Records from 2015 to 2026. Most recent: inspection, 5 June 2026.
Documentation record
Registered dimensions (L × B × D)345.1 ft × 62.0 ft × 24.5 ft
Registered tonnagegross 4,317 / net 2,495
ITC dimensions (L × B × D)345.1 ft × 62.0 ft × 24.5 ft
ITC tonnagegross 4,317 / net 2,495
BuilderCONRAD SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2017
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBALTIMORE, MD
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 October 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4317 - Convention (Subpart B), Gross Ton
2495 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
5 June 2026
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8369233
27 February 2025
MTSA Verification · Periodic Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8113208
18 April 2024
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7896988
12 February 2024
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7864335
28 October 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7815629
28 October 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7816265
24 May 2023
Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7694542
2 May 2022
Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7442292
12 January 2022
Internal Structural Exam · MARPOL Annex VI Survey · COI Inspection · Administrative Inspection · Drydock Exam · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7379003
17 May 2021
Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7199144
6 February 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7136821
29 August 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7046580
19 May 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6956078
6 February 2020
Administrative Inspection · In-Service Inspection · Internal Structural Exam · Periodic Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6897322
24 July 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6760927
17 May 2019
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6686642
10 June 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6439816
10 April 2018
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6388511
10 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6121071
7 February 2017
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6095337
7 December 2015
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5908073
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 5 June 2026
Resolved
Each operation described in paragraphs (d), (e) and (f) of this section shall be fully recorded without delay in the Oil Record Book so that all the entries in the book appropriate to that operation are completed. Oil Record Books Part I and II contained incorrect entries (wrong codes), missing entries (eg weekly soundings of residual oil tank), and white out for corrections. Company to add ORB training to monthly training schedule. 33 CFR 151.25(h)
Action required: 10 - Deficiency Rectified
Resolved 5 June 2026
Resolution: Company to hold ORB training.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 June 2026
Resolved
The cargo handling equipment shall be maintained by the tank vessel's personnel in accordance with the regulations in this subchapter. Cargo pump lagging found oil soaked. 46 CFR 35.35-70
Action required: 10 - Deficiency Rectified
Resolved 5 June 2026
Resolution: Oil soaked lagging removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2024
Resolved
Each AC switchboard must have a frequency meter with a selector switch to connect the meter to each generator; Common frequency meter at switchboard did not connect to the meters on #1/#2 generators in aft machinery space, to repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 April 2024
Resolution: New meter installed, tested, and reading 60 hz on both generators.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 October 2023
Resolved
MI was informed that the barge had run aground in the vicinity of Saugerties, NY. The barge must complete a satisfactory underwater survey prior to leaving Saugerties,NY.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 October 2023
Resolved 29 October 2023
Resolution: The subject barge was attended by a ABS surveyor and an approved dive company while the vessel was anchored in Saugerties NY. In the presence of the attending surveyor, a live video feed of the under water hull examination by the dive team show no damage.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 24 May 2023
Resolved
There shall be at least two means of escape from all general areas accessible to the passengers, if carried, or where the crew may be quartered or normally employed. Crew accommodation escape hatch was not watertight, make repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2023
Resolved 31 May 2023
Resolution: Recieved pictures verifying proper repairs of the deficency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 May 2022
Resolved
Vessel Rep reported that FWD Thermal Fluid heater was leaking fluid from coils inside of heater. Heater is not to be used until repairs are conducted to the satisfaction of ABS & U.S.C.G.
Action required: 705 - Other - as specified
Due 2 May 2022
Resolved 13 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2021
Resolved
Starboard ring lifebuoy had cracked bung making it non-watertight and SOLAS retro tape was faded/torn apart. This was corrected prior to the end of the inspection.
46 CFR §199.70(a)
Action required: 10 - Deficiency Rectified
Due 17 May 2021
Resolved 17 May 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 May 2021
Resolved
Starboard cargo pump engine has exhaust leak that created a pool of oil on deck. Barge must address the source of the leak and clean the area.
46 CFR §32.35-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 19 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 29 August 2020
Resolved
Replace anchor in kind to the satisfaction of class. Provide report to USCG Sector New Orleans.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 August 2020
Resolution: Received satisfactory repair report from ABS.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 17 May 2019
Resolved
Each cargo tank of tank barge must have one of the following liquid overfill protection arrangement. Hihg-level and overfill alarm. Alarms on cargo tanks 1p, 4p, and 3 stb are not able to be tested.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2019
Resolution: The Operator of the barge heated all cargo tanks. At this time, the level alarms on 1 Port, 4 Port and 3
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 May 2019
Resolved
Each ungrounded system must be provided with a suitably sensitive ground detection system. Found a ground in the 208/120v panel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2019
Resolution: At this time, the electrician dried the navigation light fixure. Dessicant bags were installed within the fixture.