1358215
Inspections, by type
…with no type recorded1
Years with a record
11 calendar years (2015–2026)
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it27109 - Displacement, Ton
18858 - Convention (Subpart B), Net Ton
3640 - Dead Weight, Ton
47842 - Convention (Subpart B), Gross Ton
18858 - Convention (Subpart B), Net Ton
3640 - Dead Weight, Ton
47842 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 15
27 February 2026
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8317563
19 December 2025
PSC A · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8277568
30 October 2024
COC-CVE Annual · PSC B · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8026217
16 November 2023
PSC A · Deficiency Check · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7821521
18 December 2022
COC-CVE Annual · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7610017
16 January 2022
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7381051
22 December 2021
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7371543
14 December 2021
PSC B · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7366847
1 November 2021
Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 7343536
28 September 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam · COC-CVE Annual
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6823122
8 March 2019
COC-CVE Quarterly · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6633082
27 September 2018
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6547353
3 October 2017
Ballast Water Examination · ISPS II Exam · COC-CVE Initial
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6280512
26 January 2016
COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 5803333
10 November 2015
COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 5797926
Deficiency record · 15
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 December 2025
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed leak of heavy fuel oil on the #2 pump in STBD purifier room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 December 2025
Resolved
For determining the apporpriate fire integrity standards to be applied to bounderies between adjacent spaces, such spaces are classified according to their fire risk as shown in catergories 1 to 14. PSCO observed combustible materials in multiple locations not allowed by the space classifications per the requirement of the regulation. PSCO observed multiple carboard boxes in the computer room midship on deck 6, eletrical lockers 5.1.02, 4.4.01, deck A carpenter shop and uniform locker on deck A had combustibles stacked higher than the sprinkler head and flammable liquids outside of the paint locker inside the Boson locker.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 December 2025
Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. PSCO observed 02 sliding B-15 class fires that would not close. Doors AD.7.69P and AD.7.68P at hte Wolrd Cafe on deck 7.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 December 2025
Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow.Mechanism was replaced by crew, but still not adequate per the push to open requirement.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 30 October 2024
Resolved
Maintenance, testing and inspections shall be carried out in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO found a hi-pressure water mist suppression flange leaking at an emergency escape trunk, in the engine room. 74SOLAS14 II-2/14.2.2.1 Code 17AC.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 October 2024
Resolved
The construction of doors and door frames in A class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. Fire door A.4.17 and fire door adjacent to it, both are missing the outer frame striker plate, compromising the A boundary inside of the space. 74SOLAS14 II-2/9.4.1.1.2 Code 50AC.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 November 2023
Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions, shall be kept in good order so as to ensure their required performance if a fire occurs. The sliding fire screen roller door 7.4.04 would not close when released by local actuation.
74 SOLAS (20) II-2/14.2.1.1.1
16ac
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 November 2023
Resolved
Fire extinguishing appliances shall be readily available. Excess garbage in the garbage room is blocking fire fighting appliances and plans.
74 SOLAS (20) II-2/10.1.1.2
16ac
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 November 2023
Resolved
Ships of all types shall be subdivided into spaces by thermal and structural divisions having regard to the fire risks of the spaces. The machinery lift stbd side deck 9 space had installed shelving with combustible material.
74 SOLAS (20) II-2/9.2.1
10c
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 November 2023
Resolved
Fire extinguishers shall be situated ready for use at easily visible places, which can be reached quickly and easily at any time in the event of a fire, and in such a way that their serviceability is not impaired by weather, vibration or other external factors. Portable fire extinguishers shall be provided with devices which indicate whether they have been used. The large portable fire extinguisher next to purifier room was not secured.
74 SOLAS (20) II-2/10.3.2.4
10c
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 December 2022
Resolved
The construction of doors and door frames in "A" class divisions shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. Roller shutters located at Dk 7.2.08 and Dk 7.4.04 were misaligned and would not close when activated.74 SOLAS 20 II-2/9.4.1.1.2
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 14 December 2021
Resolved
The public address system shall be clearly audible above the ambient noise in all spaces, and shall be provided with an override function controlled from one location on the navigation bridge. PSCO identified office in Main Laundry on Deck B with no PA system installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 December 2021
Resolved
Automatic sprinkler fire fighting systems shall be of an approved type complying with the requirements of the Fire Safety Code in all control stations. A gauge indicating the pressure in the system shall be provided at each section stop valve. PSCO's tested 15 section valve pressure gauges at multiple section valves in main vertical zones throughout the ship. 08 gauges were found inoperable.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 March 2019
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs, fire detection, structural fire protection. PSCO observed a fixed water sprinkler head that had lost intended fluid at the entrance to the main laundry. SOLAS (Consolodated) II-2/14.1.1 - 10c
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 8 March 2019
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and available for immediate use. PSCO observed battery charging system breaker box on port rescue boat secured with duct tape and not providing a weather tight seal. SOLAS (Consolidated) III/20.2
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.