← All vessels
MEDI SYDNEY
MEDI SYDNEY is a 2015 freight ship. The Coast Guard has recorded 8 inspections since 2015, most recently in May 2024, along with 9 deficiencies and 1 operational control.
Records from 2015 to 2024. Most recent: inspection, 10 May 2024.
- Built
- 2015
- Last inspected
- 10 May 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9755816 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
H3HJ
1373204
Flag
PANAMA
—
Maury page id
psix-1373204
Inspections, by type
…with no type recorded1
Years with a record
6 calendar years (2015–2024)
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it81661 - Dead Weight, Metric Ton
43247 - Convention (Subpart B), Gross Ton
27490 - Convention (Subpart B), Net Ton
94361 - Displacement, Metric Ton
43247 - Convention (Subpart B), Gross Ton
27490 - Convention (Subpart B), Net Ton
94361 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 8
10 May 2024
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7900321
24 April 2024
Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7892906
12 April 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7894365
15 March 2022
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7407274
8 September 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6523050
8 June 2017
ISPS II Exam · Ballast Water Examination · Deficiency Check · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6169177
25 March 2016
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5840728
15 November 2015
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5757975
Deficiency record · 9
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 24 April 2024
Resolved
Before the ship leaves port and at all times during the Voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed that the rescue boat davit was inoperable. (74 SOLAS (20) III/20.2)
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 April 2024
Resolved
The purpose of this regulation is to limit the fire growth potential in every space of the ship. For this purpose, means of control for flammable liquids in the space shall be provided. PSCO observed fuel oil soaked lagging on the boiler feed pump and surrounding structural fire protection. (74 SOLAS (20) II-2/5.1.2)
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 April 2024
Resolved
The purpose of this regulation is to limit the fire growth potential in every space of the ship. For this purpose, means of control for flammable liquids in the space shall be provided. PSCO observed oil soaked lagging underneath the waste oil settling tank. (74 SOLAS (20) II-2/5.1.2)
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 24 April 2024
Resolved
Maintenance, testing, and inspections shall be carried out bas4ed on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO observed degradation of on the fire-fighting ensemble. (74 SOLAS (20) II-2/14.2.2.1)
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 April 2024
Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500 L and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned. PSCO observed a quick closing valve on the day tanks blocked open. (74 SOLAS (20) II-2/4.2.2.3.4)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 September 2018
Resolved
0620 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to see without danger to the ship and persons aboard. The starboard side life raft has been altered beyond its last servicing records. SOLAS 74(14)Ch1 Reg11 17ac
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 September 2018
Resolved
0750 Where "A" class divisions are penetrated, such penetrations shall be suitably insulated by extension of the insulation of the same level of insulation. A pipe penetration within the CO2 Room did not have the appropriate level of insulation. SOLAS74(14)ChII-2 Reg 9.3.1; 40ac
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 September 2018
Resolved
0750 Where "B" class divisions are penetrated for the passage of electric cables, pipes, trunks, ducts, ect...arrangements shall be made to ensure that the fire resistance is not impaired. An electrical cable on the bridge lacks proper insulation at the point of penetration.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 8 June 2017
Resolved
The ship was discharging untreated ballast water in U.S.waters. The ship is required to use a BWM system.
33CFR151.2025
prior to discharging ballast water in U.S. waters.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.