MAURY USCG vessel records
← All vessels

MOLINE

MOLINE is a 1995 towing vessel. The Coast Guard has recorded 4 inspections since 2015, most recently in April 2026, along with 15 deficiencies.

Records from 2015 to 2026. Most recent: inspection, 21 April 2026.

Built
1995
Last inspected
21 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1361670
Flag
UNITED STATES
Maury page id
psix-1361670

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

…with no type recorded1
Years with a record 4 calendar years (2015–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Net Ton
151 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 4

21 April 2026 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8353635
4 February 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8074496
22 January 2024 Initial Certification · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7852884
10 August 2015 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5218938

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 February 2025 Resolved
Fire detection system must be serviced annually. Last service was in 2023.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 21 March 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 February 2025 Resolved
The bilge alarm must have an audible and visual alarm at the operating station. There was no audible alarm at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 21 March 2025
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 February 2025 Resolved
Every flammable cabinet must have a 40-B extinguisher located in the vicinity of it. There was no 40-B extinguisher for the cabinet on the 2nd deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 21 March 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 February 2025 Resolved
The flammable cabinet must be securely attached to the vessel to prevent movement. The cabinet located on the second deck was secured with only 1 bolt and was moving easily.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 21 March 2025
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 30 January 2024 Resolved
Vessel is required to have an installed or portable bilge/dewatering pump onboard. Vessel’s fixed bilge pump was not able to take suction. As a temporary measure place portable pump onboard IAW applicable regulation. Repair, replace, or take out of service fixed bilge system and test to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 23 February 2024
Resolution: Vessels crew placed portable bilge/dewatering pump onboard and documentation of function test received.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 January 2024 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (5) High bilge levels, and must be visible and audible at each operating station. The vessel’s crew was unable to perform or show that the alarm was functioning properly. Provide proof of proper operation and/or replace installed high bilge level alarms.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 23 February 2024
Resolution: Crew provided proof of proper operation of installed high bilge level alarms.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 30 January 2024 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (6) Low hydraulic steering fluid levels and Alarms must be visible and audible at each operating station. The audible low hydraulic steering fluid level alarm is installed but not operational at the operating station. Repair or replace the low hydraulic steering fluid level audible alarm at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 19 July 2024
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 30 January 2024 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists to include a low lubricating oil pressure alarm. The vessel’s crew was unable to perform or show that the alarm was installed and/or functioned properly. Install and/or test low level lube alarm on main diesel engines / generator.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 19 July 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 January 2024 Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section; or a portable pump, and hoses and nozzles, in accordance with paragraphs (e) and (f) of this section. (d) The hose must be a lined commercial fire hose 15 meters (50 feet) in length, at least 40 millimeters (1.5 inches) in diameter. The fixed fire main system fire stations are fitted with 1” diameter hose. Install 1.5” diameter hose at each fire station if minimum 50 PSI and 80 GPM can be achieved or as a temporary measure place self-priming portable pump onboard IAW applicable regulation. Repair, replace, or take out of service fixed fire main system and test to the satisfaction of attending Marine Inspector.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2024
Resolved 23 February 2024
Resolution: Self-priming, portable fire pump placed on board, proof of function test received.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 30 January 2024 Resolved
Fire-detection system requirements, (2) The system is installed, tested, and maintained in accordance with the manufacturer's design manual. The installed fire detection system was tested and found operational, but the fire alarm panel trouble light remained illumined. Repair or replace required components needed to clear system fault.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2024
Resolved 23 February 2024
Resolution: Fire control pannel repaired, system fault cleared.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 January 2024 Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Vessel’s engine room watertight door had a faulty gasket. Renew / replace faulty gasket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2024
Resolved 23 February 2024
Resolution: Vessel’s engine room watertight door gasket replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 January 2024 Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. The port main engine exhaust bellows near turbo was cracked and had temporary repairs. Permanently repair or replace Port MDE exhaust bellows and re-install exhaust lagging.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2024
Resolved 23 February 2024
Resolution: Turbo bellows and insulation replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The vessel has plastic ties serving as cable supports. Replace plastic ties with a more suitable fire-resistant material.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2024
Resolved 23 February 2024
Resolution: Plastic ties replaced with stainless steel ties
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 30 January 2024 Resolved
The following systems must be equipped with gauges at the machinery location. The generator did not have an RPM gauge. Install an RPM gauge for the generator at the machinery location.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2024
Resolved 19 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 January 2024 Resolved
Each lifebuoy on a towing vessel must, be marked in block capital letters with the name of the vessel. The on-board life rings were not yet marked as required, Label all onboard life rings with the name of the vessel in block capital letters.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2024
Resolved 23 February 2024
Resolution: New lifebouy’s have arrived and been labled and placed into service.

Ownership record