ALLEGRO

ALLEGRO is a freight ship. The Coast Guard has recorded 38 inspections since 2016, most recently in March 2026, along with 28 deficiencies and 10 operational controls.

Records from 2016 to 2026. Most recent: inspection, 23 March 2026.

Built
Not recorded
Last inspected
23 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 March 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9142447
J8B5341
1378565
Flag
SAINT VINCENT AND THE GRENADINES
Maury page id
psix-1378565

Documentation record

Tonnage as PSIX records it4832 - Dead Weight, Ton
6613 - Displacement, Ton
2984 - Convention (Subpart B), Gross Ton
1311 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 38

23 March 2026 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8330184
7 July 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8178049
6 January 2025 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8058643
1 July 2024 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7946161
20 November 2023 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7826387
24 July 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7750975
25 March 2023 Ballast Water Examination · PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7655491
20 March 2023 PSC B · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7653225
6 February 2023 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7634886
19 December 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7611062
24 August 2022 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7542231
17 August 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7537006
10 June 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7472925
5 May 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7443272
5 April 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7425218
1 April 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7422720
16 March 2022 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7412380
16 September 2021 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7309700
9 March 2021 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7150889
15 September 2020 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7058544
2 September 2020 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7045696
21 July 2020 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7012368
29 February 2020 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6917808
15 August 2019 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6784063
7 February 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6621463
30 July 2018 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6495309
24 January 2018 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6342602
26 July 2017 PI Safety Exam · Ballast Water Examination · ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6219554
23 January 2017 PII Safety Exam · ISPS II Exam · Administrative Inspection · Ballast Water Examination · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6075211
12 January 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6069964
6 December 2016 In-Service Inspection · PII Safety Exam · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6052907
30 November 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6050033
29 November 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6048962
28 November 2016 Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6048386
28 November 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6049883
3 August 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5961193
11 April 2016 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5851201
29 January 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5806314

