MAURY USCG vessel records
← All vessels

KNOKKE

KNOKKE is a 2016 tank ship. The Coast Guard has recorded 30 inspections since 2016, most recently in December 2025, along with 2 deficiencies and 4 operational controls.

Records from 2016 to 2025. Most recent: inspection, 1 December 2025.

Built
2016
Last inspected
1 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9687497
1374217
Flag
BELGIUM
Maury page id
psix-1374217

Inspections, by type

…with no type recorded11
Years with a record 6 calendar years (2016–2025)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it29478 - Dead Weight, Metric Ton
41489 - Displacement, Metric Ton
26261 - Convention (Subpart B), Gross Ton
26261 - Regulatory (Subpart C or D), Gross Ton
7878 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 30

1 December 2025 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8275456
22 June 2025 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8164311
9 May 2025 Deficiency Check · PSC B · COC-GAS Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8131528
20 February 2025 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8081651
20 February 2025 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8082194
2 January 2025 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8056764
10 December 2024 COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8045744
1 October 2024 COE-Administrative
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8012297
1 October 2024 COE-Administrative
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8012307
16 July 2024 COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7959340
1 February 2024 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7859159
27 January 2024 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7856689
12 September 2023 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7787574
12 September 2023 Bulk Liquid Transfer Monitor
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7789966
12 September 2023 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7790192
28 July 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7754886
5 June 2023 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7704103
4 June 2023 PSC B · COC-GAS Renew · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7702858
8 March 2023 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7648259
7 March 2023 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7644227
6 December 2022 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7604996
27 November 2022 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7598189
24 November 2022 PSC B · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7598352
24 November 2022 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7599317
20 August 2022 In-Service Inspection · PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7530513
20 August 2022 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7539040
22 May 2022 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7452766
14 May 2021 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7187279
17 July 2016 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5934067
12 July 2016 ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5937736

Deficiency record · 2

09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 9 May 2025 Resolved
Mechanical ventilation inlets and outlets should be arranged to ensure sufficient air movement through the sapce to avoid the accumulation of flammable or toxic vapours and to ensure a safe working environment. PSCO observed ventilation for airlock and motor room to be insufficient. 74 SOLAS (20) VII/11.1 IGC Code (1993) 12.1.2 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2025
Resolved 29 May 2025
Resolution: RCVD class report LR attesting to an overhaul of the ventilation fans. LR attested to the proper ventilahation within the airlock.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 24 November 2022 Resolved
Oil filtering equipment referred to in paragraph 1 of this regulation shall be of a designed and approved type by the administration...shall have regard to the specification reccomonded by the organization (MEPC.107(49)). The oil content meter display is malfunctioning, data history logging requirements in MEPC.107(49) cannot be verified. The OWS functions as intended. The vessel may not utilize the OWS to discharge while in U.S. waters. MARPOL I/14.6, Code 50AC (Class and USCG acceptance for corrective action).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2022
Resolved 6 December 2022
Resolution: New oil content meter display was ordered and now has been installed. The display function is found in order.

Ownership record