FABIA SCHULTE is a 2015 freight ship. The Coast Guard has recorded 16 inspections since 2016, most recently in December 2025, along with 3 deficiencies and 2 operational controls.
Records from 2016 to 2025. Most recent: inspection, 15 December 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it13691 - Convention (Subpart B), Net Ton 25515 - Convention (Subpart B), Gross Ton 40041 - Dead Weight, Metric Ton 50220 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 16
15 December 2025PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8283495
27 December 2022Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7613267
22 December 2022Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7612221
12 December 2022PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7603775
10 December 2022Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7607817
20 November 2020Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7099303
14 August 2019In-Service Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6783350
13 August 2019Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6782010
12 August 2019Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6781925
6 August 2019Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6765919
22 May 2018ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6414854
7 October 2017Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6283066
25 April 2017ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6126028
23 August 2016COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5980722
17 August 2016Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5975256
2 July 2016Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5926633
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 December 2022Resolved
01: Emergency lighting shall illuminate for a minimum of 3 hours at every muster and embarkation station and over the sides. PSCO witnessed 09 embarkation and over the side lighting unlit. 74 SOLAS (2020) III/43.2.1 (17a.c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2022
Resolved 18 December 2022
Resolution: Vessel submitted class report attesting to satisfactory emergency lighting.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 December 2022Resolved
02: Emergency lighting shall illuminate for a minimum of 18 hours in all service spaces. PSCO witnessed 10 emergency lights extinguished in the service spaces. 74 SOLAS (2020) III/43.2.2 (17a.c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2022
Resolution: Received class report attesting to satisfactory function of emergency lighting.
03: The condition of the ship and it’s equipment shall be maintained to conform with the provisions of the present convention. Regeneration of fuel oil from oil residue only permitted if mentioned on IOPP supplement. Regeneration not approved on IOPP supplement. PSCO observed entries in the O.R.B. for sludge regeneration. MARPOL I Reg 6.4.1 MEPC.1/Circ.736 (16.c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 27 December 2022
Resolution: Received IOPP supplement issued by BV. Regeneration of FO listed as approved means for disposal of sludge.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.