Deficiency record · 28

07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 1 July 2024 Resolved
A fireman's outfit shall consist of: Personal equipment comprising: Protective clothing of material to protect the skin from heat radiations from the fire and from burns and scalding by steam. PSCOs observed both fireman's outfits had exposed skin around the face, neck and ears. 74 SOLAS (97 Cons.) Ch II-2 Reg 17.1.1.1 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2024
Resolved 23 July 2024
Resolution: Resolved, received Dispensation Letter.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 20 March 2023 Resolved
Ships constructed on or after 1 October 1994... a second independent means of starting is provided in addition, a second source of energy shall be provided for an additional three starts within 30 minutes unless manual starting can be demonstrated to be effective. PSCO observed secondary means of start for emergency diesel generator was unable to start after 03 attempts. 74SOLAS(04 CONS)II-1/44.2.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2023
Resolution: Rectified. Received class report (RINA). New battery pack was installed and tested with good results.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 March 2023 Resolved
The life raft painter system shall provide a connection between the ship and the life raft and shall be so arranged as to ensure that the life raft when released and, in the case if an inflatable life raft, inflated is not dragged under by the sinking ship. PSCO observed painter line permanently affixed to the ship. 74SOLAS(97 CONS)III/38.6.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 20 March 2023
Resolution: Crew reconfigured painter line to attach to the weak link.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 August 2022 Resolved
he condition of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey, without the sanction of the Administration. Vessel reported overheating of the bio oil in the stern tube and replacement of the stern tube flanges. he condition of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey, without the sanction of the Administration. Vessel reported overheating of the bio oil in the stern tube and replacement of the stern tube flanges. he condition of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey, without the sanction of the Administration. Vessel reported overheating of the bio oil in the stern tube and replacement of the stern tube flanges. 74 SOLAS (Cons 20) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 21 August 2022
Resolved 22 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 16 March 2022 Resolved
DAVID LAUCHED LIFE RAFTS SHALL BE STOWED WITHIN REACH OF THE LIFTING HOOKS. PSCOS OBSERVED THE DAVIT LAUNCHED LIFERAFT STOWED ON THE PORT SIDE OF THE VESSEL AWAY FROM THE LIFTING HOOK OF THE DESIGNATED DAVIT LOCATED ON THE STARBOARD SIDE. 74 SOLAS(97 CONS) III/13.5
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 16 March 2022
Resolution: Vessel stowed liferafts in the correct locations to the satisfaction of the Coast Guard
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 March 2022 Resolved
CLEATS SHALL BE SET TO FIT THE TAPER OF THE WEDGES. THEY SHALL BE AT LEAST 65MM (2 1/2 INCHES) WIDE AND SPACED NOT MORE THAN 600 MM (13 1/2 INCHES) CENTRE TO CENTRE. PSCOS OBSERVED THE CARGO HATCH COVER CLEATS IN A CONCERNED STATE OF WASTAGE (CLEATS ARE STILL SERVICABLE) VESSEL HAS SUBMITTED A REQUEST WITH THE COMPANY FOR 46 NEW CLEATS AND ARE CURRENTLY AWAITING DELIVERY. ICLL 66/15.10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 10 June 2022
Resolution: PSCOs verified the conditions of all cargo hatch cleats were in a satisfaction condition. Vessel received new parts for cleats and had serviced all of them.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 16 March 2022 Resolved
ARRANGEMENTS SHALL BE MADE TO ENSURE IMMEDIATE AVAILABILITY OR A SURVEY OF WATER FROM THE FIRE MAIN AT THE REQUIRED PRESSURE EITHER BY PERMANENT PRESSURIZATION OR BY SUITABLY PLACED REMOTE ARRANGEMENTS FOR THE PUMPS. DURING THE TESTING OF THE EMERGENCY FIRE PUMP, PSCOS INFORMED THAT THE PUMP CAN ONLY BE STARTED LOCALLY. THE VESSEL IS AUTHORIZED TO CARRY DANGEROUS GOODS, AND PER REG II-2/2.4 OF SOLAS 74 (2020 CONS), VESSELS CONSTRUCTED BEFORE JULY 1, 2002 SHALL COMPLY WITH REG 19.3. 74 SOLAS (2020 CONS) II-2/19.3.1
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 5 May 2022
Resolution: USCG witnessed SAT test of remote start to the e-fire pump
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 16 March 2022 Resolved
IN ALL SHIPS GENERAL ARRANGEMENT PLANS SHALL BE PERMANETLY EXHIBITED FOR THE GUIDANCE OF THE SHIPS OFFICERS SHOWING CLEARLY THE VARIOUS FIRE SECTIONS....THE FIRE CONTROL PLAN HAS THE BULKHEAD BETWEEN THE STEERING RM AND ENGINGE RM MARKED AS OTHER DIVISON AND SHOWS OTHER DIVISIONS LINED THROUGH THE ENGINE RM WHERE THERE ARE NO BULKHEADS. "OTHER DIVISIONS" IS NOT A LISTED SYMBOL IN IMO RES A.654(16) FOR GRAPHIC SYMBOLS ON FIRE CONTROL PLANS. 74 SOLAS (1997 CONS) II-2/20.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 6 April 2022
