Records from 2016 to 2025. Most recent: inspection, 23 April 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 30
23 April 2025
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8116515
18 April 2025
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8113905
9 May 2024
Administrative Inspection
Administrative · Activities Europe · Activity 7909674
2 April 2024
ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 7888466
13 November 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7824240
24 July 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7751689
6 March 2023
ACP COI Oversight · Re-Inspection
Physical examination · Activities Europe · Activity 7646043
14 February 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7636404
13 February 2023
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7636585
5 November 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7590285
14 February 2022
ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 7397648
11 June 2021
Administrative Inspection
Administrative · Activities Europe · Activity 7222076
23 April 2021
ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Activities Europe · Activity 7181162
24 July 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7024084
5 June 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6968697
5 June 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6974394
10 April 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6937935
11 March 2020
MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6919738
11 December 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6872930
10 September 2019
Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6808488
15 May 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6685095
26 February 2019
Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6632653
7 February 2019
Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6621930
17 December 2018
Annual Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6595244
23 August 2018
Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6520540
30 July 2018
Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6495389
8 May 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6409037
7 May 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6408464
23 August 2017
Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6251365
29 September 2016
Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6012525
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 April 2025
Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if fire occurs: structural fire protection, including fire resisting divisions, and protection of openings and penetrations in these divisions. Starboard Engine supply fan damper louvers fail M5, fail to close completely. Louvers remained at 4 inch opening between each bladed thought the outer mechanism indicated closed.
74 SOLAS(2020)II-2/14.2.1.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 23 April 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel has two 50-person life rafts port side main deck (mission deck), and two 50-person life rafts stbd side main deck (mission deck) that did not have their painter properly connected to the float free fusible link.
74SOLAS(2020)III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 April 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel has numerous
lifebuoy self-igniting light that did not function.
74SOLAS(2020)III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 23 April 2025
Resolved
A duplicate set of fire control plans shall be permanently stored in a prominently marked weather tight closure outside the deck house for the assistance of shore-side fire-fighting personnel. Vessel has three permanently stored fire control plans in weather tight closures on the main deck that are not prominently marked. Re-label fire control plans within 07 days.
74SOLAS(2020)II-2/15.2.4.2
Action required: 705 - Other - as specified
Due 30 April 2025
Resolved 2 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 23 April 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The anti-seasickness medicine in both lifeboats are expired.
74SOLAS(2020)III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2025
Resolved 1 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 23 April 2025
Resolved
Before giving approval to lifesaving appliances and arrangements, the Administration shall ensure that such lifesaving appliance and arrangements: are tested to confirm that they comply with the requirements of this chapter and the code. The four life jackets, located in the ECR, are approved to domestic voyage standards only as confirmed by the CG Approval Number 160.055 markings. For confirmed compliance with SOLAS and LSA Code, the life jackets must have CG Approval Number 160.155 marking.
74 SOLAS (2020)III/4.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2025
Resolved 1 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 22 April 2024
Resolved
Each liferaft or group of liferafts shall be stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the Code so that each floats free and, if inflatable, inflates automatically when the ship sinks. Vessel had 28 liferafts that did not have the painter properly connected to the float free fusible link.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 April 2024
Resolved 23 April 2024
Resolution: Received photographic evidence of painter lines being attached to fusible link on the HRUs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 April 2024
Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out based on the guidelines developed by the Organization* and in a manner having due regard to ensuring reliability of such appliances. Accumulator on the rescue boat davit showed signs of deterioration and was recommended by servicing company in December 2023 to be replaced within 3 months.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2024
Resolved 10 June 2024
Resolution: Class issued finding 549, ABS WO 6401085
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 April 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. FWD AFFF station had pump with hydraulic leak that was called out in servicing report in Jan 2024 to replace seal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2024
Resolved 10 June 2024
Resolution: Class issued finding 550, ABS WO 6401085
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2024
Resolved
Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights
complying with the requirements of paragraph 2.1.2 of the Code. Lifebuoys found on the stern and in the vicinity of the starboard lifeboat had lights that did not function.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2024
Resolved 25 April 2024
Resolution: Photographic evidence demonstrates lights are functioning.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 22 April 2024
Resolved
Information shall be posted in crew berthing areas and crew washing places for sexual assault and sexual harassment prevention policies and resources. Master key control logs shall be utilized for all master keys and duplicate cabin keys to single occupancy cabins. Update company SMS, logs and posted information. See USCG CVC Policy letters 23-04 & 23-06 for additional guidance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2024
Resolved 23 April 2025
Resolution: Vessel is in compliance with SASH
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 March 2023
Resolved
Stairways which penetrate only a single deck shall be protected, at a minimum, at one level by at least "B-0" class divisions and self-closing doors. Lifts which penetrate only a single deck shall be surrounded by "A-"0" class divisions with steel doors at both levels. Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-"0" class divisions and be protected by self-closing doors at all levels. The door from the stairtower to the starboard engine control room did not self close to the full closed position. Adjust door so it fully self closes.
