11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 September 2024
Resolved
A small passenger vessel of not more than 65 feet must have one ring life buoy. The life ring buoy must be fitted with a floating water light approved in accordance with 46 CFR 160.010 and properly secured around the body of the life ring buoy in accordance with 46 CFR 180.70(c). The water light was stowed in the upright position and the battery was corroded rendering the light inoperable. Provide and properly secure a new floating water light on the Life Ring Buoy to the satisfaction of a Coast Guard Marine Inspector no later than September 20, 2024
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 12 September 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 April 2024
Resolved
A Certificate of Inspection may be suspended and withdrawn or revoked by the cognizant OCMI at any time for noncompliance with the requirements of this subchapter.This vessel has four (04) outstanding deficiencies that were issued to the owner on May 17, 2023. No action has been taken to correct these deficiencies. The COI has been deactivated and the vessel is not allowed to carry passengers until alkl deficiencies have been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 May 2023
Resolved
Vessels pre-engineered (Fireboy) fire extinguishing system protecting the machinery space does not shut down the generator and does not meet the minimum standard of automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space in accordance with 46 CFR 181.420(a)(3). The vessel is restricted from carrying passengers until corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 September 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Provide Type 1 life jackets for total persons on board as allowed by your COI. Vessel is restricted to 48 total persons on board. 46CFR180.71(a)
Action required: 705 - Other - as specified
Resolved 12 June 2023
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 May 2023
Resolved
Provide proof of pre-employment drug testing and enrollment in the Company's random drug testing pool for all employees in a sensitive safety position in accordance with 46 CFR 16.210. Members (Clint Adkins and Chris Jacobs) are not authorized to fill any safety sensitive position on the vessel until the necessary proof of pre-employment and enrollment in the random program are received and reviewed by this office
Action required: 705 - Other - as specified
Resolved 6 September 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 May 2023
Resolved
Vessels first aid kit is expired and does not meet the minimum requirements per 46CFR184.710 and 46CFR 160.041. Vessel has 30 days to correct to the satisfaction of the CG Marine Inspector. The vessel will be restricted from carrying passengers after June 17, 2023 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 5 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 May 2023
Resolved
Vessels Fire bucket lanyard and did not meet the minimum requirements as described in 46CFR181.610. Vessel must have at least three 9.5 liter (2 1 /2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. 46 CFR 181.610. Provide new attached lanyards. The vessel will be restricted from carrying passengers after June 17, 2023 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 12 June 2023
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 May 2023
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The markings required be made by the use of any means and materials which result in durable markings, must be made in clearly legible letters of the Latin alphabet or Arabic or Roman numerals not less than four inches in height. 46CFR67.123 Ensure vessel name is marked. The vessel will be restricted from carrying passengers after June 17, 2023 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 12 June 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2023
Resolved
Vessels machinery space ventilation does not have a closure device and does not meet the minimum standard of provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent as described in 46CFR182.460. The vessel will be restricted from carrying passengers after June 17, 2023 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 6 September 2024
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 May 2023
Resolved
EAP training program: An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. 46CFR16.401. No evidence of training program or 60 minutes of supervisory training. The vessel will be restricted from carrying passengers after June 17, 2023 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 6 September 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 May 2023
Resolved
A flammable vapor detection system must be operational for 30 seconds prior to engine startup and continue sensing the entire time the engine is running. 46CFR182.480( c ). Vessel was observed with engine running underway and the vapor detection system off. Was corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 16 May 2023
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 26 August 2021
Resolved
COD is expired.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2021
Resolution: Vessels COD is valid until September 30, 2021.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 August 2021
Resolved
Collision bulkhead penetrations are not sealed properly.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 20 September 2021
Resolution: The master provided objective evidence in the form of photographs and an invoice to prove corrective action has been taken to correct this deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 August 2021
Resolved
Forward lifebuoy throw line does not meet the required length.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 20 September 2021
Resolution: The master provided objective evidence in the form of photographs and an invoice to prove corrective action has been taken to correct this deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 August 2021
Resolved
