AURORA is a 2016 towing vessel. The Coast Guard has recorded 30 inspections since 2016, most recently in January 2026, along with 15 deficiencies, 2 operational controls and 1 casualty investigation in 2018.
Records from 2016 to 2026. Most recent: inspection, 14 January 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 10 September 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it213 - Convention (Subpart B), Net Ton 185 - Regulatory (Subpart C or D), Net Ton 713 - Convention (Subpart B), Gross Ton 273 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 30
14 January 2026Deficiency Check · Annual Inspection
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 January 2026Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the required portable extinguishers. An additional 40-B portable fire extinguisher was not present in the vicinity of the flammable storage cabinet on the aft deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2026
Resolved 4 February 2026
Resolution: OMO provided objective evidence in way of photo showing a portable fire extinguisher installed in vicinity of Flammable storage cabinet.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2026Resolved
Each remote valve control must be marked in clearly legible letters, at least 1 inch high, indicating the purpose of the valve and the way to operate it. The fuel shutoff valve control for the emergency generator was not labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2026
Resolved 4 February 2026
Resolution: OMO provided objective evidence in way of photo showing the emergency generator fuel shut-off was appropriately labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2026Resolved
Extension cords must not be used as a permanent connection to a source of electrical power; Power strips may not be connected to other adapters (daisy-chained). Multiple overhead light fixtures were daisy chained together after drawing power from an extension cord in the fiddley; An extension cord was daisy-chained to a power strip in the crew mess.
Remove or permanently install the overhead lighting; remove the daisy chained extension cords/strips throughout the ship.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2026
Resolved 4 February 2026
Resolution: OMO provided objective evidence in way of photos showing the previously daisy-chained lighting fixtures have been permanently installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 June 2024Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Both shafts in engine room found leaking an excessive amount near aft bulkhead, approximately 1 gallon per minute. Make proper repairs to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 19 June 2024
Resolution: Accepted video showing small drips from shafts while operating.
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Annual inspection became overdue on 5APR24. Complete required inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 June 2024
Resolution: Completed inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 December 2021Resolved
Essential systems or equipment must be regularly tested
and examined. Tests and examinations must verify that
the system or equipment functions as designed. If a
component is found unsatisfactory, it must be repaired
or replaced. Numerous suction valves in the bilge system
were found to not operate in a manner suitable for use
in an emergency situation. Prove proper operation of the
bilge system in accordance with requirements in
46 CFR 143.245(a) and the table in 46 CFR 143.245(b) by
the next annual inspection or shipyard period, whichever
comes first.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 October 2022
Resolution: Bilge system tested and functions as design.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 January 2021Resolved
EACH TOWING VESSEL MUST HAVE A RELIABLE MEANS OF NOTIFICATION WHEN AN AUXILIARY GENERATOR ENGINE HAS LOW LUBRICATING OIL PRESSURE OR HIGH COOLING WATER TEMPERATURE. THE GENERATOR ENGINES WERE STATED TO NOT HAVE ALARMS FOR THE ABOVE CONDITIONS. ATTENDING MI'S UNABLE TO TEST THE ALARMS DUE TO NEEDING AN ENGINE COMPANY REP.
46CFR143.230(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2021
A VESSEL OF AT LEAST FIVE NET TONS UTILIZED IN COASTWISE TRADE IN THE U.S. SHALL HAVE A VALID CERTIFICATE OF DOCUMENTATION. VESSEL'S C.O.D. WAS EXPIRED.
46CFR67.7
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 January 2021Resolved
AT LEAST TWO LIFEBUOYS ON A VESSEL OF GREATER THAN 26-FT. SHALL HAVE A FLOATING ELECTRIC WATERLIGHT. VESSELS FLOATING WATERLIGHTS FOR THE RING LIFE BUOY'S WERE EXPIRED. **VESSEL IS RESTRICTED FROM OPERATING AT TIMES OF RESTRICTED VISIBILITY**
Action required: 705 - Other - as specified
Resolved 2 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 January 2021Resolved
THE MASTER SHALL ENSURE THAT ALL LIFESAVING EQUIPMENT IS MAINTAINED AND READY FOR USE AT ALL TIMES. THE VESSELS RESCUE BOATS WAS NOT OPERATIONAL.
46CFR141.230
**RESTRICTED TO DOMESTIC VOYAGES**
Action required: 705 - Other - as specified
Resolved 4 January 2022
Resolution: Vessel proved propoer operation of the rescue boat.
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 50% of the vessels that has not obtained a valid COI. The vessel shall be
made available for a Coast Guard COI inspection within 90 Days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the
vessel may no long be permitted to operate.
Action required: 60 - Rectify deficiencies prior to movement
Due 27 October 2020
Resolved 2 June 2021
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 25% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 30 days. If an inspection is not completed prior to this date, the action for this deficiency
shall be changed to a 60 (Rectify deficiencies prior to (movement) and the vessel may no long be permitted to operate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2020
Resolved 29 September 2021
Resolution: Vessel was issued COI by Sector New Orleans.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 December 2019Resolved
Propulsion machinery must be maintained to ensure proper operation and suitable for route and service.
Turbo on main propulsion engine experienced damage during normal operation. Conduct repairs prior to resuming operations; repairs must be verified by attending Marine Inspector.
46CFR143.205(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2019
Resolved 20 December 2020
Resolution: MI attended vessel and cleared inop turbo.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 1 August 2019Resolved
THE COMPANY AND THE SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL SAFETY MANAGEMENT CODE. THE SHIP SHALL BE OPERATED BY A COMPANY HOLDING A DOCUMENT OF COMPLIANCE REFERRED TO IN SOLAS 74 (94 AMEND.) IX/3. BOUCHARD TRANSPORTATION'S DOCUMENT OF COMPLIANCE HAS BEEN REVOKED BY COAST GUARD (CG-CVC) LETTER 16711/SERIAL NO. 209 DATED JULY 31, 2019. THE VESSEL IS RESTRICTED TO DOMESTIC VOYAGES ONLY.
Action required: 702 - Prior to embarking on international voyage
Resolved 5 September 2019
Resolution: Operator received Document of Compliance allowing vessel to transit on international voyages.
Prior to departing Sector New York COTP Zone & within 7 days, conduct post-casualty Sub M survey with Sector New York.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2019
Resolution: Inspectors attended the vessel and conducted satisfactory post-casualty Sub M survey.
27 July 2018Routine · role: Involved in a Marine Casualty · 1 injured · activity 6492215
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
MORTON S. BOUCHARD JR. (2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.