Resolution: RO report dated 06APR22 confirming necessary updates have been made to reflect missing information and fire divisions.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 2 September 2020 Resolved
Vessel has a 3 foot small diameter hose attached after the oil content meter, but before discharge was used by crew to verify function. The modification was not reflected in an approved system diagram plan.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 15 September 2020
Resolution: Received class report attesting the testing valve installed by the crew is authorized.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 29 February 2020 Resolved
The structure, machinery and equipment...of and cargo ship...shall be subject to the surveys and inspections specified below. A minimum of two inspections of the outside of the ship's bottom during any five year period. Last entry for an inspection of the outside of the ship's bottom is dated 11JAN2016. Master was able to produce an inspection report confirming a satisfactory inspection on 07DEC2018. The corresponding endorsement for this inspection is missing from the vessel's Cargo Ship Safety Construction Certificate. 74 SOLAS (14) I/10(a)(v).
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2020
Resolved 3 March 2020
Resolution: Vessel was able to get a report from class proving they did have an inspection of the ship's bottom in the appropriate time frame prior to the inspection team departing. Class to correct the their oversight of failing to endorse the certificate.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 January 2017 Resolved
0920-Safety Plan-Fire Control Plan and booklets shall be kept up to date. FCP is missing marking for self-closing fire doors. 74 SOLAS (14 Cons) II-2/15.2.4.1;50ac
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 7 February 2017
Resolution: Recieved class report, please see attached in documents tab.
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 23 January 2017 Resolved
0670 - Portable Radio App. for Surv. Craft - On ships carrying two SARTS and equipped with free fall lifeboats one of the SARTS shall be stowed in a free fall life boat. Both SARTS were located on the bridge. 74 SOLAS (14 cons) III/6.2.2; 10c
Action required: 705 - Other - as specified
Resolved 24 January 2017
Lifesaving › Lifeboat Equipment › Seasickness Bag
Issued 23 January 2017 Resolved
0611 - Lifeboat inventory - Each survival craft shall be fully equipped as required by the code. Lifeboat does not have seas sickness medicine. 74 SOLAS (14 Cons) III/13.1.3; LSA Code 4.1.5.1.21; 16c
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 7 February 2017
Resolution: Recieved class report, please see attached in documents tab.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 6 December 2016 Resolved
Instructions for onboard maintenance of life saving appliances complying with the requirements of regulation 52 shall be provided and maintenance shall be carried out accordingly. PSCO found SART battery expired. Was previously identified by crew and passed to company three months prior. 74SOLAS (97) III/19.3.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2016
Resolution: Two new Sart batteries have been recieved onboard and replaced. See attached class report.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 6 December 2016 Resolved
Coaming and hatchway cover to exposed hatchwasy on deck above the superstructure deck shall comply with the requirements of the administration. PSCOs discovered temporary repairs made to cargo hatch gaskets on cargo bay number 27. ICLL Annex I/reg 14.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2016
Resolved 15 December 2016
Resolution: The cargo hatch gasket is permanently repaired and a hose test was carried out. See attached class report.
Lifesaving › Lifeboat › Propulsion Engine
Issued 6 December 2016 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCOs discovered that the vessel's freefall lifeboat engine did not start due to dead batteries. 74SOLAS (97) III/19.2
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 6 December 2016
Resolution: Corrected on spot.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 6 December 2016 Resolved
In the event of a power failure to any one of the steering gear power units, an audible and visual alarm shall be given on the navigation bridge. During the steering gear test, the power failure alarm did not give a visual or audible alarm on the bridge or in the steering gear room; the hydraulic level alarm sounded eratically on pump one when not being tested. 74SOLAS (04) II-1/29.5.2
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2016
Resolved 15 December 2016
Resolution: The power failure alarms have been permanently repaired. See attached class report
Lifesaving › Lifebuoys › Not on Board
Issued 6 December 2016 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO discovered that the vessel is missing two lifebuoys on the forward cargo deck, one having a self igniting light as per the fire control plan. 74SOLAS (97) III/19.2
Condition: Improper/Lack of Maintenance
Due 6 December 2016
Resolved 6 December 2016
Resolution: Vessel removed from bosun store and placed to proper location.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 6 December 2016 Resolved
