MAURY USCG vessel records Sign in
← All vessels

DEWITT ELEVATOR

DEWITT ELEVATOR is a 1975 offshore supply vessel. The Coast Guard has recorded 23 inspections since 1991, most recently in May 2018, along with 45 deficiencies and 1 operational control.

Records from 1991 to 2018. Most recent: inspection, 17 May 2018.

Built
1975
Last inspected
17 May 2018
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYN6211
137051
Flag
UNITED STATES
—
Maury page id
psix-137051

Inspections, by type

Years with a record 19 calendar years (1991–2018)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)64.0 ft × 24.0 ft × 4.4 ft
Registered tonnagegross 82 / net 74
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS INC · CAERNARVON, LA, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Regulatory (Subpart C or D), Gross Ton
74 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

17 May 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6417027
8 March 2017 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6100894
17 January 2017 Administrative Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6072056
4 December 2015 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5775669
14 October 2014 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5005492
7 October 2014 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5000965
13 March 2014 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4814810
29 November 2010 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3932969
4 December 2008 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3374174
6 September 2007 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3051762
16 August 2006 Hull Examination · Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2749965
20 June 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2396253
28 April 2004 Hull Examination · Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2052919
26 June 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1827231
25 April 2002 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1615379
16 May 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439213
26 May 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403141
30 April 1999 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452508
10 December 1998 Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 809035
4 January 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1161371
4 May 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 946472
4 February 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1256331
22 February 1991 Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998373

