MAURY USCG vessel records
← All vessels

HYDRUS

HYDRUS is a 2017 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2017, most recently in February 2026, along with 31 deficiencies — 2 with no resolution recorded — and 2 operational controls.

Records from 2017 to 2026. Most recent: operational control imposed, 19 February 2026.

Built
2017
Last inspected
18 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDJ3145
1375738
Flag
UNITED STATES
Maury page id
psix-1375738

Inspections, by type

Years with a record 10 calendar years (2017–2026)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)133.9 ft × 37.1 ft × 10.5 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)133.9 ft × 37.1 ft × 10.5 ft
ITC tonnagegross 565 / net 194
BuilderVIGOR KVICHAK LLC · Seattle, WA, UNITED STATES · built 2017
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it565 - Convention (Subpart B), Gross Ton
94 - Regulatory (Subpart C or D), Gross Ton
194 - Convention (Subpart B), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 21

18 February 2026 Administrative Inspection · Vessel Attendance
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8312491
22 May 2025 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8111539
30 October 2024 Administrative Inspection · Hull Examination · Drydock Exam · Deficiency Check · Internal Structural Exam · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8027023
3 October 2024 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8013729
20 June 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7990160
4 March 2024 Internal Structural Exam · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7873664
6 March 2023 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7645067
17 October 2022 Drydock Exam · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7579215
25 May 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7459348
22 March 2022 COI Inspection · Internal Structural Exam · DAPI Audit · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7408353
27 April 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7183159
29 December 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7117584
4 November 2020 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7089632
31 May 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6964335
29 April 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6946898
20 December 2019 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6877287
24 September 2019 Administrative Inspection · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6820195
23 April 2019 MTSA Verification · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6668418
17 October 2018 In-Service Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6567451
18 April 2018 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6393722
3 April 2017 Plan Review (Other than "T") · Deficiency Check · Initial Certification · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6113567

