CAPT BRENNAN

CAPT BRENNAN is a 2015 towing vessel. The Coast Guard has recorded 17 inspections since 2015, most recently in July 2026, along with 11 deficiencies.

Records from 2015 to 2026. Most recent: inspection, 17 July 2026.

Built
2015
Last inspected
17 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 17 July 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2015–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI4091
1370341
Flag
UNITED STATES
Maury page id
psix-1370341

Documentation record

Registered dimensions (L × B × D)67.0 ft × 27.0 ft × 8.0 ft
Registered tonnagegross 96 / net 77
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULFBOUND LLC · Chauvin, LA, UNITED STATES · built 2015
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portVENICE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 December 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Simplified, Gross Ton
77 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

17 July 2026 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8436804
3 June 2025 Administrative Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8151372
24 April 2025 COI Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8118117
14 November 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8040228
30 October 2024 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8027269
28 November 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7830847
18 September 2023 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7793551
14 July 2023 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7742678
26 January 2023 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7627639
11 August 2022 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7531092
12 October 2021 Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7311400
17 August 2020 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7037871
13 August 2020 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7031686
28 July 2020 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7017993
14 July 2020 Initial Certification
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6962289
12 January 2016 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5793639
5 October 2015 Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5736981

Deficiency record · 11

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2024 Resolved
Each vessel with a capacity of 250 or more barrels (10,500 gal) of oil shall provide transfer procedures for transferring (a) To or from the vessel; and (b) From tank to tank within the vessel. Vessel carries more that 250 barrels of fuel and does not have transfer procedures.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 November 2024
Resolved 4 November 2024
Resolution: Provided transfer procedures for the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2023 Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. Vessel's port and starboard air compressor vessels have a MAWP of 150 PSI with both relief valves at 200 PSI. Vessel to install relief valves to not exceed the MAWP by to the satisfaction of Coast Guard Marine Inspector. 46 CFR 143.300 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2023
Resolved 23 October 2023
Resolution: Relief valves replaced.
01 - Certificates & Documentation › 012 - Crew Certificates › Cert for personnel on survival craft & rescue boat
Issued 10 October 2023 Resolved
Crewmembers must meet the requirements in §§ 15.405 and 15.1105 of this chapter, as appropriate. Crewmembers were unfamiliar with life raft operations and did not have certified Lifeboatmen. A Crewmember is to be certified Lifeboatmen and provide certification to the satisfaction of Coast Guard Marine Inspector. 46 CFR 140.405 (a)
Action required: 705 - Other - as specified
Due 27 November 2023
Resolved 30 October 2024
Resolution: Reviewed crew training of life raft deployment and operation.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 July 2020 Resolved
Users must always maintain their Automatic Identification System in an effective operating condition and ensure the accuracy of all broadcasted dynamic, static and voyage information in accordance with 33 CFR 164.46(d). This vessel is currently transmitting an incorrect value for their IMO number and a zero value for the vessel’s draft. Correct all incorrect values being transmitted through the AIS to the satisfaction of an attending Coast Guard Marine Inspector prior to August 13, 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Pulled up the broadcast data for the vessel in VIVS and all broadcast information is now correct.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 14 July 2020 Resolved
A Marine Employer must provide an EAP education program for for the employer's crew members and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crew members and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Provide EAP supervisory and employee training and provide training records to the satisfaction of an attending Coast Guard Marine Inspector prior to August 13, 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 17 August 2020
Resolution: Owner provided Objective Evidence in the form of records that demonstrated compliance with the EAP training requirements.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 14 July 2020 Resolved
Marine Employers must ensure that they and their crew members have met the requirements of a Chemical Testing Program as required in 46 CFR 16.203(a). Provide documentary proof of pre-employment tests and random drug tests for the last 12 months through Medical Review Officer letter for each drug test. The paperwork must be submitted to the satisfaction of an attending Coast Guard Marine Inspector prior to August 13, 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 20 August 2020
Resolution: Owner provided Objective Evidence in the form of a Certificate of Compliance and crew roster of enrolled employees in a chemical testing program and pre-employment test results for each crew member on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 July 2020 Resolved
Personnel dispatched from the vessel or that are working in an area on the exterior of the vessel without rails and guards must wear a work vest approved by the Commandant under 46 CFR subpart 160.053. The crew is currently utilizing Type III PFD's under CG Approval 160.064. Owner must either provide the appropriate work vests in accordance with 46 CFR 140.430(a) or request a Special Consideration from the local OCMI in accordance with CVC Work Instruction (CVC-WI-010(1) prior to August 13, 2020
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 28 July 2020
Resolution: Special Consideration Letter was approved by the OCMI for use of type III life jackets to be used in lieu of work vests.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 July 2020 Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must have a indicating pressure gauge visible to the crew in accordance with 46 CFR 143.300(a). There was an indicating pressure gauge affixed to each tank but the locations was such a way that it was not visible by the crew. Move of provide another means for the crew to clearly see the pressure of both air receivers to the satisfaction of an attending Coast Guard Marine Inspector prior to August 13, 2020
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Master/Owner provided photographic evidence that pressure gauges have been installed and are clearly visible to the crew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 July 2020 Resolved
Each towing vessel fitted with an installed bilge pump and piping system must have a check/foot valve installed on the suction side that prevents unintended back flooding through the bilge piping in accordance with 46 CFR 143.275. During a test of the vessel bilge dewatering system, there was no foot/check valve installed. Properly install a foot/check valve on the suction side of the each bilge piping to the satisfaction of an attending Coast Guard Marine Inspector no later than August 13, 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Master/owner provided photographic evidence that a check valve was installed on each bilge suction pipe in various location in the below deck spaces.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 July 2020 Resolved
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan to ensure proper operation of the system. Vessel unable to provide proof of documented maintenance and documentation they are following the maintenance for fuel system. Provide documented maintenance plan for the fuel systems in way of the main engines and generators to the satisfaction of an attending Coast Guard Marine Inspector prior to August 13, 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 17 August 2020
Resolution: Owner provided Objective Evidence in the form of Maintenance Plans from the main engine and generator manufaturerers and records of the latest maintenance as specified by the manufacturer.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 July 2020 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and may be automatic, battery-operated with a duration of no less than 2 hours or Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. The stairwell on the upper deck in way of the crew stateroom was not sufficiently illuminated in the event of power loss. Install an acceptable form of emergency lighting in this location to the satisfaction of an attending Coast Guard Marine Inspector prior to August 13, 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Master/owner provided photographic evidence that emergency lighting was installed on the 02 deck illuminating the escape route to the main deck in the event of an emergency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.