MAURY USCG vessel records
← All vessels

TRIDENT STAR

TRIDENT STAR is a 2015 freight ship. The Coast Guard has recorded 11 inspections since 2018, most recently in April 2026, along with 3 deficiencies and 2 operational controls.

Records from 2018 to 2026. Most recent: inspection, 12 April 2026.

Built
2015
Last inspected
12 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9707637
1371436
Flag
HONG KONG
Maury page id
psix-1371436

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 6 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it32370 - Convention (Subpart B), Gross Ton
57836 - Dead Weight, Ton
67810 - Displacement, Ton
19449 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 11

12 April 2026 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8346470
5 March 2025 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8085298
14 August 2022 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7532979
31 May 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7464085
27 May 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7460717
26 March 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7163351
10 February 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7138627
10 January 2021 Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7122249
12 November 2020 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7093855
16 March 2020 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6924545
9 August 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6506367

Deficiency record · 3

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 March 2025 Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration in accordance with the provisions of regulation XI - 1/1, or with applicable national standards of the Administration which provide an equivalent level of safety. PSCO observed two areas wrapped in plastic bags near engine. When plastic bags were removed, PSCO observed electrical tape wrapped around piping. Chief engineer explained this was due to recent welding repair that was not reported to Class. The second bag was obscuring a valve that was being dripped on by a heavily rusted valve about it. 74 SOLAS (14) 11-1/13-1 40ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2025
Resolved 10 March 2025
Resolution: Deficiency rectified via class report.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 5 March 2025 Resolved
The Master, Owner, Operator, Agent, or Person in Charge of any vessel equipped with ballast water tanks that operates in the waters of the United States must follow these practices: Remove fouling organisms from the vessel's hull...and dispose of any removed substances in accordance with local, state, and federal regulations. PSCO observed accumulation of barnacles on both port side and stern of the hull. Vessel cleaning in January did not address bio-fouling above present waterline. 33 CFR 151.2050 (f) 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2026
Resolution: See attached class report.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 March 2025 Resolved
The rings, lines, and letters shall be painted in white or yellow on a deck ground or in black on a light ground...The marks shall be plainly visible. PSCO observed both load line marks and drought marks not clearly visible due to heavy rust.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2026
Resolution: See attached class report.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.