MAURY USCG vessel records Sign in
← All vessels

NORDORINOCO

NORDORINOCO is a 2015 freight ship. The Coast Guard has recorded 8 inspections since 2017, most recently in May 2026, along with 1 deficiency and 1 operational control.

Records from 2017 to 2026. Most recent: inspection, 19 May 2026.

Built
2015
Last inspected
19 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9741712 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1371219
Flag
PORTUGAL
—
Maury page id
psix-1371219

Inspections, by type

…with no type recorded3
Years with a record 5 calendar years (2017–2026)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it23974 - Convention (Subpart B), Gross Ton
12927 - Convention (Subpart B), Net Ton
38040 - Dead Weight, Metric Ton
47422 - Displacement, Metric Ton
23974 - Simplified, Gross Ton
12927 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 8

19 May 2026 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8376090
9 October 2024 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8010371
1 February 2023 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7630090
29 January 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6345419
25 January 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6343841
10 October 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6284388
8 October 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6283649
5 October 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6282313

Deficiency record · 1

Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 October 2017 Resolved
Fire doors in... galley bounderies... shall be self closing. 02 Fire doors leading to the galley would not fully close. 74 SOLAS (2014 Cons) 11-2/9.4.1.1.5.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 10 October 2017
Resolution: Fire doors were repaired and inspected by the Marine Inspectors.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.