MAURY USCG vessel records
← All vessels

SKYWALKER

SKYWALKER is a 2015 freight ship. The Coast Guard has recorded 15 inspections since 2016, most recently in May 2026, along with 3 deficiencies — 1 with no resolution recorded — and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 5 May 2026.

Built
2015
Last inspected
5 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9724740
1371770
Flag
LIBERIA
Maury page id
psix-1371770

Inspections, by type

…with no type recorded4
…past their stated due date1
Years with a record 8 calendar years (2016–2026)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it63056 - Dead Weight, Metric Ton
36396 - Convention (Subpart B), Gross Ton
75086 - Displacement, Metric Ton
21315 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 15

5 May 2026 PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8352580
27 April 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8120820
16 August 2024 Damage Survey · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7977379
28 November 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7600278
15 February 2022 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7396919
20 April 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7168942
12 April 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7173387
6 April 2021 COE-Administrative · Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7169630
24 January 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6614752
22 July 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6217108
9 August 2016 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5966912
23 July 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5950301
30 March 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5843410
29 March 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5842906
23 March 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5839315

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 May 2026 No resolution recorded
Portable fire extinguishing equipment of an approved type suitable for extinguishing fires. PSCO observed a fire extinguisher on the rescue boat with a broken gauge. 74SOLAS(14) II_2/10.3.1 FSS 5.1.2.2.14
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2026 — due date passed with no resolution recorded
Resolution: Ships crew replaced extinguisher with a new one, but didn't have a proper fitting bracket for the new fire extinguisher.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 5 May 2026 Resolved
The international oil pollution prevention certificate shall be drawn up in the form corresponding to the model given in appendix II. PSCO identified the IOPP supplement was missing the throughput of the OWS system. MARPOL I/9.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 5 May 2026
Resolved 5 May 2026
Resolution: Master reached out to class and received an updated IOPP.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 22 July 2017 Resolved
Vessel has a broken ballast water treatment system, but is unable to use it due to a lack of parts available. Sector New Orleans was notified and allowed vessel to make a one time discharge of only that amount reasonably necessary to maintain safety and stability of the vessel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 24 January 2019
Resolution: Deficiency rectified due to submission of class report attesting to receipt of parts and proper repair of ballast water treatment system.

Ownership record