MAURY USCG vessel records
← All vessels

B. PACIFIC

B. PACIFIC is a 2015 tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in February 2025, along with 6 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 12 February 2025.

Built
2015
Last inspected
12 February 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 February 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9697296
E5U3218
1373640
Flag
COOK ISLANDS
Maury page id
psix-1373640

Documentation record

Tonnage as PSIX records it5689 - Displacement, Ton
5689 - Convention (Subpart B), Gross Ton
7711 - Dead Weight, Metric Ton
2170 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

12 February 2025 PSC B · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8074549
16 November 2022 PSC B · COC-TVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7595542
7 March 2022 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7401394
6 November 2021 PSC B · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7342233
3 November 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7345071
2 January 2019 Ballast Water Examination · Administrative Inspection · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6602430
17 September 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6542748
15 January 2018 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6337925
20 November 2017 ISPS II Exam · Administrative Inspection · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6307003
7 August 2017 Administrative Inspection · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6233342
6 February 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6083684
29 November 2016 COC-TVE Renew · Deficiency Check · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6048606
9 July 2016 Deficiency Check · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5934598

Deficiency record · 6

Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 20 November 2017 Resolved
0699- Not less than one half of the total number of lifebouys shall be provided with lifebouy self-igniting lights complying with the requirments of paragraph 2.1.2 of the code. Not less than two of these shall also be provided with lifeboy self-activating smoke signals complying with the requirements of paragraph 2.1.3 of the code and be capable of quick release from the navigation bridge. Self-activating smoke signal was found to be discharged with activating line glued back into place. 74SOLAS(14)CH. III/7.1.3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2017
Resolution: DEFICIENCY RECTIFIED BY CLASS, SEE CLASS RECORD SURVEY ATTACHED
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 November 2017 Resolved
1745- 15 PPM ALARM ARRANGEMENTS-OIL FILTERING EQUIPMENT OF THIS REGULATION SHALL BE OF A DESIGN APPROVED BY THE ADMINISTRATION AND SHALL BE SUCH AS WILL ENSURE THAT ANY OILY MIXTURE DISCHARGED INTO THE SEA AFTER PASSING THROUGH THE SYSTEM HAS AN OIL CONTENT NOT EXCEEDING 15 PPM, IN CONSIDERING THE DESIGN OF SUCH EQUIPMENT, THE ADMINISTRATION SHALL HAVE REGARD TO THE SPECIFICATION RECOMMENDED BY THE ORGANIZATION. MEPC.107(49)(4.2.10-1- TO AVOID WILFUL MANIPULATION OF 15 PPM BILGE ALARMS, THE FOLLOWING ITEMS SHOULD BE INCLUDED: EVERY ACCESS OF THE 15 PPM BILGE ALARM BEYOND THE ESSENTIAL REQUIREMENTS OF PARAGRAPH 4.2.8 REQUIRES THE BREAKING OF A SEALL; OIL CONTENT METER SENSOR HOUSING SEAL IS MISSING - MARPOL ANNEX 1 REG. 14.6/ MEPC.107(49)/4.2.10.1
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 20 November 2017
Resolution: RECTIFIED DURING EXAM
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 20 November 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 January 2018
Resolution: Vessel updated Transfer Procedures IAW 33 CFR 155.750
Documentation › Logs/Records › Oil Record Book
Issued 29 November 2016 Resolved
On November 22, 2016, the chief engineer provided an entry in the official oil record book for the use of the oily water separator that exceeds the maximum throughput of the oily water separator system per the approved IOPP certificate. Rectify to the satisfaction of the RO/RSO and Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2016
Resolved 1 December 2016
Resolution: ABS survey report attesting to the condition of the OWS included in documents.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 9 July 2016 Resolved
1710-Each collection and disposal of oil residues shall be fully recorded in the Oil Record Book Part I,so That all entries int he book appropriate to that operation are completed.Collection and disposal of Oil Residues made to E/M Bottom Void Tank were not recorded in Oil Record Book Part 1. 73 MARPOL(2001cons)I/17.4
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 18 July 2016
Resolution: Verified Class IOPP survey attesting to valid ORB.
Operations/Management › Pollution › Removal Methods/Procedures
Issued 9 July 2016 Resolved
1721-After the survey preceding issuance of the International Oil Pollution Certificate, no change shall be made that are covered by the survey, without sanction of the Administration, Use of E/M Bottom Void Tank to stow oil residue represents a change to sludge tank arrangements after conducting of survey. 73 MARPOL (2001 Cons.) I/6.4.2
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 18 July 2016
Resolution: ABS and CG Marine Inspector verified oil water mixture removed and space cleaned.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.