MAYARO is a 2015 tank ship. The Coast Guard has recorded 17 inspections since 2016, most recently in February 2026, along with 4 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 23 February 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it21129 - Convention (Subpart B), Gross Ton 7679 - Convention (Subpart B), Net Ton 30940 - Dead Weight, Ton 39470 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 17
23 February 2026PSC B · COC-CHEM Renew
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8311366
22 January 2026Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8300604
16 April 2025Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8113088
26 March 2025COC-CHEM Annual · PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8096173
5 March 2024COC-CHEM & TVE Renew · Administrative Inspection · PSC B
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 26 March 2025Resolved
THE IOL DISCHARGE MONITORING AND CONTROL SYSTEM SHALL BE DESIGNED AND INSTALLED IN COMPLIANCE WITH THE GUIDELINES AND SPECIFICATIONS FOR IOL DISCHARGE MONITORING AND CONTROL SYSTEMS FOR OIL TANKERS DEVELOPED BY THE ORGANIZATION. COMPANY REPORTED ODME WAS INOPERABLE. CLASS SURVEY REQUIRED FOLLOWING REPAIRS TO OBSERVE FULL FUNTIONALITY OF ODME.
MARPOL ANN I CH.4 REG 31.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2025
Resolved 17 April 2025
Resolution: ODME pump shaft seal was replaced and tested satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 3 November 2020Resolved
The means of embarkation and disembarkation required in paragraph 1 shall be constructed and installed based on the guidelines developed by the Organization. PSCO observed damage on port side embarkation ladder after contact with another vessel.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2020
Resolved 30 January 2021
Resolution: Repairs made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 November 2020Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fir to proceed to sea without danger to the ship or persons onboard. PSCO observed a faulty PCB on main engine that caused slow down due to faulty temperature alarm indication. Ship personnel conducted replacement of circuit board. Awaiting class for satisfactory testing of the system.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 November 2020
Resolution: Received class report from NKK attesting to the successful replacement of the faulty temperature sensor
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 16 January 2018Resolved
1850:For Tankers 20000 DWT and upwards, protection of the cargo tanks shall be a fixed Inert Gas System IAW the requirement of the FSS code. Vessels O2 sensor on the Nitrogen system is inoperable and unable to provide accurate percentage being supplied to cargo area. Vessel is not authorized to load any annex I or Annex II cargos that are required to be inerted. SOLAS 74a (09 cons) II-2/5.5.1.1 a,c
Action required: 705 - Other - as specified
Resolved 23 January 2018
Resolution: Received, reviewed, and accepted a class report from NKK stating the deficiency was rectified. The report stated that the O2 sensor for the Nitrogen Generator was replaced with a new one, tested, and found to be working satisfactorily.