Records from 2000 to 2020. Most recent: inspection, 2 December 2020.
Documentation record
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Net Ton
68 - Convention (Subpart B), Net Ton
90 - Regulatory (Subpart C or D), Gross Ton
227 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
2 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7104846
12 November 2015
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5762483
2 May 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4850796
24 February 2012
Annual Inspection · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4250466
6 December 2011
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 4204435
9 February 2010
Drydock Exam · Administrative Inspection · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3677379
17 February 2009
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3419990
21 April 2008
Hull Examination · Periodic Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3189141
26 March 2007
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2895616
6 April 2006
Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2653105
11 February 2005
MTSA Verification · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2290782
6 February 2005
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2287818
23 March 2004
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2029723
6 June 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1810979
12 March 2002
Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1493231
17 April 2001
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1468207
9 March 2000
Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437645
9 March 2000
Inclining Experiment · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445600
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 24 February 2012
Resolved
Replace dryer vent with vent louver arrangement
Due 14 March 2012
Resolved 2 March 2012
Resolution: Recieved picture of the vent louver arrangement.
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 24 February 2012
Resolved
replace water heater relief valve to 100 psi relief valve
Due 12 March 2012
Resolved 2 March 2012
Resolution: Received picture of the correct relief valve for water heater.
Deck/Cargo › Ballast › Vents
Issued 24 February 2012
Resolved
place insect screens on all water tank vents
Due 12 March 2012
Resolved 2 March 2012
Resolution: received pictures from vessel operator of insect screens installed on water tank vents.
Communications › Radio Communications › EPIRB
Issued 17 February 2009
Resolved
Reposition epirb so that it is in a float free configuration.
Due 22 February 2009
Resolved 18 February 2009
Resolution: Epirb was moved.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 6 June 2003
Resolved
Provide compass deviation card.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2003
Resolved 7 June 2003
Lifesaving › Buoyant Apparatus
Issued 6 June 2003
Resolved
Renew 2 cracked lifefloats. LEGACY COMPONENT DESC: life floats
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2003
Resolved 6 June 2003
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 June 2003
Resolved
Provide aft deck railing for passenger safety.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2003
Resolved 7 June 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 6 June 2003
Resolved
Install 2 inch extensions at end of both branch lines.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2003
Resolved 7 June 2003