SOLAS II-2/9.2.3.4.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 22 March 2023
Resolution: Door adjusted to self close properly.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 6 March 2023
Resolved
The training manual, which may comprise several volumes, shall contain instructions and information, in easily understood terms illustrated wherever possible, on the life-saving appliances provided in the ship and on the best methods of survival. Any part of such information may be provided in the form of audio-visual aids in lieu of the manual. The following shall be explained in detail: donning of lifejackets, immersion suits and anti-exposure suits. Training manual did not cover all lifejacket types. Incorporate all lifejacket type
donning instructiuons in the training manual.
SOLAS III/35.3.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 22 March 2023
Resolution: All lifejacket types are now incorporated into the SOLAS training manual.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 6 March 2023
Resolved
Fire hoses shall be of non-perishable material approved by the Administration and shall be sufficient in length to project a jet of water to any of the spaces in which they may be required to be used. Each hose shall be provided with a nozzle and the necessary couplings. Hoses specified in this chapter as "fire hoses" shall, together with any necessary fittings and tools, be kept ready for use in conspicuous positions near the water service hydrants or connections. Spanner wrench was missing at a fire station in the starboard engine room. Deficiency rectified on-site.
SOLAS II-2/10.2.3.1.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 18 March 2023
Resolved 18 March 2023
Resolution: Deficiency rectified on-site.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 5 November 2022
Resolved
The OCMI will determine the specific manning levels for vessels required to have certificates of inspection by part B of subtitle II of title 46 U.S.C. The masters or individuals in command of all vessels, whether required to be inspected under 46 U.S.C. 3301 or not, are responsible for properly manning vessels in accordance with the applicable laws, regulations, and international conventions. Vessel reports sailing short one Chief Engineer; return to full complement prior to sailing from port of call the vessel is arriving at on 11Nov2022.
Action required: 705 - Other - as specified
Due 20 November 2022
Resolved 13 November 2022
Resolution: Rcvd email attesting return to full crew complement.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 June 2020
Resolved
Pump used for sprinker system in the ammunition space overheated and taken out of service, to be cleared by class
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 5 June 2020
Resolved 17 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 March 2020
Resolved
At all times during voyage, all life saving appliances shall be in working order and ready for immediate use. Vessel's self igniting lights on the life buoy have expired batteries. 74 SOLAS (14) III/20.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2020
Resolved 23 March 2020
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 11 March 2020
Resolved
Fire protection shall be kept in good order so as to ensure their required performance. Vessel's fire doors are not closing properly. 74 SOLAS (14) II-2/14.2.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2020
Resolved 23 March 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 11 March 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2020
Resolved 10 April 2020
Resolution: Received evidence that [name withheld] maintains a current Coast Guard medical certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 17 December 2018
Resolved
Cargo ships shall carry at least one rescue boat. Current rescue boat is inoperable. Show proper operation of rescue boat to the satisfaction of the attending ABS surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 January 2019
Resolution: Closed in ABS report NN3605795. Rescue boat engine was examined by OEM tech and found to have no water ingress and electrical found dry. Vessel placed back in water and satisfactoritly tested. Rescue boat brought back onboard and stowed for sea.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 17 December 2018
Resolved
Fire damper for fan M3 does not operate as designed. Repair and show proper operation the the satisfaction of the attending ABS surveyor or CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 December 2018
Resolved 17 December 2018
Resolution: Fire damper for fan M3 was repaired and demonstrated proper operation to the attending CG marine inspector. Also cleared in ABS Report #NN3605795 (2JAN2019).