G.L. 58 is a 1955 industrial vessel. The Coast Guard has recorded 15 inspections since 2016, most recently in September 2024, along with 13 deficiencies.
Records from 2016 to 2024. Most recent: inspection, 25 September 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 13 March 2026 · expires 30 April 2027
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1029 - Simplified, Gross Ton 1029 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
25 September 2024Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8005318
2 October 2023Deficiency Check · Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7798246
26 May 2023Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7696996
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2024Resolved
Each cable installation must meet Sections 6, of IEEE 45.8-2016 (incorporated by reference; see § 110.10-1 of this subchapter). USCG MI's observed multiple cable runs not secured properly. Areas identified were: Crane machinery room switchboard area, forward starboard machinery room overhead, and generally throughout the machinery room. Properly secure all cables IAW IEEE to satisfaction of USCG.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2024
Resolved 23 October 2024
Resolution: All corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 September 2024Resolved
Piping systems for ships and barges must be designed, constructed, and inspected in accordance with ASME B31.1 (incorporated by reference; see § 56.01-2), as limited, modified, or replaced by specific requirements in this part.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2024
Resolved 23 October 2024
Resolution: All corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 October 2023Resolved
All safety and relief valves for use on pressure vessels or piping systems shall be designed to meet the protection and service requirements for which they are intended and shall be set to relieve at a pressure which does not exceed the “maximum allowable working pressure” of the pressure vessel or piping system. The crane engine room air receiver pressure relief valve is set to 225 psi & the MAWP of the air receiver tank is 200 psi.
46CFR54.15-10(a)
Action required: 705 - Other - as specified
Due 9 October 2023
Resolved 12 October 2023
Resolution: Picture of relief valve installed received.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 2 October 2023Resolved
A ship of 100 gross tons or more constructed before July 1, 1974, and a ship of 100 or more but less than 300 gross tons constructed after June 30, 1974 must: Meet paragraph (a)(1) of this section; or (2) Equip each
fuel oil or bulk lubricating oil tank vent, overflow,
and fill pipe during oil transfer operations with a portable container of at least a 5 U.S. gallon capacity;
or (3) If the ship has a fill fitting for which
containment is impractical, use an automatic back
pressure shut-off nozzle. Fuel transfer station
containment coaming drain plug could not be threaded into containment.
33CFR155.320(b)
Action required: 705 - Other - as specified
Due 9 October 2023
Resolved 10 October 2023
Resolution: Received objective evidence of coaming plugs installed. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 2 October 2023Resolved
Each liferaft must be stowed to permit manual release from its securing arrangements. The port side liferaft pelican hook is corroded and siezed closed.
46CFR199.130(c)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2023
Resolved 8 November 2023
Resolution: Vessel crew replaced port side pelican hook, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 October 2023Resolved
Each generator arranged for parallel operation must have reverse-power or reverse-current trips. Operator could not demonstrate this function.
46CFR111.12-11(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 8 November 2023
Resolution: MI's observed the designated vessel rep and catapiller tech complete reverse power relays on both generators, all sat.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 2 October 2023Resolved
The operating levers of each quarter-turn (rotary) valve must be parallel to the fluid flow when open and perpendicular to the fluid flow when closed. The forward crane generator fuel cutoff valve nearest the fuel pump was not installed as designed and had a pair of vice grips as handle.
46CFR56.20-9(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2023
Resolved 8 November 2023
Resolution: Vessel crew replaced valve handle in kind.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 October 2023Resolved
Each vessel must carry not less than 12 rocket parachute flares approved under approval series 160.136. Vessel only had 8 flares onboard.
46CFR199.60(c)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2023
Resolved 8 November 2023
Resolution: MI witnessed 12 approved flares on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 October 2023Resolved
Openings for fill and vent pipes must be on the topmost surface of a tank. There must be no openings in the bottom, sides, or ends of a tank except as follows: The opening for the fuel supply piping is not restricted to the top of the tank. MI observed a small diesel fuel leak coming from vessel’s day tank at the fill opening.
46CFR58.50-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2023
Resolved 8 November 2023
Resolution: Vessel crew changed fittings going into top flange hatch. MI inspected the non-integral day tank and observed no leakage, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 October 2023Resolved
Previously installed extinguishers with extinguishing capacities smaller than what is required in table 95.50-10(a) of this subpart need not be replaced and may be continued in service so long as they are maintained in good condition to the satisfaction of the [name withheld] observed two portable fire extinguishers not secured in their approved brackets & just sitting on deck.
46CFR95.50-80(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2023
Resolved 8 November 2023
Resolution: MI observed both portable fire extinguishers secured in their approved bracket, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2023Resolved
Pressure vessels shall be designed, constructed, and inspected in accordance with section VIII of the ASME Boiler and Pressure Vessel Code (incorporated by reference, see 46 CFR 54.01–1), as limited, modified, or replaced by specific requirements in this part. The provisions in the appendices to section VIII of the ASME Boiler and Pressure Vessel Code are adopted and shall be followed when the requirements in section VIII make them mandatory. For general information, table 54.01–2(a) lists the various paragraphs in section VIII of the ASME Boiler and Pressure Vessel Code that are limited, modified, or replaced by regulations in this part. Air Receiver in Crane had visible wastage, scaling corrosion. Provide ASME U1A form with serial number for that receiver that shows allowable corrosion allowance or replace.
46CFR54.01-2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 8 November 2023
Resolution: Vessel crew replaced pressure vessel. MAWP is 200.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 July 2020Resolved
Lifebuoys must have attachments and fittings resistant
to UV light. Current grab line is deteriorated and needs
replacing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2020
Resolved 11 July 2020
Resolution: Replaced line.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 July 2020Resolved
Manholes and flush scuttles in position 1 or 2 or within
superstructures other than enclosed superstructures shall be closed by substantial covers capable of being made watertight. Identified 04 manhole covers with missing hardware. Replace with the required hardware.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2020
Resolved 11 July 2020
Resolution: Installed nuts.