Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it63023 - Dead Weight, Metric Ton 75085 - Displacement, Metric Ton 36416 - Convention (Subpart B), Gross Ton 21225 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
14 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 14
15 October 2024PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8015419
21 June 2022Ballast Water Examination · PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7475979
17 March 2022Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7413458
20 December 2020Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7114440
18 November 2020PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7091418
4 July 2019Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6735553
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Chief Engineer informed PSCO audible and visual indicators n engine space for fire and machinery control alarms were inoperable. Vessel is prohibited from operating with an unmanned machinery space until deficiency is rectified.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2020
Resolved 20 December 2020
Resolution: PSC NOLA recieved a class report from NKK satisfying the requirements.
1430-Auxiliary Engines.A second source of energy shall be provided for an additional three starts within 30 minutes unless manual starting can be demonstrated. Emergency Generator failed to start using the spring start. 74 SOLAS (14) II-1/44.1
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2017
Resolved 7 March 2017
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 2 March 2017Resolved
0725 - Fixed fire extinguishing systems. Shall be readily accessible. PSCO observed that the fixed CO2 system for the forward paint locker had limited accessibility due to padlock and key storage location being on the bridge. 74SOLAS(14) III/8.4.3
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 7 March 2017
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 2 March 2017Resolved
0915- Signs and indications. Illustrations and instructions shall be posted at muster stations to provide instructions for donning lifejackets. 74 SOLAS (14) III/8.4.3 10c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 2 March 2017
Resolution: The instructiosn for donning life jackets was posted at the muster station.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 7 April 2016Resolved
1599- Other (Navigation) The condition of the ship and its equipment shall be maintained to conform with the provisions pf te [resent reglations to ensure that the ship in all respects remain fit to proceed without danger to the ship or persons on board. The Voyage Data Recorder displays an error code for smoke detection. 74SOLAS(14)I/11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 7 April 2016
Resolution: Electrician discovered disconnected cable and was able to reconnect.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.