Deficiency record · 31

02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 3 March 2026 No resolution recorded
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space, including fuel tanks, and may require the vessel to be dry docked or taken out of service to assess the extent of the damage, and to effect permanent repairs. MI identified a second fracture in starboard transom plate in vicinity of the waterline. Provide details of repair plan and effect repairs to the satisfaction of the attending Marine Inspector, prior to the carriage of passengers. 46 CFR 115.600(d)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 February 2026 No resolution recorded
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space, including fuel tanks, and may require the vessel to be dry docked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Vessel reported 3" horizontal transom plate fracture below the waterline and affixed a temporary patch. Provide details of repair plan and effect repairs to the satisfaction of the attending Marine Inspector, prior to the carriage of passengers. 46 CFR 115.600(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 May 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Gaskets on aft engine room doors found to be wasted; replace to MI satisfaction. 46 CFR 115.830 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 13 June 2025
Resolution: Operator replaced gaskets on both engine room doors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2025 Resolved
Electrical equipment used in the following locations must be dripproof: A machinery space. Missing cable run cover found on port engine room prop feed panel. 46 CFR 120.210 (a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 13 June 2025
Resolution: Operator replaced missing cap for electrical box.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 May 2025 Resolved
Each survival craft must be: Secured to the vessel by a painter with a float-free link permanently attached to the vessel. Stbd aft IBA float-free arrangement found installed improperly. Operator corrected on the spot. 46 CFR 117.130 (a)(1)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 22 May 2025
Resolution: Corrected on spot.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 May 2025 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by table 1 to § 118.500(b) and other provisions of this section. Fire extinguishers found in incorrect locations per table 1 and vessel's fire control plan. Operator corrected on spot. 46 CFR 118.500 (a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 22 May 2025
Resolution: Corrected on spot.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 4 March 2024 Resolved
Vessel was found with no master key control system, control access, use of master keys, and handling protocols. Develop and implement required master key requirements to the satisfaction of the Marine Inspector. 46 USC 3106 CVC Policy Letter 23-06
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2024
Resolved 19 April 2024
Resolution: Vessel developed plans and were found satisfactory.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 March 2024 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel was unable to produced the MMSI that needs to be programed into their radio system for compliance with 80.905(a) Vessel must program their radio with the proper MMSI number to the satisfaction of the Marine Inspector. 46 CFR 121.502
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2024
Resolved 8 March 2024
Resolution: Vessel submitted photographs of displayed MMSI as required. Photos placed in documents.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 March 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel did not have the required contents in their med kit as required in ISO 18813.2006(E). Vessel must procure the correct contents to the satisfaction of the Marine Inspector. 46 CFR 121.710
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2024
Resolved 19 April 2024
Resolution: Vessel purchased a new first aid kit. Def is cleared.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 March 2024 Resolved
Rugs and carpets are not permitted in machinery spaces, high risk service spaces, or areas where the spillage or leakage of flammable or combustible liquids is possible including areas immediately adjacent to bar service areas. Vessel has carpet extending to the vessel’s bar area that contains hard liquors. Vessel must remove the carpet to the satisfaction of the Marine Inspector. 46 CFR 116.423(4)(ii) MTN 01-13
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2024
Resolved 30 August 2024
Resolution: Rescinded def after reconsideration request has been approved.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 4 March 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks; Vessel was found with a fracture in a weld aft of the stbd side spring line cleat. Vessel must submit repair proposal of the crack to the satisfaction of the Marine Inspector. 46 CFR 115.802(a)(1)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2024
Resolved 30 October 2024
Resolution: Area inspected and no fracture found.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel was missing two life jackets in the operation station. Vessel received two new lifejackets for the space and installed placards for where they are stored. 46 CFR 117.71(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 March 2024
Resolved 4 March 2024
Resolution: Vessel received two new lifejackets for the space and installed placards for where they are stored.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 March 2024 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel was missing a portable light at the operation station and both machinery space light batteries needed to be replaced. Vessel POC installed a new portable light for the operation station and replaced batteries in the other lights. 46 CFR 120.430
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 March 2024
Resolved 4 March 2024
Resolution: Vessel POC installed a new portable light for the operation station and replaced batteries in the other lights.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 May 2022 Resolved
The construction of a vessel must allow for a seaworthy hull. Vessel struck pier, leading to a 1/4" hole on the starboard bow of the hull. 46 CFR 116.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2022
Resolution: Operator installed 3 inserts on the starboard rub rail and starboard bow of the vessel. Photos added to documents.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 22 March 2022 Resolved
Penetrations in A-Class fire control boundaries for pipes must be constructed to prevent the passage of flame and smoke for one hour. A-0 boundary behind fire station #1 has a penetration that does not meet A-Class fire control. Passage of fire station water pipe must be made to meet standard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 28 March 2022
Resolution: Vessel properly sealed around water supply line to firestation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 March 2022 Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as is is reasonable and practicable. Door leading to pantry storage is required to be self closing. MI found that door did not close due to a frozen latch.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 March 2022
