Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it606 - Convention (Subpart B), Gross Ton 531 - Regulatory (Subpart C or D), Gross Ton 181 - Convention (Subpart B), Net Ton 531 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 4
20 August 2025Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8208318
17 June 2024Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7936768
14 May 2024COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7911670
31 August 2021COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7301298
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 14 May 2024Resolved
All remote fuel shutoffs (04) were found inoperable at the forward and starboard pull stations on the vessel.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 May 2024
Resolution: Fuel shutoff's rebuilt with new seals and new stainless lines.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 May 2024Resolved
Vessel does not have the correct number of visual distress signals. Upon inspection, only three day signals (smoke) were carried onboard. Vessel needs three night signals to meet minimum requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 14 June 2024
Resolution: Handheld flares (x3) purchased and installed onboard.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 14 May 2024Resolved
Upon inspection it was found that no records were being kept for steering gear, signaling whistle, propulsion control, towing gear, navigation lights, nav equipment, and communications system tests. Operator explained that tests are performed but not recorded. Vsl shall ensure tests are recorded as appropriate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 14 June 2024
Resolution: Vessel updated procedures to capture/log equipment tests.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 14 May 2024Resolved
Fire drills are not being recorded for each monthly drill. Found recordkeeping to be sporadic with some months missing. No records of a fire drill available within two months from date of inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 14 June 2024
Resolution: Vessel conducted fire drill and is now logging the drill correctly.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 31 August 2021Resolved
The Coast Guard Light List was found to be outdated (2015). Replace existing Light List with most current edition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 14 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 August 2021Resolved
Relief valves on the #1 & #2 air receivers were found to be last tested in 2014. Complete relief valve testing on both air receivers. Testing is conducted at a rate of twice every five years with with no more than three years elapsing since last test.
*IAW the table found in 46 CFR 143.245(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 14 May 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 31 August 2021Resolved
The means of escape located at the forward end of the tank room requires a special tool to open the hatch. The placement of this tool was found unmarked. To aid in emergency egress, ensure appropriate marking is posted emphasizing the tool's location and use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 14 May 2024
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 31 August 2021Resolved
Fire extinguishers were found to have not been inspected at the appropriate interval. Ensure all hand-portable fire extinguishers are inspected and continue at annual intervals.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 14 May 2024
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 31 August 2021Resolved
The fixed fire-extinguishing system was found to have not been inspected/tested within an annual interval. Ensure the fixed CO2 system is inspected/tested and continue at an annual interval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 14 May 2024
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 31 August 2021Resolved
Fire-fighting drills were not being recorded or conducted at a monthly interval. Conduct a fire-fighting drill with all crewmembers and continue at monthly intervals.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 14 May 2024
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 31 August 2021Resolved
Emergency drills and instruction (not including fire-fighting) were not found to be not recorded in the TVR and/or logbook. Ensure all appropriate emergency drills and instruction is completed no less than at an annual interval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 14 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 31 August 2021Resolved
The life float located on the vessel's stern was found to have the outer layer missing and damaged in enough areas to allow substantial water intrusion and increased deterioration. Repair (IAW manufacturer's instruction) or replace the existing life float.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 14 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 August 2021Resolved
Vessel has onboard 10 type I PFD's. 12 are required, with 10 being allocated for each crewmember and 02 provided within the pilothouse (normally manned watch station). Ensure 12 Type I PFD's are onboard in ready condition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 14 May 2024
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.