Records from 2017 to 2026. Most recent: casualty investigation, 30 July 2026.
Inspection history · 25
8 May 2026
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8369293
12 June 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8157466
25 September 2024
Internal Structural Exam · Deficiency Check · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8009423
26 June 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7941673
31 March 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7892683
30 March 2024
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7887495
19 March 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909345
18 March 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7881430
10 July 2023
MTSA Verification · Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7738866
21 December 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7611844
27 September 2022
Internal Structural Exam · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7567546
22 June 2022
COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7470120
3 August 2021
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7270989
9 October 2020
Administrative Inspection · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7074687
17 September 2020
Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7060321
30 July 2020
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7019040
23 August 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6792738
17 June 2019
Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6717015
16 June 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7107659
18 March 2019
Administrative Inspection · In-Service Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6646762
2 November 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6573655
2 October 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6553371
18 July 2018
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6469577
9 August 2017
Deficiency Check · Plan Review (Other than "T") · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6235707
5 May 2017
Construction Oversight · COI Inspection · Deadweight Survey · Plan Review (Other than "T") · Deficiency Check · Administrative Inspection · Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6139550
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 June 2025
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Port side shaft cooling line found leaking at the elbow. Corrected to satisfaction of MI during inspection. 46 CFR 119.100
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 June 2025
Resolution: Corrected to satisfaction of MI during inspection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 June 2025
Resolved
All electrical equipment and circuits must be clearly marked and identified. Port and starboard side main electrical distribution panels had incorrect labeling on #1 breakers, which were listed as 25 amps instead of 10 amps. Corrected to satisfaction of MI during inspection. 46 CFR 120.220(d)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 12 June 2025
Resolution: Corrected to satisfaction of MI during inspection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 June 2025
Resolved
Minimize accidental personnel contact with energized parts. Dead end wires were found at the starboard side damper close signal cable. Corrected to satisfaction of MI during inspection. 46 CFR 120.200(c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 June 2025
Resolution: Corrected to satisfaction of MI during inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 September 2024
Resolved
Internal combustion engine exhausts, boiler and galley uptakes, and similar sources of ignition must be kept clear of and suitably insulated from combustible material. Port/STBD insulation in the engine room found to be torn, make repairs to the satisfaction of MI prior to credit DD.
46 CFR 116.405(c)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 5 December 2024
Resolution: Operator repaired identified areas of torn insulation to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 September 2024
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the following normally unmanned spaces. Bilge high level alarm in the laz found to not be mounted, repair to the satisfaction of MI prior to credit drydock.
46 CFR 119.530(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 5 December 2024
Resolution: Operator mounted bilge high level alarm to the satisfaction of the MI.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 26 June 2024
Resolved
On a vessel of more than 65 feet in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members [name withheld] system on the forward main deck had multiple inoperable speakers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2024
Resolved 29 July 2024
Resolution: Observed functioning PA System.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 June 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the
vessel ready for inspections of the hull structure and
its appurtenances, including the following: Inspection and operation of all weathertight closures above the weather deck. There were 02 holes in the forward port and starboard main deck doors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2024
Resolved 29 July 2024
Resolution: Observed dogs in main deck doors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 June 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. The vessel was missing 05 adult life jackets onboard. Vessel representative brought 05 new life jackets during the inspection.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 26 June 2024
Resolution: Vessel respresentative brought 05 life jackets during the inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 March 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Operator reported loss of propulsion and steering. Provide root cause and corrective actions.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 April 2024
Resolution: Duty lead intended a sea trial to witness machinery and steering function.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 March 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. When vessel is operated outside the programmed "crash stop protocol" operators risk potential stall event. Company to identify appropriate mitigating factors and present to the Marine Inspectors.
46CFR119.200(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 14 May 2024
Resolution: Vessel submitted copies of the incorporated crssh stops. Founds satsifactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2024
Resolved
All microprocessor or computer based systems must meet the requirements of part 62 in sub chapter F of this chapter. Vessel operators were unable to verify which propulsion control screen was the primary screen. Label primary and secondary screens to the satisfaction of the Marine Inspector.