The aft main deck lifebuoy outer covering is damaged.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 20 September 2021
Resolution: The master provided objective evidence in the form of photographs and an invoice to prove corrective action has been taken to correct this deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2021
Resolved
The high water level indicator midships is wired in with a extension cord.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 20 September 2021
Resolution: The master provided objective evidence in the form of photographs and an invoice to prove corrective action has been taken to correct this deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 August 2020
Resolved
46CFR182.500- Remount automatic bilge switch for bilge pump for aft compartment. Def due 12SEP2020 and extended to 12OCT2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 12 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 August 2020
Resolved
46CFR182.460- Repair vent closures
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2020
Resolved 12 October 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2020
Resolved
46CFR 181.500- Add 2 currently serviced portable fire extinguisher as described on COI
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 12 September 2020
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 August 2020
Resolved
46CFR182.530– Audible alarm was weak for forward high level alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 12 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 August 2020
Resolved
46CFR185.614- Add flare box of bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: ‘‘DISTRESS SIGNALS’’.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 12 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 August 2020
Resolved
46CFR185.604(f) The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Remark for 19 adult life jackets on top deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 12 September 2020
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 August 2019
Resolved
Vessels pre-engineered (Fireboy) fire extinguishing system protecting the machinery space does not shut down the main engine and does not meet the minimum standard of automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space in accordance with 46 CFR 181.420(a)(3). The vessel is restricted from carrying passengers until corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 September 2019
Resolution: Sat
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 20 August 2019
Resolved
Vessels Certificate of Documentation is expired, provide proof of application in accordance with 46 CFR 67.313. The vessel is restricted from carrying passengers until corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 September 2019
Resolution: Sat
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 August 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 25 September 2019
Resolution: Sat
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 August 2019
Resolved
Vessels bilge high level alarm in mid compartment were not operating properly and does not meet the standard of visual and audible alarm must be provided at the operation station per 46CFR182.530(a). The vessel will be restricted from carrying passengers after September 3, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 25 September 2019
Resolution: Sat
09 - Working and Living Conditions › 092 - Working Conditions › Stowage of cargo
Issued 20 August 2019
Resolved
Vessels food heater and refrigerator were not securely fastened to the bulkhead and at risk of tipping over and does not meet the minimum requirements as described in 46CFR176.830. The vessel will be restricted from carrying passengers after September 3, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 25 September 2019
Resolution: Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2019
Resolved
Vessels starboard side ventilation duct is combustible and does not meet the minimum requirements of 46CFR182.460. Replace duct with a non combustible material. The vessel will be restricted from carrying passengers after September 3, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 25 September 2019
Resolution: Sat
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 August 2019
Resolved
Vessels machinery space ventilation does not have a closure device and does not meet the minimum standard of provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent as described in 46CFR182.460. The vessel will be restricted from carrying passengers after September 3, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 25 September 2019
Resolution: Sat
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 20 August 2019
Resolved
Provide at least one crewmember on each vessel with CPR/First Aid training per NVIC 1-91. The vessel will be restricted from carrying passengers after September 20, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2019
Resolved 25 September 2019
Resolution: Sat
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 24 May 2018
Resolved
Properly mark the name of the vessel in at least four inch block letters on both sides of the bow in accordance with 46 CFR 67.123
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2018
Resolved 20 June 2018
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 May 2018
Resolved
Ensure all electrical outlets located on the weather decks in exposed locations have suitable watertight covers for protection against shock and damage in accordance with 46 CFR 183.210(b)
This deficiency was corrected prior to completion of the inspection.
Action required: 10 - Deficiency Rectified
Due 24 May 2018
Resolved 24 May 2018
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 24 May 2018
Resolved
Provide one additional portable fire extinguisher to protect the second deck passenger accommodation in accordance with the table in 46 CFR 181.500(b). Fire extinguisher must be classified as a 2-A.
This deficiency was corrected prior to completion of the inspection.
