MAURY USCG vessel records
← All vessels

REGULA

REGULA is a 2008 freight ship. The Coast Guard has recorded 49 inspections since 2016, most recently in June 2026, along with 9 deficiencies and 6 operational controls.

Records from 2016 to 2026. Most recent: inspection, 8 June 2026.

Built
2008
Last inspected
8 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 June 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9430064
1376651
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-1376651

Documentation record

Tonnage as PSIX records it7219 - Convention (Subpart B), Gross Ton
8164 - Dead Weight, Metric Ton
12421 - Displacement, Metric Ton
3068 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 49

8 June 2026 PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8392608
20 March 2026 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8329366
4 March 2026 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8319656
18 February 2026 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8312028
6 February 2026 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8307131
6 January 2026 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8291004
23 December 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8286739
9 December 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8279739
6 December 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8278148
11 November 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8266944
28 October 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8259994
14 October 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8251710
1 October 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8244727
16 September 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8235239
2 September 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8225324
28 August 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8219993
19 August 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8213122
6 August 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8203674
31 July 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8199119
22 July 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8191543
16 July 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8187248
8 July 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8178883
23 June 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8166913
5 June 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8152525
18 December 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8047764
2 December 2024 PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8041588
2 June 2024 PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7924589
2 December 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7831040
1 January 2023 PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7615088
11 September 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7556156
20 June 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7481985
5 May 2022 PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7444360
5 November 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7344539
30 October 2021 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7342341
25 October 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7339615
23 December 2020 PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7115778
10 December 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6871732
18 June 2019 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6716524
4 June 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6700701
4 June 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6702956
3 June 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6701755
28 January 2019 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6616365
1 June 2018 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6431153
4 May 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6405664
30 March 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6381739
3 April 2017 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6116683
24 March 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6107954
30 December 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6064204
10 March 2016 ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5830513

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 November 2021 Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. 02 emergency escape doors in engine room were not self-closing properly. 74 SOLAS (04) II-2 9.4.2.1
Action required: 10 - Deficiency Rectified
Resolved 5 November 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2021 Resolved
MEANS SHALL BE PROVIDED TO ENSURE THAT THE MACHINERY CAN BE BROUGHT TO OPERATION FROM THE DEAD SHIP CONDITION WITHOUT EXTERNAL AID. VESSEL IDENTIFIED THE MAIN CONTROL OF THE FUEL LIMITER IS INOPERATIONAL THEREBY REQUIRING MANUAL LOCAL OPERATION. 74 SOLAS (04) CH. II-1/ REG 26.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2021
Resolved 7 November 2021
Resolution: 08Nov21: Vessel provided documentation that governor was fixed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 June 2019 Resolved
Where necessary non-conducting mats or gratings shall be provided at the front and rear of the switchboard. non-conducting matting was absent from multiple switchboards in the engine room, fire control station, and CO2 room. 74SOLAS(04)II-1/45.2
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 18 June 2019
Resolution: crew installed non conducting matting in appropriate areas
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pump Power Supply
Issued 4 May 2018 Resolved
0725- Fire Protection Systems and Fire-Fighting Systems shall be maintained ready for use. PSCO observed engine room water mist control panel in the off position, rendering the automatic operation of the fixed local application fire extinguishing system as required by II-2/10.5.6 inoperable. Chief engineer stated panel was turned off during testing on 27APR18. Additionally, Bureau Veritas identified deficiency for water mist system being in the off position on 03FEB18. - 74SOLAS(14) II-2/14.1.1 - 30AC
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Due 4 May 2018
Resolved 5 May 2018
Resolution: Received proper documentation from certificate issuing authority that the water mist system was tested and placed in automatic operation.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 4 May 2018 Resolved
0750 - Fire Prevention - The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed multiple areas of accumulated and standing oil on and around the main engine. Crew previously placed cardboard sheets to deflect spraying oil into the bilge. Cardboard was oil soaked at time of inspection. Chief engineer stated one oil leak was in vicinity of crankshaft seal. 74SOLAS(04) II-2/4.1.1 - 30AC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 4 May 2018
Resolved 5 May 2018
Resolution: Received proper documentation from certificate issuing authority that area was cleaned of oil and recommendation was made to renew main engine crankshaft seal.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 11 March 2016 Resolved
0600-An embarkation ladder complying with the LSA code shall be provided at each embarkation station. Embarkation ladders for the liferafts, on both port and starboard, are severely wasted. 74SOLAS(14)Ch.III/Reg. 11.7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2016
Resolved 12 March 2016
Resolution: Received and accepted the Class report for corrected embarkation ladders. Deficiency cleared.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 11 March 2016 Resolved
0710-Waste receptacles shall be constructed of non combustible materials. The waste receptacles in the galley are constructed of plastic. 74SOLAS(14)CH.II-2/4.4.2
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 11 March 2016
Resolution: Corrected on the spot.
Fire Fighting › International Shore Connection › Gasket
Issued 11 March 2016 Resolved
0720-Ships of 500 gross tonnage and upwards shall be provided with at least one international shore connection complying with the Fire Safety Systems Code. International shore connection in the emergency diesel generator room is missing the gasket. 74SOLAS(14)Ch.II-2/10.2.1.7.1
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 11 March 2016
Resolution: Corrected on the spot.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Service
Issued 11 March 2016 Resolved
0720-Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. The semi portable fire extinguisher outside the auxiliary generator room is missing a seal which would indicate its operational readiness. 74SOLAS(14) Ch. II-2/Reg. 14.1.1
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 11 March 2016
Resolution: Corretced on the spot.

Ownership record