46CFR121.620(d)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 14 May 2024
Resolution: Verified corrected labeling, all satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Operator reported loss of the starboard main engine. Provide root cause and corrective actions.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2024
Resolution: MI conducted sea trial and noted and electrical functioning properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 July 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Inspection of all machinery essential to the routine operation of the vessel including generators and cooling systems. The port generator is inoperable. Make repairs to the satisfaction of the attending MI.
46 CFR 115.804(c)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2023
Resolution: Attending MI verified repairs and operations of the port generator.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 July 2023
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Vessel was unable to conduct man overboard drills.
46 CFR 115.808(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2023
Resolved 11 July 2023
Resolution: Conducted man overboard drills.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 21 December 2022
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space, including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Crack on hull in port, aft lazarette. Repair crack to the satisfaction of the attending marine inspector.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 December 2022
Resolved 28 December 2022
Resolution: Verified repair at BSY. Hull insert welded in and air lance and vac box NDT. All sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 27 August 2019
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Master was unable to provide a copy of a valid medical certificate. Provide proof of valid certificate to marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 22 October 2019
Resolution: Received a picture of the valid medical certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 August 2019
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments. STBD lazarette bilge pump was inoperable. Engineers replaced the bilge pump and demonstrated proper operation directly after the inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 August 2019
Resolved 27 August 2019
Resolution: Observed proper operation of the stbd bilge pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 August 2019
Resolved
The stowage locations of the personal flotation devices carried in addition to life jackets must be separate from the life jackets, and such as not to be easily confused with that of the life jackets. Work vests were stored with adult and children life jackets. Store work vests separately and label appropriately.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 27 August 2019
Resolved 27 August 2019
Resolution: Corrected on the spot. Stored work vests separately.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 9 August 2017
Resolved
SUMBIT TWO IDENTIFIED MODIFICATIONS TO THE PERIODIC SAFETY TEST PROCEDURES TO MSC.
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 6 November 2017
Resolution: PSTP not required
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 August 2017
Resolved
PROVIDE ONBOARD CERTIFICATE OF DOCUMENTATION.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2017
Resolution: COD issued and on-board 8/25
Engineering › Fuel Oil Service System › Filter
Issued 9 August 2017
Resolved
PROVIDE METALLIC FUEL OIL FILTERS (OR CG/ASTM1201 APPROVED)FOR PORT/STBD GENERATORS
Deficiency extended to allow builder rep approval of current installation through MSC.
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 2 October 2018
Resolution: Received documentation and photos for proper fuel filter install.
Electrical › Electric Supply System (service) › Cable
Issued 9 August 2017
Resolved
PROVIDE METALLIC WIRE TIES FOR ELECTRICAL RUNS BEHIND EXHAUST STACK AND GENERATORS.
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 7 December 2017
Resolution: Vessel replaced plastic ties with stainless.
Construction/Loadline › Hull › Bottom Plating
Issued 9 August 2017
Resolved
CLEAN ALUMINUM HYDROXIDE RESIUDES FROM STBD LAZARETTE BILGES TO DETERMINE PITTING DEPTH IN BOTTOM PLATING.
Deficiency extended to coincide with next DD date.
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 22 March 2019
Resolution: Verified condition of starboard laz free from residue.
Construction/Loadline › Structures › Door
Issued 9 August 2017
Resolved
ADJUST ALL FIRE SCREEN DOOR LATCHES TO ENSURE PROPER CLOSURE/LATCHING UNDER ALL NORMAL OPERATING CONDITIONS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2017
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 9 August 2017
Resolved
PROVIDE FINAL APPROVAL DOCUMENTATION FOR DVTP/PSTP'S FROM THE MARINE SAFETY CENTER.
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 8 November 2017
Resolution: Vessel rep provided MSC approval letters for DVTP.
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 May 2017
Resolved
Vessel has not completed drills, docs/certs inspection, DAPI audit, placard inspection, operations review, generator fuel filter, anchor, and IBA inspections, per activity narrative. Vessel shall complete New to Zone inspection, addressing these issues with OCMI, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2017
Resolution: Vessel completed New to Zone exam; issued 06 deficiences including 01 detailed in this 835.