MAURY USCG vessel records
← All vessels

ARCADIA

ARCADIA is a 2015 freight ship. The Coast Guard has recorded 21 inspections since 2016, most recently in March 2026, along with 4 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: operational control imposed, 13 March 2026.

Built
2015
Last inspected
13 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9695640
9HA4016
1365625
Flag
MALTA
Maury page id
psix-1365625

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded4
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it13035 - Convention (Subpart B), Net Ton
49212 - Displacement, Metric Ton
39202 - Dead Weight, Metric Ton
25303 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 21

13 March 2026 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8325706
12 March 2026 COE-Administrative
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8325423
7 March 2025 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8087961
30 November 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8041367
27 June 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7488654
7 June 2022 PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7471215
11 June 2020 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6972315
18 May 2020 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6952747
14 April 2020 Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6938860
1 April 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6934027
25 March 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6931390
10 October 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6832394
29 June 2018 COE-Administrative
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6457788
19 March 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6371141
25 February 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6346073
3 February 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6349125
3 February 2018 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6349127
15 February 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6083941
12 August 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5970535
30 January 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5806552
28 January 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5805012

Deficiency record · 4

Engineering › Steam Boiler (auxiliary/waste heat) › Blowdown System
Issued 15 February 2017 Resolved
DURING EXAM, PSCO NOTED TEMPORARY CONCRETE REPAIR ON AUX BOILER BLOW DOWN VALVE IN ENGINE ROOM. VALVE IS STILL FUNCTIONAL, BUT CRACKED AND LEAKING.
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 19 February 2017
Resolution: Rcvd class report from RINA attesting to repairs/replacement of valve. Tested and found in good order.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 February 2017 Resolved
05 OF THE VESSEL'S SELF-IGNITING LIFEBUOY LIGHTS DID NOT FUNCTION DURING THE EXAM.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2017
Resolved 16 February 2017
Resolution: Rcvd class report attesting to replacement of lights.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 15 February 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 17 February 2017
Resolution: Rcvd copy of Endorsement issued by Flag (Malta)
Engineering › Steering Gear System › Ram
Issued 28 January 2016 Resolved
0936 - Every ship shall be provided with a main steering gear and an auxiliary steering gear to the satisfaction of the Administration. During steering gear test it was observed that all rudder angle indicators and hydraulic ram exhibited hunting of approximately three degrees variance while attempting to reach angles ordered between 10 degrees port and 10 degrees starboard. SOLAS (14) II-1/29.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 January 2016
Resolution: MI attended and cleared vessel.

Ownership record