JAMES HENRY

JAMES HENRY is a 2015 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2017, most recently in December 2025, along with 34 deficiencies.

Records from 2017 to 2025. Most recent: inspection, 15 December 2025.

Built
2015
Last inspected
15 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDI5012
1374801
Flag
UNITED STATES
Maury page id
psix-1374801

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 8 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)47.0 ft × 17.0 ft × 8.5 ft
Registered tonnagegross 45 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderB & T WELDING LLC · BOOTHVILLE, LA, UNITED STATES · built 2015
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 December 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton
36 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

15 December 2025 COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8269909
12 December 2024 Annual Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8046690
14 February 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7865419
21 October 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7581628
29 December 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7366034
12 November 2020 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7093948
10 January 2020 Drydock Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6867924
14 February 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6626042
9 March 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6357862
25 January 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6075147

Deficiency record · 34

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 February 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure. MI observed cracks in the steering compartment on P/S cleat pedestals, both rudder posts, STBD rudder post frame at the stringer, rudder post transverse frame, and overhead. Make repairs to the satisfaction of the Marine Inspector. 46CFR176.802(a) 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2025
Resolved 25 February 2025
Resolution: Received photos of satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 February 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the inspection of all generators. MI observed no generator electrical output and the distribution panel disconnected. Make repairs to the satisfaction of the Marine Inspector. 46CFR176.806(e) Prior to generator operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2025
Resolved 25 February 2025
Resolution: Received photos of satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2025 Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. MI observed generator fuel hose containing only one hose clamp on either end of hose. Make repairs to the satisfaction of the Marine Inspector. 46CFR182.720(B) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2025
Resolved 25 February 2025
Resolution: Received photos of satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 February 2025 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI observed loose cover over dewatering pump. Make repairs to the satisfaction of the Marine Inspector. 46CFR177.960 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2025
Resolved 25 February 2025
Resolution: Received photos of satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 February 2025 Resolved
Internal combustion engine exhausts, boiler and galley uptakes, and similar sources of ignition must be kept clear of and suitably insulated from combustible material. MI observed lagging missing from turbo on PORT main diesel engine. Repairs affected during inspection. 46CFR177.405(b) 16c
Action required: 10 - Deficiency Rectified
Due 21 February 2025
Resolved 21 February 2025
Resolution: Lagging replaced during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2025 Resolved
Internal combustion engine exhausts, boiler and galley uptakes, and similar sources of ignition must be kept clear of and suitably insulated from combustible material. MI observed lagging missing from generator exhaust. Repairs affected during inspection. 46CFR177.405(b) 10c
Action required: 10 - Deficiency Rectified
Due 21 February 2025
Resolved 21 February 2025
Resolution: Lagging replaced during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 March 2024 Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Vessel's starboard engine has wet exhaust leak, leaking gas and water. Must repair for proper operation to the satisfaction of the Marine inspector. 46 CFR 182.430(b).
Action required: 705 - Other - as specified
Due 15 March 2024
Resolved 11 March 2024
Resolution: Received photos of exhaust weld and repairs to the satisfaction of the CG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 March 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. Vessel's crank case ventilation tube connection to air intake was broken. Must replace for proper operation to the satisfaction of the Marine inspector. 46 CFR 182.200(a).
Action required: 705 - Other - as specified
Due 15 March 2024
Resolved 11 March 2024
Resolution: Received photo verifying ventilation tube replaced with new to the satisfaction of the CG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 March 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. Vessels drip-less port shaft seal was excessively leaking. Must replace for proper operation to the satisfaction of the Marine inspector. 46 CFR 182.200(a).
Action required: 705 - Other - as specified
Due 15 March 2024
Resolved 11 March 2024
Resolution: Reviewed video of shaft seal replaced with new under proper operation to the satisfaction of the CG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2024 Resolved
Fuel tanks must be adequately supported and braced to prevent movement. The supports and braces must be insulated from contact with the tanks surfaces with a nonabrasive and nonabsorbent material. Vessels port and starboard fuel tank brackets found fractured. Must repair for proper operation to the satisfaction of the Marine inspector. 46 CFR 182.440(b)(3).
Action required: 705 - Other - as specified
Due 15 March 2024
Resolved 11 March 2024
Resolution: Received photos of brackets rewelded and repaired to the satisfaction of the CG.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 October 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. The MI observed the wiring for all three bilge high level alarms was not properly spliced and protected. 46 CFR 183.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2022
Resolved 22 November 2022
Resolution: Received photos of the bilge high level alarm connection within a junction box.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 October 2022 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The MMSI number was not entered and the GPS was not connected to the installed VHF radio. 46 CFR 184.502
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2022
Resolved 22 November 2022
Resolution: MMSI number and GPS was programmed into the radio.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 21 October 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that effect the safety of the vessel must not be made without the approval of the OCMI. In the steering gear room after bulk head near the top center line has an inset where a 1.5" crack has formed. 46 CFR 176.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2022
Resolved 22 November 2022
Resolution: crack was backgouged and welded.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 21 October 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that effect the safety of the vessel must not be made without the approval of the [name withheld] is a 3" crack on the welding seam for the Port Rudder Post. 46 CFR 176.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2022
Resolved 22 November 2022
Resolution: Crack was backgouged and welded.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 21 October 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2022
Resolved 22 November 2022
