Records from 2017 to 2026. Most recent: inspection, 14 April 2026.
Inspection history · 28
14 April 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8347217
21 May 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8139010
1 April 2025
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8100953
29 July 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7961433
6 May 2024
Drydock Exam · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7908127
18 May 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7691164
12 January 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7620117
28 April 2022
Plan Review "T" Boat
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7443803
10 March 2022
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7407452
30 July 2021
Deficiency Check · In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7272421
30 July 2021
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7351144
19 January 2021
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7120868
26 August 2020
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7042314
11 September 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6809675
20 May 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6688558
19 December 2018
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6600055
19 October 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6564381
1 October 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6553167
31 August 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6528580
16 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6513918
27 July 2018
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6492359
31 August 2017
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6256124
5 July 2017
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6197760
4 July 2017
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6199853
22 June 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6182929
15 May 2017
COI Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6142288
14 February 2017
Administrative Inspection · Construction Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6094104
19 January 2017
Construction Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6077531
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2026
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Vessel had insufficient SOLAS retroreflective material on ring buoy.
46 CFR 185.604(i)
Action required: 10 - Deficiency Rectified
Resolved 14 April 2026
Resolution: Approved retro-reflective tape added to ring buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 April 2026
Resolved
Each electric light intended as a Night Visual Distress Signal required by 33 CFR part 175 must be certified by the manufacturer as complying with the requirements of this subpart. Floating light had incorrect battery installed.
46 CFR 161.013-13
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 20 April 2026
Resolution: Received objective evidence battery replaced with valid and correct type.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 May 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit on board does have the required amount of medication as required by ISO 18813.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
Resolution: MI receieved photo of vessel having required amount of meds. on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 May 2025
Resolved
Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. A nozzle on a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, must:(1) Be of a type approved in accordance with approval series 162.027; or(2) Be of a type recognized by the Commandant as being equivalent in performance. Current fire hose nozzle on board can not be verified as an approved nozzle.
46 CFR 181.320 (d)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2025
Resolved 23 June 2025
Resolution: Vessel owner provided photo pfroof of approved nozzle on board; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 July 2024
Resolved
Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The retro-reflective tape on 37 life jackets was damaged, requiring repair. Passenger count reduced to 116.
705 - pax reduced to 116
46 CFR 185.604(h)
Action required: 705 - Other - as specified
Due 29 July 2024
Resolved 8 August 2024
Resolution: Type i retro-reflective material has been replaced. Passenger count has been return to the full effects of the COI.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 July 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The STBD aft window is a broken window with residual glass shards on the ground in the wheelhouse.
46 CFR 176.830(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 21 May 2025
Resolution: During annual inspection MIs verified window was replaced and glass shards were removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 June 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. STBD MDE water pump failed. 46 CFR 182.200(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 June 2024
Resolution: CG inspected new water pump installed and conducted operational test, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 June 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessels STBD shaft seal was overheating due to air in dripless shaft seal line.
Action required: 10 - Deficiency Rectified
Resolved 14 June 2024
Resolution: Vessel operator bled air from dripless shaft drain line and tested, all sat.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 10 March 2022
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel's FCC Safety Radiotelephony Certificate is expired.
47CFR90.903
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 March 2022
Resolution: Vessel has obtained the FCC radio certificate.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 10 March 2022
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Vessels starboard most aft sliding window is missing.
46CFR177.1020
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2022
Resolution: Starboard aft sliding window has been repaired/replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 March 2022
Resolved
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel was overdue for it's annual inspection required on 31MAY2021 based on the Certificate of Inspection issued on 31MAY2017.
46CFR176.500(b)(1)
Action required: 10 - Deficiency Rectified
Resolved 11 March 2022
Resolution: Owner/operator was informed to communicate via email to avoid any confusion in scheduling.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 30 July 2021
Resolved
A vessel must be provided with a steering gear of adequate strength. CG Marine Inspector notified of steering failure. Repair to the satisfaction of attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2021
Resolved 30 July 2021
Resolution: Attended vessel to conduct underway maneuvering tests to ensure satisfactory propulsion. Conducted ahead/astern and hard to port/starboard turns at full navigable speed. All test satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 August 2020
Resolved
Fixed-gas fire fighting system is outfitted with engine override. Engine override was not operable per fire servicing technician. Demonstrate operational test of system time delay, alarm, ventilation shutdown and engine override in accordance with approved manufacturer's testing procedure.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2020
Resolution: Fire servicing company demonstrated satisafcotry operation of vessel fixed fire system.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 September 2019
Resolved
Vessel must undergo an annual inspection within 3 months before or after the anniversary date. Vessel is overdue on its annual inspection based on the issued Certificate of Inspection date: 31 May 2017. Vessel must complete an annual COI inspection prior to carrying passengers.
