MAURY USCG vessel records
← All vessels

SARAH D

Built
1975
Last inspected
26 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 26 June 2026
…with no type recorded25
Operational controls None recorded without a removal date
Years with a record 27 calendar years (1991–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7400510
WDI9093
136471
Flag
UNITED STATES
Maury page id
psix-136471

Documentation record

Registered dimensions (L × B × D)89.8 ft × 28.9 ft × 12.1 ft
Registered tonnagegross 162 / net 110
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNKNOWN · PALATKA, FL, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portTROY, NY
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 20 November 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it162 - Regulatory (Subpart C or D), Gross Ton
110 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 50 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 13 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 13

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest. Towing vessels are barely present in the record before 1992, so tow-unit membership for activities older than that is recorded only partially.

WEEKS 533 Industrial Vessel · MISLE 48313 · 15 December 2022 · activity 7615662ALLIE B Towing Vessel · MISLE 149087 · 15 December 2022 · activity 7615662HG 105 Freight Barge · MISLE 608765 · 18 February 2021 · activity 7144392HG 205 Freight Barge · MISLE 1330777 · 6 February 2021 · activity 7138835HG 204 Freight Barge · MISLE 1330779 · 6 February 2021 · activity 7138835HG 210 Freight Barge · MISLE 1330783 · 6 February 2021 · activity 7138835AVA FAITH Towing Vessel · MISLE 92904 · 26 January 2015 · activity 5059382AVA FAITH Towing Vessel · MISLE 92904 · 1 December 2014 · activity 5039597AVA FAITH Towing Vessel · MISLE 92904 · 22 October 2010 · activity 3879903CABO PEYO Towing Vessel · MISLE 120022 · 18 September 2002 · activity 1680051CAPTAIN ARTHUR FOURNIER Towing Vessel · MISLE 118855 · 1 June 1998 · activity 20249ANN MORAN Towing Vessel · MISLE 153352 · 8 October 1995 · activity 180491TMT FORTALEZA Freight Barge · MISLE 46572 · 31 December 1991 · activity 45864EDWARD BRUSCO Towing Vessel · MISLE 86732 · 31 December 1991 · activity 45864EXPLORER Towing Vessel · MISLE 133702 · 31 December 1991 · activity 45864

Inspection history · 50

26 June 2026 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8416332
12 May 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8133030
1 April 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8097701
5 April 2024 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7890678
10 May 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7700499
15 December 2022 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7615662
23 June 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7485014
11 March 2022 Administrative Inspection · Examination of Repairs · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7410387
9 June 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7220698
24 March 2021 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7162461
24 March 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7162496
18 February 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7144392
6 February 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7138835
23 October 2020 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7082985
17 June 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7000841
10 June 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6973284
13 October 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6836296
15 June 2019 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6714597
22 October 2018 COI Inspection · Initial Certification · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6571731
25 May 2017 Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6155215
26 January 2015 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5059382
1 December 2014 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5039597
25 November 2014 Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5019464
31 July 2014 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4940990
24 September 2012 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4454792
31 May 2012 MTSA Verification · Industry Initiated Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4343057
21 November 2011 Type not recorded
No type recorded · USCGC CAPSTAN (WYTL 65601) · USCG East District (CGD-E) · Activity 4201781
24 May 2011 Type not recorded
No type recorded · USCGC CAPSTAN (WYTL 65601) · USCG East District (CGD-E) · Activity 4031433
22 October 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3879903
20 May 2010 Industry Initiated Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3747140
23 March 2010 Type not recorded
No type recorded · USCGC CLEAT (WYTL 65615) · USCG East District (CGD-E) · Activity 3702435
5 June 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3501125
23 April 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3192358
18 December 2007 Type not recorded
No type recorded · USCGC CLEAT (WYTL 65615) · USCG East District (CGD-E) · Activity 3120837
23 February 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2667324
18 September 2002 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1680051
1 August 2002 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1679271
9 July 2002 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1643300
15 April 2002 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1607462
2 November 2000 Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1055116
7 July 2000 Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1051557
20 May 1999 Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 800033
11 June 1998 Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1129823
1 June 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 20249
13 April 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 42936
25 June 1996 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1380559
8 October 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 180491
31 December 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 45864
24 August 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 59227
15 June 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 93459

Deficiency record · 6

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 May 2025 Resolved
143.450 when pulling, pushing or hauling alongside one or more barges, must have a system to detect when its master or mate (pilot) becomes incapacitated...Vessel did not have pilothouse alerter system installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2025
Resolved 2 June 2025
Resolution: Received objective evidence of installed pilothouse alerter system.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 12 May 2025 Resolved
143.230 Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention...143.245 Twice every 5 years, with no more than 3 years elapsing since last test...Vessel crew could not perform or provide record of main engine or auxiliary generator high cooling water temperature alarms
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2025
Resolved 2 June 2025
Resolution: Received objective evidence of testing for main engine and auxiliary generator high cooling water temperature alarms.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 April 2025 Resolved
Crop and renew upper horizontals in steering lazarette aft of Port and STBD manhole entrances. 46 CFR 137.330(b)
Action required: 705 - Other - as specified
Resolved 8 April 2025
Resolution: Inspector confirmed repairs and took pictures.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 June 2021 Resolved
AT LEAST TWO LIFEBUOYS ON A VESSEL OVER 26-FT SHALL BE EQUIPPED WITH A FLOATING ELECTRIC WATERLIGHT. ALL FLOATING WATER LIGHTS HAD MISSING AND DETERIORATED GASKETS.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 8 September 2021
Resolution: Provided evidence of compliance
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 June 2021 Resolved
EVERY TOWING VESSEL OF GREATER THAN 26-FEET IN LENGTH MUST HAVE A RADIOTELEPHONE IN COMPLAINCE WITH THE BRIDGE TO BRIDGE ACT. THE VESSEL DID NOT HAVE A VALID BRIDGE TO BRIDGE OR RADIOTELEPHONE CERTIFICATE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 8 September 2021
Resolution: provided Evidence of compliance
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 March 2021 Resolved
The vessel found a crack in the hull approximately 1/2” x 3” in the engine room IWO 1ft from keel gen set area. Wedges and oakum material were used to slow the water ingress to a minimum and are currently at your home port in Bayonne. Must submit a tow assist plan for approval to VTS prior to movement and submit a repair plan for approval to Coast Guard Marine Inspector (CGMI) prior to conducting operations and/or movement from shipyard. Repair plan must be approved by CGMI prior to conducting repair.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 March 2021
Resolution: Satisfactory 18x18 patch has been welded in place and tested.

Recorded names · 1

HELEN D. COPPEDGE (2002–2015). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.