MAURY USCG vessel records
← All vessels

ASTRO NEKKAR

ASTRO NEKKAR is a 2016 freight ship. The Coast Guard has recorded 3 inspections since 2017, most recently in September 2025, along with 5 deficiencies.

Records from 2017 to 2025. Most recent: inspection, 3 September 2025.

Built
2016
Last inspected
3 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9720304
1371421
Flag
MARSHALL ISLANDS
Maury page id
psix-1371421

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 2 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it35884 - Convention (Subpart B), Gross Ton
63027 - Dead Weight, Metric Ton
74943 - Displacement, Metric Ton
21200 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

3 September 2025 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8214178
26 September 2017 NPV Safety Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6275145
5 September 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6254471

Deficiency record · 5

Engineering › Lubricating Oil Service System › Pump
Issued 26 September 2017 Resolved
1410- Propulsion main engine- After any survey the ship and equipment will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel had reduced propullsion diverting to a nearby berth. 74 SOLAS (14 Cons.) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 September 2017
Lifesaving › Lifeboat Equipment › Food Ration
Issued 5 September 2017 Resolved
0611- Lifeboat inventory- Food rations in life boat does not total 10,000 kj for each persons the lifeboat is permited to accomodate. PSCO Observed 1 food ration in lifeboat not airtight and deteriorated. SOLAS 2014 III/34 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 September 2017
Resolved 7 September 2017
Resolution: PSC received class report from LR clearing all requirements.
Fire Fighting › Portable Foam Applicators › General
Issued 5 September 2017 Resolved
0720-Fire fighting equipment- Portable foam applicator unit shall consist of a foam nozzle with a portable tank containing 20 L of foam concentrate and atleast one spare tank. PSCO observed spare foam tank half empty and stored in a air compressor oil bottle. SOLAS 2014 II-2/10.5.2.2.1 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2017
Resolved 7 September 2017
Resolution: PSC received class report from LR clearing all requirements.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 5 September 2017 Resolved
0799- Other(Fire fighting equipment)- Fixed fire fighting equipment shall be periodically tested to the satisfaction of the administration. PSCO observed vessel did not have proper equipment to test flame detection. SOLAS 2014 II-2/7.3.2 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 September 2017
Resolved 7 September 2017
Resolution: PSC received class report from LR clearing all requirements.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 5 September 2017 Resolved
9900- Other(Not clearly hazardous)- Transfer Procedures required by 155.720 must contain either in order or by use of cross reference the following information. PSCO observed the vessel has no transfer procedures. 33 CFR 155.750 c
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 5 September 2017
Resolved 6 September 2017
Resolution: PSC reviewed Oil Transfer Procedures and accepted.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.