(46 CFR 176.500 (b)(1))
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2019
Resolution: Conducted annual inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 September 2018
Resolved
Fixed fire extinguishing system's override for ventilation and engine control was inoperative. Troubleshoot and repair system to the satisfaction of attending CG Marine Inspectors.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2018
Resolved 1 October 2018
Resolution: Override system was repaired and tested to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 September 2018
Resolved
Steering system hydraulic ram was replaced as part of a repair or modification. Provide documentation indicating replacement in kind. Or, submit plans to the Marine Safety Center for review and approval.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 19 October 2018
Resolution: Steering drawings were approved by the Marine Safety Center as required.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 September 2018
Resolved
The conductor for the flexible, non-conducting, section of the fill pipe for the fuel tanks was not connected. Securely connect the conductor to the flexible section of the fuel fill pipe to the satisfaction of the attending CG Marine Inspector.
Condition: Improper Installation
Action required: 703 - Prior to bunkering operations
Due 21 September 2018
Resolved 1 October 2018
Resolution: Conductor was securely connected to the flexible section of the fuel fill pipe.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2018
Resolved
Electrical distribution panel located on the main deck in the electrical compartment is missing a dripshield. Install a dripshield at the distribution panel to the satisfaction of the attending CG Marine Inspector.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2018
Resolved 19 October 2018
Resolution: Dripshield was installed at the distibution panel in the electrical compartment.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2018
Resolved
The portable battery light at the access to the propulsion machinery space is missing. Replace light to the satisfaction of the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 1 October 2018
Resolution: Portable battery light was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 September 2018
Resolved
The lifejacket stowage in the wheelhouse had three lifejackets stowed inside, but was marked for ten. Replace the remaining seven lifejackets for the stowage location, or relabel the stowage to indicate the correct number of lifejackets stowed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 1 October 2018
Resolution: Lifejacket stowage was relabled to reflect the correct amount.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 August 2018
Resolved
Vessel must undergo an annual inspection within 3 months before or after the anniversary date. Vessel is overdue on its annual inspection based on the issued Certificate of Inspection date: 31 May 2017. Vessel must complete an annual COI inspection prior to carrying passengers. (46 CFR 176.500(b)(1))
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2018
Resolved 7 September 2018
Resolution: Vessel conducted annual examination.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 31 August 2018
Resolved
Vessel rep replaced leaking hydraulic rams on steering system. Repairs must be examined by CG Marine Inspectors and vessel must conduct sea trials to the satisfaction of the attending CG Marine Inspector prior to carrying passengers. (46 CFR 176.700(d))
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2018
Resolved 7 September 2018
Resolution: Marine Inspectors examined the new hyrdaulic rams and steering system as a whole. Conducted sea trials and found the system operating in a satisfactory condition.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 16 August 2018
Resolved
The vessel is currently broadcasting (1) Improper MMSI Number, (2) Improper Call Sign, (3) Improper Name, (4) Zero Length and Beam.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 September 2018
Resolved 6 March 2019
Resolution: Owner reported AIS discrepancies corrected. Used NAVCEN to verify accuracy of vessel's AIS broadcast.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 July 2018
Resolved
Observed cracked engine mount on staboard engine. Repair damaged engine mount and ascertain condition of remaining engine mounts to the satisfaction of the attending CG Marine Inspector.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2018
Resolved 17 August 2018
Resolution: Recieved letter from Volva Penta directing the removal of the motor mounts in question as they are deemed unecessary.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 July 2018
Resolved
Vessel operator is required to conduct and log rounds of the engine space once every hour to monitor condition/change of the engine mounts until repairs have been effected.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2018
Resolved 17 August 2018
Resolution: The issue with the motor mounts has been satisfactorily resolved following discussion with Volva Penta technical reps.
Engineering › Diesel Engine (propulsion-electric) › Gear/Clutch Starter (electric)
Issued 5 July 2017
Resolved
Vessels Starboard transmission gauge failed, locking transmission in neutral. Provide technician report and conduct power trials in the presence of attending USCG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2017
Resolved 12 July 2017
Resolution: Received technician's report attesting to the completed maintenance on the transmission. Conducted underway sea trials, all sat.
Engineering › Steering Gear System › Piping
Issued 5 July 2017
Resolved
Hydraulic steering gear fluid leaking from multiple locations, including but not limited to; a bulkhead penetration valve and the steering gear hydraulic ram. Additionally, there was significant pooling of hydraulic fluid in the bilge within multiple spaces. Clean bilges and make satisfactory repairs to steering system.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 28 July 2017
Resolution: Completed satisfactory sea trials and personally met with technician on board vesssel. Verified steering system did not exceed 1000psi.
Accommodation/Occupational Safety › Heating › Metal Protection
Issued 31 May 2017
Resolved
Insulation was missing on aft sections of port and stbd dry exhausts by flanges. Provide and instal insulation. 46CFR177.90.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 22 June 2017
Resolution: Insulation was added to entirety of port and starboard exhausts.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 31 May 2017
Resolved
COD contains incorrect tonnage and length. Provide corrected COD. 46CFR67.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 22 June 2017
Resolution: COD was corrected with updated tonnage and length.