MAURY USCG vessel records
← All vessels

SWIFT YANGZHOU

SWIFT YANGZHOU is a 2015 freight ship. The Coast Guard has recorded 6 inspections since 2016, most recently in March 2022, along with 5 deficiencies and 1 operational control.

Records from 2016 to 2022. Most recent: inspection, 29 March 2022.

Built
2015
Last inspected
29 March 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 March 2022
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9502611
1374288
Flag
HONG KONG
Maury page id
psix-1374288

Documentation record

Tonnage as PSIX records it27819 - Convention (Subpart B), Net Ton
79489 - Dead Weight, Metric Ton
93374 - Displacement, Metric Ton
43498 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 6

29 March 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7420698
3 May 2019 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6676022
28 March 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6632005
10 October 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6278465
7 October 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6283144
25 September 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6008717

Deficiency record · 5

08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 29 March 2022 Resolved
74SOLAS(09)II-2/ 7.3.2 The function of fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature, or smoke or aerosol particles having the appropriate range of density or particle size, or other phenomena associated with the detector is designed to respond. Crew did not use appropriate tools for testing the flame sensor.
Action required: 10 - Deficiency Rectified
Resolved 29 March 2022
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 28 March 2019 Resolved
07103 Division - decks, bulkheads and penetrations. Structural fire protection, including fire-resisting divisions and penetrations of these divisions, shall be kept in good working order so as to ensure their required performance. If a fire occurs due to work done to a bulkhead, the insulation on the "A" Class division overhead appears compromised in the cable space on the "D" Deck. 74 SOLAS (09) 11-2/14.2.1.1.1 - 50ac
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2019
Resolved 2 May 2019
Resolution: Received, reviewed and accepted class report from DNV-GL stating the deficiency was rectified. Insulation and sealing of cable penetrations inside cable space on D-Deck were rectified and verified by attending surveyor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 March 2019 Resolved
03199 Other (load lines) The mark of the authority by whom the load lines are assigned may be indicated alongside the load line ring. The load line shows the mark of ABS and the current International Load Line Certificate is issued by DNV-GL. ICLL Reg. 7 - 50ac
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2019
Resolved 2 May 2019
Resolution: Received, reviewed and accepted class report from DNV-GL stating the deficiency was rectified. It has been verified that the previous load line mark of ABS was removed and VL was permanently marked on both sides of shell plate.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 10 October 2017 Resolved
1499-Machinery- The machinery shall be of a design and construction adequate for which they are intended and shall be so installed and protected to reduce to a minimum any danger to persons on board. Attending PSCO discovered evidence of an exhaust leakon the main engine posing a potential hazard to the engineering crew. 74SOLAS14 II-1/26 17ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 13 October 2017
Resolution: MSU Baton Rouge received a class report from DNV-GL stating that the exhaust leak has be repaired.
Deck/Cargo › Marine Portable Tanks › Framework
Issued 10 October 2017 Resolved
9800-Deck/cargo- Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place. Attending PSCO observed numerous oxygen and acetylene compressed gas cylinders in the deck lockers that were not properly placed in a rack and missing the valve protection cap.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 October 2017
Resolved 28 March 2019
Resolution: Corrective action was verified during the course of PSC Exam. Cylinders were properly bracketed and valve protection caps properly applied.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.