Action required: 10 - Deficiency Rectified
Due 24 May 2018
Resolved 24 May 2018
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 May 2018
Resolved
Install a new high level alarm float and demonstrate proper operation of the high level alarm, both visual and audible at the operating station in accordance with 46 CFR 182.530(a)(2) to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2018
Resolved 20 June 2018
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 17 May 2018
Resolved
Prior to credit for dry dock, install valves on the open through hull fittings in the sea chest located above the water line to prevent potential progressive down flooding to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2018
Resolved 24 May 2018
Construction/Loadline › Penetrations › Pipe Flange
Issued 17 May 2018
Resolved
Prior to credit for dry dock, remove three (03) plastic dead end caps in way of the thru hull fittings and replace with metallic, threaded caps to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2018
Resolved 24 May 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2018
Resolved
Prior to credit for dry dock, properly secure all loose and hanging wires and cables as identified throughout the vessel with metallic supports spaced not more than 24 inches apart in accordance with 46 CFR 183.340(b)(4) and to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2018
Resolved 24 May 2018
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 May 2017
Resolved
MAINTAIN CERTIFICATE OF DOCUMENTATION (COD) WITH "COASTWISE" ENDORSEMENT. 46 CFR 67.17 PRIOR TO CARRYING PASSENGERS
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 May 2018
Resolution: Received evidence COD now properly endorsed for Coastwise service.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 May 2017
Resolved
IMPLEMENT AND MAINTAIN DRUG AND ALCOHOL PROGRAM IAW 49 CFR 40. 46 CFR 16.201 46 CFR 16.240 PRIOR TO CARRYING PASSENGERS
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 August 2017
Resolution: DAPI program now in compliacne with 49 CFR 40.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 May 2017
Resolved
PROVIDE EVIDENCE/RECORDS OF FIRE FIGHTING, ABANDON SHIP, AND MAN OVERBOARD DRILLS. 46 CFR 185.520 / 46 CFR 185.524 46 CFR 185.420 PRIOR TO CARRYING PASSENGERS
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 August 2017
Resolution: Drills conducted and properly logged.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 23 May 2017
Resolved
REFIT/REPLACE DAMAGED MECHANICAL EXHAUST DUCT LOCATED NEXT TO THE PORT ENGINE. 46 CFR 182.460(a)(ii)PRIOR TO CARRYING PASSENGERS
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 August 2017
Resolution: Mechanical exhaust duct refitted.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 23 May 2017
Resolved
PROVIDE EVIDENCE THAT MECHANICAL BLOWERS PROVIDE ADEQUATE AIR EXCHANGE FOR ENGINE COMPARTMENT. 46 CFR 182.460(b)PRIOR TO CARRYING PASSENGERS
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 August 2017
Resolution: POC provided specs for both mechanical blowers, all sat.
Engineering › Fuel Oil Service System › Valve
Issued 23 May 2017
Resolved
INSTALL MANUALLY OPERABLE SHUTOFF VALVES FOR THE FUEL SYSTEMS ONBOARD. 46 CFR 182.455(b)(4)PRIOR TO CARRYING PASSENGERS
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 August 2017
Resolution: Manually operable shutoff valves installed and tested sat.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 23 May 2017
Resolved
PROVIDE EVIDENCE THAT FLAMMABLE VAPOR DETECTION SYSTEM MEETS REQS OF 46 CFR 182.480. 46 CFR 182.410(c)PRIOR TO CARRYING PASSENGERS
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 August 2017
Resolution: Specs provided for flammable vapor detection system, all sat.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 May 2017
Resolved
PROVIDE EVIDENCE/RECORDS OF CREW TRAINING THAT OCCURRED AT LEAST ONCE EVERY THREE MONTHS. 46 CFR 185.420 PRIOR TO CARRYING PASSENGERS
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 August 2017
Resolution: All crew training has been carried out and properly logged.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 23 May 2017
Resolved
PROVIDE RED WARNING SIGN FOR MECHANICAL BLOWERS AT THE CONTROL SWITCH. 46 CFR 182.460(e)
Due 22 June 2017
Resolved 29 August 2017
Resolution: Warning sign now posted.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 23 May 2017
Resolved
INSTALL MEANS OF CLOSING ALL SUPPLY DUCT DISCHARGE OPENINGS. 46 CFR 182.460(l)
Due 22 June 2017
Resolved 29 August 2017
Resolution: Means for closing supply duct now installed, tested, and found sat.
