MAURY USCG vessel records
← All vessels

AFRICAN LILY

AFRICAN LILY is a 2015 public freight. The Coast Guard has recorded 6 inspections since 2018, most recently in October 2023, along with 2 deficiencies and 1 operational control.

Records from 2018 to 2023. Most recent: inspection, 24 October 2023.

Built
2015
Last inspected
24 October 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9666443
1361573
Flag
LIBERIA
Maury page id
psix-1361573

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded3
Years with a record 2 calendar years (2018–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it19213 - Convention (Subpart B), Gross Ton
28341 - Dead Weight, Metric Ton
36449 - Displacement, Metric Ton
9474 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 6

24 October 2023 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7810499
24 October 2023 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7813384
18 October 2023 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7810517
30 November 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6590171
29 November 2018 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6589210
23 November 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6583787

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 November 2018 Resolved
07124- Maintenance of Fire protecetion systems - Fire-fighting systems and appliances shall be kept in good working order and readily available for immediat euse. PSCO observed last annual inspection of fixed co2 fire-fighting system occured on 07Jun2017. SOLAS 74 (a) 2014 II-2/14.2.1 17 a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2018
Resolution: Received tech and class report stating CO2 system received annual servicing.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 November 2018 Resolved
15109 - Maintenance of the ship and equipment - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and any additional requirements which may be established by the company. PSCO observed vessel provided SMS does not maintain procedures for conducting annual inspections of fixed CO3 fire-fighting system as required by SOLAS 74 (a) 2014 II-2/14, MSC/Cir. 1432, and MSC/Cir. 1318. recognized Organization to provide corrective action plan. SOLAS 74 (a) 2014 IX/3 ISM Code 10.1 16 a
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2018
Resolved 29 November 2018
Resolution: Received BV class report clearing deficiency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.