The safety management system shall be maintained in accordance with the previsions of the international safety management code. Due to objective evidence discovered during an expanded ISM eam, it was identified that the vessel and company were not following proper shipboard and SMS procedures. Objective evidence found during the exam includes; See narrative
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2016
Resolution: SMS audit has been carried out and 6 nonconformities have been identified. See attached audit report.
Engineering › Steering Gear System › Rudder Stock
Issued 6 December 2016 Resolved
Whenever an accident occurs to a ship or a defect is discovered, the ship shall report at the earliest opportunity to the administration, the nominated surveyor, or recognized organization. Due to marine casualty in Port Everglades, vessel sustained damage to the rudder. Condition of class issued for a one time voyage to Sector Jacksonville. 74SOLAS (14) I/11(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2017
Resolution: Class report recieved from NKK.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 December 2016 Resolved
The machinery system and fittings shall be so installed and protected as to reduce to a minimum any danger to persons onboard, due regard being paid to hot surfaces. Number one generator exhaust lagging is missing and improper for intended use. 74SOLAS 9(7) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2016
Resolved 15 December 2016
Resolution: The exhaust lagging hass been installed and found in good order. See attached class report.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 6 December 2016 Resolved
After survey no changes shall be made of equipment or other items covered by the survey. Precautions against shock, fire, and other hazards of electrical origin. A portable A/C unit was installed in the engine control room, dripping condensation into a drip pan next to the switch board causing an electrical hazard. 74SOLAS (14) I/11(b) 74SOLAS 914) II-1/45
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2016
Resolved 15 December 2016
Resolution: The portable A/C unit has been removed. See attached class report.
Lifesaving › Inflatable Liferafts › Float Free
Issued 6 December 2016 Resolved
Liferafts complying with the requirements of regulations 39 or 40, on each side of the ship, of such aggregate capacity as will accommodate the total number of persons on board. The liferafts on at least one side of theship shall be served by launching appliances. PSCOs found neither liferafts on port or starboard side is of a davit launch type. 74SOLAS (97) III/26.1.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2016
Resolution: The starboard side life raft has been renewed with the proper davit launch type. See attached class report.
Fire Fighting › Fire Hoses › Location
Issued 6 December 2016 Resolved
Fire fighting systems and appliances shall be maintained ready for use. PSCOs discovered that fore-peak fire station was missing fire hose and not in accordance with fire control plan. 74SOLAS (14) II-2/14.1.1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 6 December 2016
Resolution: Deficiency rectified on the spot.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 28 November 2016 Resolved
The owner, master, or person in charge of each vessel underway shall ensure that the vessel's anchors are ready for letting go. The vessel is missing starboard anchor. 33CFR164.11
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 28 November 2016
Resolved 23 January 2017
Engineering › Generator (propulsion-electric) › Remote Control Circutry
Issued 28 November 2016 Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained. Vessel's unable to engage ahead propulsion. 74 SOLAS (04Con) II/1/26.3
Action required: 15 - Rectify deficiencies by next port
Resolved 3 December 2016
Resolution: Vessel submitted class report attesting to repairs.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 11 April 2016 Resolved
01FEB2016: 1030 - Hydraulic power-operated steering gear shall be provided with a low level alarm for each hydraulic fluid reservoir to give the earliest practicable indication of hydraulic fluid leakage. The vessel did not have means to demonstrate low level, due to build design. 74SOLAS (04) Ch.II-1/Reg.29.12.2 (50ac)
Action required: 705 - Other - as specified
Resolved 11 April 2016
Resolution: They rectified this by showing us they do have means to test the low level alarm and alarm going off on botht the bridge and in the engine room.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 1 February 2016 Resolved
1030 - Hydraulic power-operated steering gear shall be provided with a low level alarm for each hydraulic fluid reservoir to give the earliest practicable indication of hydraulic fluid leakage. The vessel did not have meant to demonstrate low level, due to build design. 74 Solas (04) Ch. II-1/Reg 29.12.2 (50ac)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 11 April 2016
Resolution: SEC MIA PSC attended vessel to make sure low level alarm works and could demonstrate its functionality. Alarm sounded on both bridge and in engine room.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.