Engineering › Fuel Oil Service System › Valve
Issued 23 May 2017
Resolved
PROVIDE MARKING FOR FUEL SHUTOFF STATIONS. 46 CFR 185.608
Due 22 June 2017
Resolved 29 August 2017
Resolution: Onsite verfication, SAT
Engineering › Fuel Oil Service System › Hose
Issued 23 May 2017
Resolved
INSTALL TWO CLAMPS ON EACH FLEXIBLE HOSE IN AND AROUND THE ENGINE SPACE.
Due 22 June 2017
Resolved 29 August 2017
Resolution: Onsite verfication, SAT
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 May 2017
Resolved
PROVIDE WRITTEN PROPOSAL FOR MODIFICATIONS REQUIRED FOR CEILING HEIGHT IN PASSENGER ACCOMMODATIONS AROUND CEILING FANS. 46 CFR 177.800(b)
46 CFR 176.830
Due 22 June 2017
Resolved 29 August 2017
Resolution: Onsite verfication, SAT
Lifesaving › Hand Flares › Quantity
Issued 23 May 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 22 June 2017
Resolved 29 August 2017
Resolution: Onsite verfication, SAT
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 May 2017
Resolved
INSTALL GUARD/COVER AROUND ALL ROTATING MACHINERY. 46 CFR 177.960
Due 22 June 2017
Resolved 29 August 2017
Resolution: Onsite verfication, SAT
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 May 2017
Resolved
PROPERLY MOUNT BATTERIES IN ENGINE SPACE. 46 CFR 183.350(e)
Due 22 June 2017
Resolved 29 August 2017
Resolution: Onsite verfication, SAT
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 May 2017
Resolved
PROVIDE FIRST AID KIT WITH ALL REQUIRED EQUIPMENT. 46 CFR 184.710 46 CFR 160.041
Due 22 June 2017
Resolved 29 August 2017
Resolution: Onsite verfication, SAT
Fire Fighting › Fire Bucket › Quantity
Issued 23 May 2017
Resolved
PROVIDE EVIDENCE/RECORDS THAT VESSEL IS LOGGING WIND SPEED BEFORE DEPARTING. 46 CFR 176.110
Due 22 June 2017
Resolved 29 August 2017
Resolution: Onsite verfication, SAT
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 May 2017
Resolved
PROVIDE EVIDENCE/RECORDS THAT VESSEL IS LOGGING WIND SPEED BEFORE DEPARTING. 46 CFR 176.110
Due 22 June 2017
Resolved 29 August 2017
Resolution: Onsite verfication, SAT
Lifesaving › Lifebuoys › Serviceable
Issued 23 May 2017
Resolved
PROVIDE TYPE-II RETRO REFLECTIVE MATERIAL FOR REQUIRED RING LIFE BUOY. 46 CFR 185.604(h)
Due 22 June 2017
Resolved 29 August 2017
Resolution: Onsite verfication, SAT
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 17 June 2016
Resolved
Provide one additional orange smoke signal to ensure there are a minimum of three (03) red hand flares and three (3) orange smoke signals in accordance with 46 CFR 180.68.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2016
Resolved 25 July 2016
Resolution: One additional orange smoke signal was purchased and placed on board the vessel.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 June 2016
Resolved
Properly post the Certificate of Inspection under glass or other suitable transparent material so that all pages are visible and place in a conspicuous place on the vessel visible to passengers.
Action required: 705 - Other - as specified
Due 17 July 2016
Resolved 25 July 2016
Resolution: All pages of the COI were placed under glass and are in an area that is conspicuous to all passengers.
Documentation › Certificates/Documents › Stability Letter
Issued 17 June 2016
Resolved
Properly post the Certificate of Inspection under glass or other suitable transparent material so that all pages are visible and place in a conspicuous place on the vessel visible to passengers.