Resolution: Captain obtained FCC radio operator permit.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 21 October 2022 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Captain did not have a medical certificate. 46 CFR 10.301(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2022
Resolved 22 November 2022
Resolution: Mariner requested new copy of medical certificate from NMC.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 December 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. The MI observed the wiring for the starboard engine exhaust cooling water Flow/Temp meter had chaffed through to bare wire. Repair or replace wiring to meet intended purpose. 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2022
Resolved 10 January 2022
Resolution: Starboard engine exhaust cooling water Flow/Temp meter wires replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 December 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. The MI observed the wiring for all three bilge high level alarms was not properly spliced and protected. 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2022
Resolved 10 January 2022
Resolution: Received photos of wiring for all three bilge high level alarms properly spliced and protected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 December 2021 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The MI observed the cover to protect from the moving parts of the belts was missing from the generator. Install guard to protect from moving parts. 46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2022
Resolved 26 January 2022
Resolution: Guard installed on generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 December 2021 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The MI observed the cover to protect from moving parts was missing from starboard main engine. Install guard to protect from moving parts. 46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2022
Resolved 10 January 2022
Resolution: Protective guard installed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 29 December 2021 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. The MI observed the Certificate of Documentation was not onboard the vessel. 46 CFR 67.313(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2022
Resolved 3 January 2022
Resolution: Photo of COD onboard provided by vessel representative.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 December 2021 Resolved
Repairs or alterations to the hull, machinery, or equipment that effect the safety of the vessel must not be made without the approval of the OCMI. The aft most transverse frame on the starboard side separated from a weld, approx. 8”, and had a fracture in the frame approximately 8” to each side of the weld. The vertical frame and top girder on the port side in vicinity of the embarkation deck had broken welds. On the starboard side deck, where the aft most handrail stanchion meets the deck there are 02 separate 4” factures.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2022
Resolved 3 January 2022
Resolution: Satisfactory repairs of the fractures and cracked welds were conducted.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 29 December 2021 Resolved
Each hatch exposed to the weather must be watertight; except that, the following hatches may be weathertight. The MI observed the hatch opening for the ladder well to the engine space and the lazarette were missing gaskets. 46 CFR 171.124
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2022
Resolved 3 January 2022
Resolution: Photos of newly installed gaskets provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 December 2021 Resolved
Each generator must have a nameplate attached to it containing the information required by Article 445 of NFPA 70 (incorporated by reference; see 46 CFR 175.600), and for a generator derated in accordance with paragraph (b)(2) of this section, the derated capacity. The MI observed the generator was missing the data plate. 46 CFR 183.320(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2024
Resolved 5 April 2022
Resolution: A new data plate was requisitioned through the manufacture.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 December 2021 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The MMSI number was not entered and the GPS was not connected to the installed VHF radio. 46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2022
Resolved 10 January 2022
Resolution: MMSI number entered into VHF radio DSC data.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 December 2021 Resolved
Pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw air from within the protected space. The port main engine was disconnected from the pre-engineered fire-fighting system and did not shutdown during an operational test. 46 CFR 181.420(a)(3)
Action required: 10 - Deficiency Rectified
Resolved 29 December 2021
Resolution: The pre-engineered fixed fire-fighting system was reconnected to the port main engine. An operation test was conducted and the port main engine shut down during the test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 December 2021 Resolved
Each generator and motor must be designed for an ambient temperature of 50 °C (122 °F) except that a generator or motor designed for 40 °C (104 °F) may be used in 50 °C (122 °F) ambient locations provided the generator or motor is derated to 80 percent of the full load rating, and the rating or setting of the overcurrent devices is reduced accordingly. The generator onboard is rated for 40 °C and is in a location which exceeds 50 °C. Derate the generator to 80% of the full load rating, provide documentation from the manufacture that the insulation rating on the generator is rated for 50 °C, or replaced the generator with one that is rated is rated for 50°C.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2022
Resolved 5 April 2022
Resolution: The generator was derated to 80% of the full load rating to 30 amps.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 12 November 2020 Resolved
Repairs or alterations to the hull that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel must submit a repair proposal for the STBD side damage and hole in the forepeak side shell plating just forward of the collision bulkhead to the satisfaction of the marine inspector prior to starting repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 12 November 2020 Resolved
Repairs or alterations to the hull that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel must submit a repair proposal for the crack in the STBD forepeak side shell to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 12 November 2020 Resolved
Repairs or alterations to the hull that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel must submit a repair proposal for 02 previously repaired insets in the passenger void on the STBD side shell to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 12 November 2020 Resolved
Repairs or alterations to the hull that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel must submit a repair proposal for the STBD side passenger void cracked inset as identified in side shell plating to the satisfaction of the marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 January 2020 Resolved
Bow void bilge piping sheared at engine room bulkhead (fwd side). Prior to movement, correct to satisfaction of marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 January 2020
Resolution: Section of damaged piping removed and replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2020 Resolved
Port engine exhaust bellows found to have exhaust leak. Temp repair using high temp tape performed. Within 14 days, complete permanent repairs to satisfaction of marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2020
Resolved 14 January 2020
Resolution: Exhaust bellows replaced in kind and examined by USCG
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 January 2020 Resolved
Switchboard found to have open breaker slots. Within 14 days, correct to satisfaction of marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2020
Resolved 14 January 2020
Resolution: Open breaker slots covered with blanks