Records from 2016 to 2026. Most recent: inspection, 10 July 2026.
Inspection history · 22
10 July 2026
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8432959
1 February 2026
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8304627
1 February 2026
COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8305112
25 June 2025
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8162172
25 June 2024
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7938817
14 January 2024
Deficiency Check · In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7849304
14 January 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7849350
12 January 2024
In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7848932
3 January 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7845708
15 July 2023
Administrative Inspection · COC-CHEM Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7740588
27 March 2022
PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7419243
24 June 2020
PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6977286
20 November 2019
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6859194
13 November 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6854484
13 November 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6855247
16 September 2019
ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6812382
13 March 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6641959
12 March 2019
In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6640742
5 March 2019
COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6634321
2 February 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6348568
16 December 2017
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6323175
6 March 2016
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5823484
01 - Certificates & Documentation › 013 - Documents › P&A manual
Issued 10 July 2026
No resolution recorded
Every ship certified to carry substances of category X, Y, or Z shall have on board a manual approved by the administration. The manual shall have a standard format in compliance with Appendix IV to this Annex. PSCO observed Procedures and Arrangements manual not written in accordance with Appendix IV of Annex II.
MARPOL73/79 Annex II, App. IV, Reg. 14
40 ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 July 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 12 January 2024
Resolved
FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READY FOR IMMEDIATE USE. DURING VIBRATION TESTING OF FIRE PUMPS FOR ABS CONTINUOUS MACHINERY SURVEY, THE DISCHARGE VALVE ON FOAM SYSTEM FAILED CAUSING DISCHARGE OF APPROX 300 l OF FOAM, WHICH EXPANDED AND BROKE A FLANGED PIPE COUPLING ON THE FIREMAIN ON DECK, LOCATED JUST AFT OF #6S CARGO TANKS.
NOTE: VESSEL IS AUTHORIZED LOCAL SHIFTING W/IN THE PORT.
17A
74 SOLAS (CONS 20) II-2/14.2.1.1.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2024
Resolution: Class report provided/visual def check conducted confirming repairs of discharge valve and coupling.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 5 March 2019
Resolved
07102 – Inert Gas System – Nitrogen Generator Systems shall be provided with one or more compressors to generate enough positive pressure to be capable of delivering the total volume of gas required by FSS Code 15.2.2.1.2. During the test of “low feed air”, nitrogen compressor #1 began to smoke and immediately shutdown. After further investigation, compressor #2 and #3 experienced similar problems and all three compressors are now inoperative. Crew suspects the star contactor did not change over to the delta contactor following the “low feed air” test. Vessel is restricted from carrying cargoes required to be inerted until Nitrogen Generator System is repaired to the satisfaction of Coast Guard and Class. 74SOLAS(14)II-2/4.5.5.1.1 & FSS Code 15.2.4.1.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2019
Resolution: Received, reviewed and accepted class and third party technician report to clear deficiency.