Deficiency record · 45

Engineering › Lubricating Oil Service System › Gauge
Issued 8 March 2017 Resolved
Port Main Diesel Engine gauge was inoperable on Bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 10 March 2017
Resolution: Gauge was replaced.
Lifesaving › Lifefloat › Painter
Issued 4 December 2015 Resolved
Secure life float painter and waterlight to life float in accordance with 46 CFR 180.175.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2015
Resolved 4 December 2015
Resolution: Corrected during inspection.
Communications › Radio Communications › EPIRB
Issued 4 December 2015 Resolved
Replace expired EPIRB HRU per 46 CFR 180.64.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2015
Resolved 4 December 2015
Resolution: Replaced EPIRB HRU during inspection.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 December 2015 Resolved
Properly install electrical panel in port-side engine room per 46 CFR 183.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 December 2015
Resolved 7 December 2015
Resolution: Electrical panel properly installed.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 4 December 2015 Resolved
Join the metallic sections of the fuel oil fill pipes separated by non-metallic hose with bonding straps (electrical conductor) for protection against static spark when filling per 46 CFR 182.20-30.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 December 2015
Resolved 7 December 2015
Resolution: Bonding straps installed per 46 CFR 182.20-30.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 December 2015 Resolved
Permanently wire starboard engine room exhaust fan per 46 CFR 183.
Action required: 705 - Other - as specified
Due 15 December 2015
Resolved 7 December 2015
Resolution: Permanently wired starboard engine room exhaust fan.
Documentation › Markings/Placards › Warning Signs
Issued 4 December 2015 Resolved
Emergency exit signs at port and starboard engine room egress obscured by paint. Provide legible emergency exit signs at port and starboard engine room egress per 46 CFR 185.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 December 2015
Resolved 7 December 2015
Resolution: Replaced egress markings.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 4 December 2015 Resolved
Properly secure Marine Sanitation Device pump and float switch.
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 4 December 2015
Resolution: Secured pump and float switch.
Communications › Alarms/Indicators › High Water Alarm
Issued 7 October 2014 Resolved
Engine room bilge alarm does not sound or illuminate light on operating station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2014
Resolution: replaced bilge high water sensor, tested sat.
Communications › Alarms/Indicators › General Alarm
Issued 7 October 2014 Resolved
Vessels tilt alarm in inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2014
Resolution: Tested tilt alarm, all sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 7 October 2014 Resolved
Portable dry chem on deck severly corroded around base.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2014
Resolution: new portable dry chem provided.
Construction/Loadline › Hull › Hull Plating
Issued 7 October 2014 Resolved
Hull plating wasted on the port side engine room near the vent. Crop and renew to good metal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2014
Resolution: cropped and renewed metal. all sat.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 13 March 2014 Resolved
Make engine room escape hatch operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 27 March 2014
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 13 March 2014 Resolved
Tighten starboard main engine mount.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 27 March 2014
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 13 March 2014 Resolved
Cover openings in main distribution panel (deck mounted generator).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 27 March 2014
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 March 2014 Resolved
Cover 110 V receptacles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 27 March 2014
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 March 2014 Resolved
Replace wasted handrails.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 27 March 2014
Engineering › Lubricating Oil Service System › Gauge
Issued 13 March 2014 Resolved
Ensure proper operation of the P/S lube oil guages.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 27 March 2014
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 13 March 2014 Resolved
Re-install (main) cabin fire extinguisher mount.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 27 March 2014
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 March 2014 Resolved
Properly maintenance forward leg. Gear box cover bent open, and all gear box / leg mount areas severely corroded, remove wastage for preservation and reinstall cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 27 March 2014
Communications › Radio Communications › Emergency Source of Power
Issued 29 November 2010 Resolved
Demonstrate proper operation of PA system on back up power.
Action required: 705 - Other - as specified
Resolved 3 December 2010
Lifesaving › Hand Flares › Expired
Issued 29 November 2010 Resolved
Replace 6 hand held flares.
Action required: 705 - Other - as specified
Resolved 3 December 2010
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 29 November 2010 Resolved
Demonstrate proper operation of engine RPM gauge at operating station.
Action required: 705 - Other - as specified
Resolved 3 December 2010
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 29 November 2010 Resolved
Renew/replace oil pressure gauge at operating station.
Action required: 705 - Other - as specified
Resolved 3 December 2010
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 29 November 2010 Resolved
Replace broken line on MSD
Action required: 705 - Other - as specified
Resolved 3 December 2010
Deck/Cargo › Holds/Tanks › Hatch
Issued 29 November 2010 Resolved
Replace gasket on hatch cover on hatch to engine room directly aft of house.
Action required: 705 - Other - as specified
Resolved 3 December 2010
Electrical › Electrical Distribution System (service) › Cable
Issued 4 December 2008 Resolved
Renew battery cable connector terminal at stbd MDE starting battery.
Due 11 December 2008
Resolved 4 December 2008
Resolution: Replaced same day
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 December 2008 Resolved
Repair broken deck rain adjacent to top of ladder leading to wheelhouse deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2008
Resolution: Repaired same day
Construction/Loadline › Structures › Door
Issued 6 September 2007 Resolved
REPAIR WEATHERTIGHT DOOR ON BATHROOM ENTRANCE.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2007
Resolved 6 September 2007
Resolution: COMPLETED
Construction/Loadline › Structures › Door
Issued 6 September 2007 Resolved
INSTALL LATCH ON MACH. SPACE DOOR.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2007
Resolved 6 September 2007
Resolution: COMPLETED
Construction/Loadline › Structures › Door
Issued 6 September 2007 Resolved
REPAIR PILOT HOUSE DOOR AND MAKE WATERTIGHT.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2007
Resolved 6 October 2007
Resolution: COMPLETED
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 September 2007 Resolved
RENEW GREEN RUNNING LIGHT.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2007
Resolved 6 September 2007
Resolution: COMPLETED
Engineering › Diesel Engine (propulsion-electric) › Gear/Clutch Starter (hydraulic)
Issued 6 September 2007 Resolved
INSTALL GUARD PN PTO ON MAIN ENGINE.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2007
Resolved 6 September 2007
Resolution: COMPLETED
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 6 September 2007 Resolved
INSTALL APPROVED F/O HOSES MEETING J1942 ON BOTH MAIN ENGINES.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2007
Resolved 6 October 2007
Resolution: COMPLETED
Documentation › Markings/Placards › Oil Discharge Placard
Issued 6 September 2007 Resolved
POST OIL POLLUTION PLACARD AT BILGE PUMP SWITCH.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2007
Resolved 6 September 2007
Resolution: COMPLETED
Construction/Loadline › Structures › Trunk
Issued 6 September 2007 Resolved
WELD STARBOARD WATER VENT AT OVERHEAD IN ENGINE ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2007
Resolved 6 September 2007
Resolution: COMPLETED
Documentation › Markings/Placards › Warning Signs
Issued 6 September 2007 Resolved
POST EMERGENCY ESCAPE PLACARD AT ENGINE ROOM AFT ESCAPE HATCH.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2007
Resolved 6 September 2007
Resolution: COMPLETED
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 6 September 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2007
Resolved 6 September 2007
Resolution: COMPLETED
Lifesaving
Issued 30 April 1999 Resolved
DEMONSTRATE COMPLIANCE WITH THE 8TH U.S. COAST GUARD DISTRICT'S POLICY "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS" DATED 12NOV98 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 30 April 1999
Resolved 30 April 1999
Accommodation/Occupational Safety
Issued 22 February 1991 Resolved
PROVIDE AN APPROVED BUNK LIGHT FIXTURE FOR EACH OF THE CREWMEMBERS BUNK AREA.
Condition: Unknown
Due 22 February 1991
Resolved 22 February 1991
Construction/Loadline
Issued 22 February 1991 Resolved
PROVIDE THE FOOLOWING PLANS AS REQUIRED BY NVIC 8-81 CH 1 TO THE OCMI NEW_x001C_ ORLEANS TO FORWARD TO COMMANDANT(G-MSC) FOR APPROVAL: GENERAL ARRANGEMENTS,INBD/OUTBD PROFILES, LEG/LEG FOUNDATION STRUCTURES, JACKING TOWER STRUCT- URES, HYD. SYSTEMS AND FIRE/SAFETY ARRANGEMENTS PLAN.
Condition: Unknown
Due 22 February 1991
Resolved 22 February 1991
Documentation
Issued 22 February 1991 Resolved
PROVIDE A COMPLETE OPERATING MANUAL IN ACCORDANCE WITH 46CFR109.121 & NVIC 8-81 CH1, FOR REVIEW, TO THE [name withheld] TO FORWARD TO COMMANDANT(G- MSC). OPERATING MANUAL WILL ALSO ADDRESS USE OF HIGH TENSILE STEEL & REPAIRPROCEDURES. TO ADDRESS THE MARPOL V WASTE MANAGEMENT PLAN REQUIEMENTS ALSO.
Condition: Unknown
Due 22 February 1991
Resolved 22 February 1991
Documentation
Issued 22 February 1991 Resolved
SUBMIT STABILITY CALCULATIONS FOR REVIEW AND APPROVAL TO COMMANDANT(G-MSC)_x001C_IAW 46CFR SUBCHAPTER S SUBPART C. STABILITY LETTER TO BE PROPERLY POSTED ONCE APPROVED AND RECIEVED.
Condition: Unknown
Due 22 February 1991
Resolved 22 February 1991
Documentation
Issued 22 February 1991 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 February 1991
Resolved 22 February 1991
Accommodation/Occupational Safety
Issued 22 February 1991 Resolved
PROVIDE MSD OVERBOARD BYPASS PIPING WITH A CHECK VALVE AS REQUIRED BY 46CFR56.50-95._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1991
Resolved 22 February 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.