Records in 2021. Most recent: inspection, 6 January 2021.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 6 January 2021
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING VOYAGES, ALL LIFE SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. THE RESCUE BOAT IS INOPERABLE.
SOLAS 74(2014 CONS.) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 January 2021
Resolved 27 January 2021
Resolution: USCG reattented vessel. Witnessed proper function of rescue boat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 January 2021
Resolved
A FIEXED FIRE DETECTION SYSTEM SHALL BE PROVIEDED IN ACCORCANCE WITH THE PROVISIONS OF THIS REGULATION. FIXED FIRE DETECTION SYSTEM IS INOPERABLE.
SOLAS 74 (2004 CONS.) II-2/2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 January 2021
Resolved 27 January 2021
Resolution: USCG reattented vessel. Witnessed proper function of fixed fire detection.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 6 January 2021
Resolved
SUBJECT TO THE PROVISIONS OF REGULATIONS 1/10 PARAGRAPH 5, ANY CERTIFICATE REQUIRED BY THE CONVENTION MUST BE KEPT AVAILABLE IN ITS ORIGINAL FORM ON BOARD THE SHIP. FLAG STATE ENDORESEMENT FOR OFFICERS ARE COPIES.
STCW 1/2.11
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 29 January 2021
Resolved 27 January 2021
Resolution: USCG reattented vessel. Witnessed proper documentation from Flag attesting to having copies onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 January 2021
Resolved
THE CAPACITY OF THE GENERATING SETS SHALL BE SUCH THAT IN THE EVENT OF ANY ONE GENERATING SET BEING STOPPED, IT WILL STILL BE POSSIBLE TO SUPPLY THOSE SERVICES NECESSARY TO PROVIDE NORMAL OPERATIONAL CONDITIONS OF PROPULSION AND SAFETY. ONE GENERATING SET IS INOPERABLE DUE TO EXPANSION TANK MAINTENANCE.
SOLAS 74(2004 CONS.) II-1/41.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 January 2021
Resolved 27 January 2021
Resolution: USCG reattented vessel. Witnessed proper function of generator.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 January 2021
Resolved
EVERY SHIP SHALL BE PROVIDED WITH A MAIN STEERING GEAR AND AUXILIARY STEERING GEAR. THE STARBOARD STEERING PUMP HAS NO SECONDARY PUMP.
SOLAS 74 (2004 CONS.) II-1/29.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 29 January 2021
Resolved 27 January 2021
Resolution: USCG reattented vessel. Witnessed proper function of starboard steering gear pump.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 6 January 2021
Resolved
THE ARRANGEMENTS SHALL ENSURE THAT THE TIGHTNESS CAN BE MAINTAINED IN ANY SEA CONDITION. THE GASKETS ON DECK THE HATCHES ARE MISSING.
ICLL 66 REG 16.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 January 2021
Resolved 27 January 2021
Resolution: USCG reattented vessel. Witnessed proper function and instillation of gaskets on door and hatches.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 January 2021
Resolved
Main steering gear power units shall be capable of being brought into operation from a position on the navigation bridge. The port steering pump cannot be operated from the bridge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 January 2021
Resolved 1 February 2021
Resolution: USCG reattented vessel. Witnessed proper function of port steering pump from bridge as well as auxiliary steering pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 January 2021
Resolved
The capacity of these generating sets shall be such that in the event of any one generating set being stopped it will still be possible to supply those services necessary to provide normal operational conditions of propulsion and safety. The number one generator is inoperable and excessively leaking fuel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 January 2021
Resolved 1 February 2021
Resolution: USCG reattended vessel. Witnessed number 1 generator operating normally with all leaks repaired.