DOLE PACIFIC is a 2015 freight ship. The Coast Guard has recorded 17 inspections since 2016, most recently in April 2026, along with 9 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 20 April 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it27513 - Dead Weight, Ton 39442 - Displacement, Ton 26046 - Convention (Subpart B), Gross Ton 8547 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 17
20 April 2026PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8352661
1 April 2026MARPOL Annex I Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8340152
22 July 2025PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8191808
27 April 2025Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8126329
27 April 2025Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8271646
31 January 2025PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8073022
9 September 2024PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7995630
20 August 2024PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7980664
11 December 2023PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7834607
24 May 2022PSC B · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7453769
6 May 2021Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7193840
2 November 2020PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7085371
10 June 2019Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6718078
29 April 2019Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6670545
16 April 2018ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6389166
4 April 2017Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6113149
23 March 2016Random ISPS/MTSA/PSC
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5839022
MARPOL I/14.7
Oil filtering equipment referred to in paragraph 6 of this regulation. In addition, it shall be provided with alarm arrangements to indicate when this level cannot be maintained. The electrode sensor on the OWS is being by-passed to run the system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2026
Resolution: component replaced and certified by class report
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 1 April 2026Resolved
MARPOL I/17.1
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the ORB. PSCO observed not all operations of the OWS was properly written in the ORB part 1.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2026
Resolution: Class issued training to engineering officers on proper completion of oil record book entries
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 1 April 2026Resolved
SOLAS 74 (2024 cons.) IX/3.1 ISM code 1.4
Every company should develop, implement and maintain a safety management system which includes: intructions and procedures to ensure protection of the environment. PSCO observed no SMS
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2026
Resolution: Class attended ship and ensured a new section of the SMS was drafted in regards to proper operation of the OWS.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 11 September 2024Resolved
The company should establish procedures to ensure that the ship is maintained in confromity with the provisions of the relevant regulations and any additional requirements established by the company. Vessel failed to implement their SMS by not reporting to the vessel's DVM. SMS states, 10.1.5, unexpected maintenance items are to be reported to the DVM as soon as possible, with consideration given to urgency.
74 SOLAS (20) XI/4.1
ISM CODE 10.1
Action required: 10 - Deficiency Rectified
Resolved 11 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2024Resolved
The condition of the Ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed BWTS valve BA088 not properly functioning. PSCO observed fresh water generator outtake valve not installed due to maintenance. this is the only means to create fresh water while at sea.
74 SOLAS (20) 1/11 10c
Action required: 10 - Deficiency Rectified
Resolved 11 September 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 20 August 2024Resolved
04114 "Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the administration with a stored energy capability of at least three consecutive starts. A second source of energy shall be provided." A second source of energy was under repair and not functional. 74 SOLAS (20) II-1/44.2 17ac
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 3 September 2024
Resolved 20 August 2024
Resolution: "Now confirmed by remote lifestreaming connection that new bateries were correctly installed
and tested to provide at least three consecutive starts. Also spring stating mean tested as
second mean of starting. All satisfactory and considered in order."
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 20 August 2024Resolved
15113 "Every company should develop, implement, and manintain a safety management system which includes the following functional requirement instructions and procedures. SMS cybersecurity plan requires information security." Vessel failed to implement its SMS with respect to cyber risk management. Vessel posted username and passwords and multiple terminals. NOTE: Vessel should conduct internal audit to ensure SMS cybersecurity is implemented. 74 SOLAS (2) IX 13.1, ISM Code 1.4. 40ac
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 September 2024
Resolved 20 August 2024
Resolution: "Reported that USER Name & Password removed/erased from whiteboard. Confirmed and
showed during lifestreaming connection. The company duly noted and confirmed to
arrang internal audit as proposed"
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 August 2024Resolved
13103 "The machinery shall be of a design and construction adequate for the service for which they are intended and shall be so installed." 2 lube oil sensors on the main service generators were broken.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2024
Resolved 20 August 2024
Resolution: "Reported that the screw was fixed immediately and shown to USCG Officer. Now
verified in remote lifestreaming connection and photos that if its fitted correctly.
Confirmed and considered in order."
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 December 2023Resolved
Deficiency Code - 13199, Deficiency Category - Other (machinery), "The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. The design shall have regard to materials used in construction, the purpose for watch the equipment is inteded, the working conditions to which it will be subjected and the environmental conditions on board." Excessive hydraulic fluid leaked from the steering gear assembly. SOLAS 74 (20) II-1/26.1-15ac.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 December 2023
Resolution: recevied class report attesting to deficiency.