Records from 2016 to 2019. Most recent: inspection, 26 December 2019.
Documentation record
Registered dimensions (L × B × D)53.0 ft × 28.0 ft × 5.8 ft
Registered tonnagegross 78 / net 53
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKENNER MARINE & MARINERY · LAPLACE, LA, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it78 - Regulatory (Subpart C or D), Gross Ton
53 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 5
26 December 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6878963
26 December 2018
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6602880
19 November 2018
Examination of Repairs · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6583272
27 December 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6329446
30 December 2016
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6064101
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 December 2019
Resolved
Three (3) life jackets were not serviceable at the time of inspection. Vessel shall maintain serviceable life jackets at all times.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 December 2019
Resolved 27 December 2019
Resolution: Cleared to the satisfaction of the Marine Inspector
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 December 2019
Resolved
Port side generator was leaking excessive oil into the port engine room. Generator shall be maintained to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 January 2020
Resolved 21 January 2020
Resolution: Inspected repairs, all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 December 2019
Resolved
General electrical safety, Vsl had several loose or broken cables entering boxes/ connection boxes and not water tight. 183.115 to 183.10-20(old T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 January 2020
Resolved 27 December 2019
Resolution: Cleared to the satisfaction of the Marine Inspector
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 December 2019
Resolved
Permanent Repair was made to the fuel filter housing without prior approval that was not renewed to original. Permanent repairs or alterations shall be made with approval of OCMI.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 January 2020
Resolved 10 January 2020
Resolution: Repairs inspected, all sat
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 December 2019
Resolved
Name of vessel was not legible on both sides of the vessel that was observed. Name of vessel shall be legible
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 January 2020
Resolved 27 December 2019
Resolution: Cleared to the satifaction of the Marine Inspector.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 26 December 2019
Resolved
Pre use inspections are not completed or logged. Complete and log pre use inspections per API RP2D 4.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 January 2020
Resolved 27 December 2019
Resolution: Cleared to the satisfaction of the Marine Inspector.
Lifesaving › Lifebuoys › Serviceable
Issued 30 December 2016
Resolved
One ring life buoy found water logged and unservicable. Replace ringbuoy.
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 3 January 2017
Resolution: New ring buoy provided onboard.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 December 2016
Resolved
All electrical systems on board shall be designed and installed to protect persons from electrical shock. Place spliced wiring in head in junction box.
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 3 January 2017
Resolution: Proper repairs made to electrical wiring.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 December 2016
Resolved
All rotating machinery shall have sufficient guards to protect personnell from injury. Add guard to STBD PTO.
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 3 January 2017
Resolution: Suitable guards added to machinery installation.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 30 December 2016
Resolved
Provide certification for deck crane. Provide crane record book.
Action required: 705 - Other - as specified
Due 19 January 2017
Resolved 6 January 2017
Resolution: Crane inspected & maintained IAW API 2D, 60-month load test conducted per 46 CFR 107.26, and crane record book assembled.