Resolution: Door latch cleaned and lubricated. Tested successfully.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 March 2022 Resolved
All cable and wire be installed with metal supports spaced not more than 24 inches apart and in such a manner as to avoid chafing and other damage. Hug Engineering monitor in starboard engine room has an incorrectly installed cable run that is not supported and is not properly installed into junction box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 10 May 2022
Resolution: Sent photos of cable supports intalled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. During the inspection of the crawl space behind bridge console, MI found dead end wiring, disconnected grounding cables, an uninstalled junction box cover, and several magazines.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 28 March 2022
Resolution: Vessel properly supported electrical cables and eliminated dead end wires.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 March 2022 Resolved
Small batteries. Each small battery installation must be located in a well ventilated space. A small battery installation must not be in a closet, storeroom, or similar space. Marine Inspector found battery storage under bridge deck does not have ventilation. Submit plan for modification of space that meets ABS Rules for battery installations and venting for small battery installations on a vessel <90m as per original plan requirements.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 1 July 2022
Resolution: Received repair plan for ventillation installation.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 March 2022 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to have the vessel ready for inspection of electrical equipment and systems including lighting. MI discovered bulbs missing in lighting fixture above port side gearbox.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 1 July 2022
Resolution: Crew replaced bulbs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2022 Resolved
A vessel must either carry a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit missing aspirin sea sickness tablets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 10 May 2022
Resolution: Replaced expired items.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 22 March 2022 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Emergency lights on main deck and forward end of second deck are not marked as emergency lighting.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 10 May 2022
Resolution: Vessel installed "E" signs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2020 Resolved
Each portable fire extinguisher on a vessel must contain the minimum required rating as indicated in 46 CFR 118.500 (a) table. Both machinery fire extinguishers are size 10 B:C and are required to be 40 B:C. 46 CFR 118.500 (a)(b).
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2020
Resolved 1 June 2020
Resolution: 2 40-B:C extinguishers installed over each engineroom entrance.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 23 April 2019 Resolved
A fire control plan must show structural fire protection boundaries. Vessel fire control plan depicts self-closing fire doors leading to port and starboard engine room hatch spaces, however vessel fire doors into both spaces are not self closing. Vessel must make fire doors self closing to match the approved fire control plan, or amend the fire control plan to accurately show what is in use on the vessel.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 1 May 2019
Resolution: Vessel operator submitted photos of self closing door mechanism re-installed on both machinery space doors to match the self closing requirement on fire control plan.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 April 2019 Resolved
A door in a bulkhead required to be A-0 Class must be of solid or hollow steel or equivalent material construction, and capable of meeting the requirements of an A-0 Class bulkhead. A-60 self closing fire door for second deck bathroom aft of the operating station had key/locking device removed leaving an open penetration through the A Class fire boundary. Vessel must seal penetration with equivalent material to meet the required A Class fire boundary.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2019
Resolved 30 April 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 April 2019 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape and must automatically actuate upon failure of the main lighting system. Two emergency lighting fixtures for exit signs in port forward and stbd aft of main deck did not automatically actuate upon main lighting system failure. Vessel must repair extinguished emergency lights.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 30 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 23 April 2019 Resolved
At each inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. CO2 tank in use for snack bar not secured. Vessel must ensure CO2 tank to be secured in place to handle any adverse sea state or movement.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 30 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 23 April 2019 Resolved
A fire control plan must show structural fire protection boundaries. Vessel fire control plan depicts self-closing fire door leading to starboard side utility room aft of snack bar, however vessel fire door was not self closing. Vessel must make fire door self closing to match the approved fire control plan, or amend the fire control plan to accurately show what is in use on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 23 April 2019
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 13 April 2017 Resolved
Provide A-0 stbd steering hatch or insulate existing hatch to A-0 as indicated on approved plans. Prove rubber between hull and superstructure in stbd steering meets A-0 or submit plan to OCMI to bring up to standard. As an alternative, provide MSC approved plans that reflect as built specification of non-insulated aluminum hatches and rubber boot arrangement.
Action required: 705 - Other - as specified
Due 13 May 2017
Resolved 12 May 2017
Resolution: Suitable structural fire protection provided.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 13 April 2017 Resolved
Provide revised MSC approved FMEA/DVTP/PSTP procedures indicating exact breakers/pin #'s and locations for testing, revise PSTP procedures to eliminate DVTP portions, prove revised procedures if OCMI determines changes warrant new testing.
Action required: 705 - Other - as specified
Due 13 May 2017
Resolved 12 May 2017
Resolution: MSC approved FMEA/DVTP/PSTP plans, new testing not required.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 3 April 2017 Resolved
Provide MSC approved plans for sewage system (revise plan to eliminate discharge reference), lube oil, potable water, HVAC, main engine cooling. Local plan review conducted to permit operations while MSC reviews plans.
Action required: 705 - Other - as specified
Due 13 May 2017
Resolved 1 June 2017
Resolution: Plans approved.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.