← All vessels
TAUGAS
TAUGAS is a 2015 tank ship. The Coast Guard has recorded 11 inspections since 2016, most recently in March 2025, along with 2 deficiencies and 1 operational control.
Records from 2016 to 2025. Most recent: inspection, 3 March 2025.
- Built
- 2015
- Last inspected
- 3 March 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 2 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9675080 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2GS2
1377776
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-1377776
Inspections, by type
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it13549 - Convention (Subpart B), Gross Ton
15134 - Dead Weight, Metric Ton
22520 - Displacement, Metric Ton
4065 - Convention (Subpart B), Net Ton
15134 - Dead Weight, Metric Ton
22520 - Displacement, Metric Ton
4065 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
3 March 2025
PSC B · COC-GAS Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8087117
11 April 2024
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7893446
5 April 2024
PSC B · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7887995
13 January 2023
COC-GAS Renew · Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7621056
2 December 2021
COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7358535
28 November 2020
Ballast Water Examination · COC-CHEM Renew
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7102557
18 October 2018
Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6563599
29 June 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6459779
18 March 2018
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6489281
20 February 2018
Deficiency Check · Ballast Water Examination · ISPS II Exam · In-Service Inspection · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6358227
8 January 2016
COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5794132
Deficiency record · 2
Deck/Cargo › Cargo Stowage › General
Issued 18 March 2018
Resolved
An audible and visual alarm system to give a warning on both sides of the airlock should be pro vided to indicate more than one door is moved from the closed position. Port State Control Officers discovered that neither visual or audible alarms activated inside or outside the space when both airlock doors were moved from the closed position. After this finding the crew replaced two fuses. The fuses burned out after testing airlock for second time. The fuses had been replaced with 2 amp instead of 3 amp. Once correct fuses were installed the airlock alarms operated satisfactory.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 10 March 2018
Resolved
-1160- HOLDS AND TANKS - Cargo tank liquid level gauge closed devices which penetrates the cargo tank but which form part of a closed system and keep the cargo from being released. Incomplete fusion; 8 inch separation of weld from based of liquid level gauge to tank dome was found on No.3 cargo tank, resulting in leakage of ethylene cargo.
74SOLAS(14CONS)VII/13.1 REF IGC 13.2.2.3
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.