Action required: 705 - Other - as specified
Due 17 July 2016
Resolved 25 July 2016
Resolution: All pages of the stability letter were posted under glass near the operating station.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 June 2016
Resolved
Provide a current and valid Certificate of Documentation (COD) and ensure that the original COD is available on the vessel whenever underway. Company was having issues obtaining an initial COD. Deficiency has been extended to August 25th
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 23 August 2017
Resolution: Def re issued on 23MAY17, Vsl had COD onboard, but needs a COASTWISE endorsment.
Personnel › Training › Passenger Safety
Issued 17 June 2016
Resolved
Develop procedures to ensure an accurate, written count of all passengers is recorded on the vessel. Prior to departure on the voyage, the passenger count, including the number of crew members, must be communicated ashore and available to the Coast Guard upon request.
Action required: 705 - Other - as specified
Due 17 July 2016
Resolved 25 July 2016
Resolution: Passenger count procedures have been developed. See special note added to this inspection for further details.
Operations/Management › Passenger Operations › Safety Orientation
Issued 17 June 2016
Resolved
Prior to getting underway with passengers on board, the Master or another member of the crew, must make a public safety announcement and address all safety items as outlined in 46 CFR 185.506(a).
Action required: 705 - Other - as specified
Due 17 July 2016
Resolved 25 July 2016
Resolution: Master stated the safety orientation had been developed and will be done prior to every trip. Crew conducted the safety orientation in the presence of the attending Marine Inspector.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 June 2016
Resolved
Ensure the first aid kit has all the required contents in accordance with 46 CFR 160.041 and replace all expired medications. Deficiency has not been cleared. 835 has been extended until August 5, 2016.
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 9 September 2016
Resolution: Master provided a statement and photographic evidence that this item has been corrected.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 17 June 2016
Resolved
Post near the operating station Emergency Instructions containing the actions to be taken in the event heavy weather, fire and man overboard. The Master and crew must be familiar with the content of the posted Emergency Instructions.
Action required: 705 - Other - as specified
Due 17 July 2016
Resolved 25 July 2016
Resolution: Emergency Instructions were developed and posted for the crew.
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 June 2016
Resolved
Ensure all emergency drills (Fire, Abandon Ship and Man Overboard) are conducted and logged with all crew at least once every three months. Ensure emergency drills are conducted prior to getting underway with passengers after the vessel has been laid up for the off season.
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 9 September 2016
Resolution: Deficiency was cleared and a special note was added to the Vessel Critical Profile regarding the lack of training and emergency drills on the vessel.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 June 2016
Resolved
Mark the number on each life jacket storage locker with the total number of life jackets stowed within.
Action required: 705 - Other - as specified
Due 17 July 2016
Resolved 25 July 2016
Resolution: All life jacket lockers were stenciled with the total number of jackets contained within.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 June 2016
Resolved
Provide a floating water light in way of the life ring buoy that is approved under 46 CFR 161.010. The water light must have a lanyard of between 3 to 6 feet with a corrosion resistant clip and attached around the body of the buoy. In addition, the life ring buoy must be fitted with a life line of at least 60 feet.
Action required: 705 - Other - as specified
Due 17 July 2016
Resolved 25 July 2016
Resolution: Floating water light was provided and installed.
Engineering › Bilge Water Management System › Pump
Issued 17 June 2016
Resolved
Remove all electric submersible bilge pumps that are not UL approved and provide a bilge bump in each watertight compartment that meets the UL 1113 standard.
Deficiency has been extended an additional 30 days because of the lack of availability of the UL Approved Rule pumps.
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 9 September 2016
Resolution: Master provided a statement and photographic evidence that this item has been corrected.
Engineering › Bilge Water Management System › Valve
Issued 17 June 2016
Resolved
Provide a positive action valve at the hull penetration in way of the discharge hose for each electric submersible bilge pump in accordance with 46 CFR 182.520(e)(7).
Deficiency has been extended 30 days because the new pumps were just received by the owner.
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 9 September 2016
Resolution: Master provided a statement and photographic evidence that this item has been corrected.