L/B 102 SELECT is a 1975 offshore supply vessel. The Coast Guard has recorded 6 inspections since 2016, most recently in March 2024, along with 28 deficiencies, 2 operational controls and 1 casualty investigation in 2013.

Records from 2013 to 2024. Most recent: inspection, 11 March 2024.

Built
1975
Last inspected
11 March 2024
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 March 2024
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP4674
137426
Flag
UNITED STATES
Maury page id
psix-137426

Documentation record

Registered dimensions (L × B × D)57.0 ft × 23.8 ft × 5.2 ft
Registered tonnagegross 82 / net 78
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOASTAL CONSTR & SHPYRD · GOLDEN MEADOW, LA, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBELLE CHASE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 July 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Regulatory (Subpart C or D), Gross Ton
78 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 6

11 March 2024 Drydock Exam · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7877502
29 September 2023 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7814994
23 January 2019 COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6614201
9 March 2018 Examination of Repairs · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6369189
16 February 2017 Annual Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6088782
24 May 2016 Damage Survey · Drydock Exam · Administrative Inspection · Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5880253

Deficiency record · 28

Communications › Alarms/Indicators › Bilge Alarm
Issued 10 April 2018 Resolved
Fwd Compt bilge alarm and low level hyd. alarm only operating as visible indicators. Repair audible alarms
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Electrical › Electric Supply System (service) › Cable
Issued 10 April 2018 Resolved
Loose and dead end wiring found under console in wheelhose. Remove/repair as necessary.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Lifesaving › Lifefloat › Paddle
Issued 10 April 2018 Resolved
Replace life float paddles and lanyards as necessary.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Electrical › Electric Supply System (service) › Cable
Issued 10 April 2018 Resolved
Wire runs in engine room need proper metal supports. Plastic tie wraps not sufficient.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 April 2018 Resolved
Clean STBD battery box. Bottom filled with liquid.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Electrical › Electric Supply System (service) › Cable
Issued 10 April 2018 Resolved
Remove/ replace dead end wires above battery box.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 10 April 2018 Resolved
Sewage treatment pump not properly mounted. Secure as per manufactureres instructions.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 10 April 2018 Resolved
Port Main clutch cable needs proper nut and bolt for mounting. repair/replace as necessary.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 April 2018 Resolved
Secure lid to distribution box and label circuit breakers appropriately.
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 11 June 2018
Resolution: Repairs completed and verified satisfactory.
Construction/Loadline › Hull › Hull Plating
Issued 24 May 2016 Resolved
Vessel taking on water in two locations within the engine room. Found one crack with water intrusion in forward part of the engine room, port of centerline, near recent hull insert. Another crack was found underneath the port-side fuel tank. Emergency drydock required. 12"x12" grid UT shots ordered in surrounding areas until shots are within the 10% wastage allowance.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2016
Resolution: Inspected NDT on hull inserts. All Sat.
Stability › Watertight Integrity › General
Issued 24 May 2016 Resolved
WATERTIGHT COMPARTMENTS FOUND MISSING WATERTIGHT ACCESS PLATES. 46 CFR 171.111(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2016
Resolution: Plates properly installed.
Fire Fighting › Fire Pumps › Capacity
Issued 24 May 2016 Resolved
FIRE PUMP DOES NOT PRODUCE AN EFFECTIVE STREAM. 14PSIG DURING INSPECTION. 46 CFR 181.10-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2016
Resolution: Installed larger fire pump motor, all sat.
Navigation › Piloting/Steering › Marine Charts
Issued 24 May 2016 Resolved
MISSING ALL PUBS,CHARTS 46 CFR 184.420
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Provided
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 24 May 2016 Resolved
NO DEVIATOPN TABLE ONBOARD. 33 CFR 164.35(c)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 16 June 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 24 May 2016 Resolved
ALCOHOL TEST STRIPS ONBOARD EXPIRED IN 2013. 46 CFR 4.06-15(a)3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Provided
Construction/Loadline › Structures › Deck Plating
Issued 24 May 2016 Resolved
REPLACE WASTED DECK METAL. TWO HOLES FOUND IN THE DECK UNDER THE DECK BOARDS. 46 CFR 176.800
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2016
Resolution: Completed and inspected.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 24 May 2016 Resolved
PROVIDE NON-CONDUCTIVE HAND RAIL & MAT IN FRONT OF SWITCHBOARD. 46 CFR 183.10-15(b)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Installed
Engineering › Fuel Oil Service System › Piping
Issued 24 May 2016 Resolved
REPAIR FUEL LEAKS ON FUEL FITLER PIPING. INSTLL PLUG AT THE BOTTOM OF FILTER 46 CFR 182.455(a)3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2016
Resolution: corrected
Stability › Watertight Integrity › General
Issued 24 May 2016 Resolved
MAKE ALL WATERTIGHT HATCHES OPERATIONAL AND WATER TIGHT. 46 CFR 179.320
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2016
Resolution: Corrected
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 24 May 2016 Resolved
PROVIDE U1A FORM FOR NEW PRESSURE VESSEL SHOWING BUILT FOR MARINE USE,NO RELIEF VALVE INSTALLED. 46 CFR 50.25-5 50.15-10
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: U1A provided and relief valve installed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 24 May 2016 Resolved
SEWAGE OVERBOARD VALVE AND CONNECTION SHAL BE METAL. 46 CFR 182.40-1 (a)3
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Correct valve installed
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 24 May 2016 Resolved
PROPERLY BOND GENSET GAUGES. 46 CFR 138.01-15
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Grounded properly
Communications › Public Address System › Broadcast Location
Issued 24 May 2016 Resolved
PROVIDE PUBLIC ADDRESS SYSTEM. NONE ONBOARD. 46 CFR 184.610 184.115
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Provided and tested.
Communications › Visual Communication › Signalling Lamp
Issued 24 May 2016 Resolved
PROVIDE REQUIRED DAY SHAPES. 3 BALLS 1 DIAMOND. NONE ONBOARD. NAVRULES RULE 20
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Provided
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 24 May 2016 Resolved
PROVIDE TWO PORTABLE LIGHTS. 46 CFR 183.430 183.115(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 25 May 2016
Resolution: PROVIDED
Lifesaving › Lifefloat › Float Free
Issued 24 May 2016 Resolved
MAKE LIFE FLOAT FLOAT FREE. 46 CFR 180.137
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2016
Resolution: Rack reconfigured
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2016 Resolved
PROVIDE COMPLETE FIRST AID KIT. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 June 2016
Resolution: Provided
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 24 May 2016 Resolved
MAKE TILT ALARM AND DEAD MAN FUCTION OPERATIONAL. NVIC 8-91
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2016
Resolution: Fixed and tested.

Casualty record · 1

5 December 2013Routine · role: Acknowledged Pollution Source · activity 4788041