Records from 2013 to 2024. Most recent: inspection, 11 March 2024.
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 April 2018
Resolved
Fwd Compt bilge alarm and low level hyd. alarm only operating as visible indicators. Repair audible alarms
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Electrical › Electric Supply System (service) › Cable
Issued 10 April 2018
Resolved
Loose and dead end wiring found under console in wheelhose. Remove/repair as necessary.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Lifesaving › Lifefloat › Paddle
Issued 10 April 2018
Resolved
Replace life float paddles and lanyards as necessary.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Electrical › Electric Supply System (service) › Cable
Issued 10 April 2018
Resolved
Wire runs in engine room need proper metal supports. Plastic tie wraps not sufficient.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 April 2018
Resolved
Clean STBD battery box. Bottom filled with liquid.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Electrical › Electric Supply System (service) › Cable
Issued 10 April 2018
Resolved
Remove/ replace dead end wires above battery box.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 10 April 2018
Resolved
Sewage treatment pump not properly mounted. Secure as per manufactureres instructions.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 10 April 2018
Resolved
Port Main clutch cable needs proper nut and bolt for mounting. repair/replace as necessary.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 April 2018
Resolved
Secure lid to distribution box and label circuit breakers appropriately.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Construction/Loadline › Hull › Hull Plating
Issued 24 May 2016
Resolved
Vessel taking on water in two locations within the engine room. Found one crack with water intrusion in forward part of the engine room, port of centerline, near recent hull insert. Another crack was found underneath the port-side fuel tank. Emergency drydock required. 12"x12" grid UT shots ordered in surrounding areas until shots are within the 10% wastage allowance.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2016
Resolution: Inspected NDT on hull inserts. All Sat.
Stability › Watertight Integrity › General
Issued 24 May 2016
Resolved
WATERTIGHT COMPARTMENTS FOUND MISSING WATERTIGHT ACCESS PLATES. 46 CFR 171.111(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2016
Resolution: Plates properly installed.
Fire Fighting › Fire Pumps › Capacity
Issued 24 May 2016
Resolved
FIRE PUMP DOES NOT PRODUCE AN EFFECTIVE STREAM. 14PSIG DURING INSPECTION. 46 CFR 181.10-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2016
Resolution: Installed larger fire pump motor, all sat.
Navigation › Piloting/Steering › Marine Charts
Issued 24 May 2016
Resolved
MISSING ALL PUBS,CHARTS 46 CFR 184.420
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Provided
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 24 May 2016
Resolved
NO DEVIATOPN TABLE ONBOARD. 33 CFR 164.35(c)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 16 June 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 24 May 2016
Resolved
ALCOHOL TEST STRIPS ONBOARD EXPIRED IN 2013. 46 CFR 4.06-15(a)3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Provided
Construction/Loadline › Structures › Deck Plating
Issued 24 May 2016
Resolved
REPLACE WASTED DECK METAL. TWO HOLES FOUND IN THE DECK UNDER THE DECK BOARDS. 46 CFR 176.800
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2016
Resolution: Completed and inspected.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 24 May 2016
Resolved
PROVIDE NON-CONDUCTIVE HAND RAIL & MAT IN FRONT OF SWITCHBOARD. 46 CFR 183.10-15(b)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Installed
Engineering › Fuel Oil Service System › Piping
Issued 24 May 2016
Resolved
REPAIR FUEL LEAKS ON FUEL FITLER PIPING. INSTLL PLUG AT THE BOTTOM OF FILTER 46 CFR 182.455(a)3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2016
Resolution: corrected
Stability › Watertight Integrity › General
Issued 24 May 2016
Resolved
MAKE ALL WATERTIGHT HATCHES OPERATIONAL AND WATER TIGHT. 46 CFR 179.320
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2016
Resolution: Corrected
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 24 May 2016
Resolved
PROVIDE U1A FORM FOR NEW PRESSURE VESSEL SHOWING BUILT FOR MARINE USE,NO RELIEF VALVE INSTALLED. 46 CFR 50.25-5
50.15-10
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: U1A provided and relief valve installed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 24 May 2016
Resolved
SEWAGE OVERBOARD VALVE AND CONNECTION SHAL BE METAL. 46 CFR 182.40-1 (a)3
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Correct valve installed
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 24 May 2016
Resolved
PROPERLY BOND GENSET GAUGES. 46 CFR 138.01-15
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Grounded properly
Communications › Public Address System › Broadcast Location
Issued 24 May 2016
Resolved
PROVIDE PUBLIC ADDRESS SYSTEM. NONE ONBOARD. 46 CFR 184.610
184.115
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Provided and tested.
Communications › Visual Communication › Signalling Lamp
Issued 24 May 2016
Resolved
PROVIDE REQUIRED DAY SHAPES. 3 BALLS 1 DIAMOND. NONE ONBOARD. NAVRULES RULE 20
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Provided
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 24 May 2016
Resolved
PROVIDE TWO PORTABLE LIGHTS. 46 CFR 183.430
183.115(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 25 May 2016
Resolution: PROVIDED
Lifesaving › Lifefloat › Float Free
Issued 24 May 2016
Resolved
MAKE LIFE FLOAT FLOAT FREE. 46 CFR 180.137
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2016
Resolution: Rack reconfigured
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2016
Resolved
PROVIDE COMPLETE FIRST AID KIT. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Provided
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 24 May 2016
Resolved
MAKE TILT ALARM AND DEAD MAN FUCTION OPERATIONAL. NVIC 8-91
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2016
Resolution: Fixed and tested.