MAURY USCG vessel records
← All vessels

INEOS INSPIRATION

INEOS INSPIRATION is a 2016 tank ship. The Coast Guard has recorded 27 inspections since 2016, most recently in March 2026, along with 6 deficiencies and 5 operational controls.

Records from 2016 to 2026. Most recent: operational control imposed, 23 March 2026.

Built
2016
Last inspected
23 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 March 2026
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9685451
9HA4150
1378594
Flag
MALTA
Maury page id
psix-1378594

Documentation record

Tonnage as PSIX records it22887 - Convention (Subpart B), Gross Ton
6866 - Convention (Subpart B), Net Ton
20916 - Dead Weight, Ton
32087 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

23 March 2026 PSC B · COC-GAS Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8330189
23 March 2026 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8330339
23 March 2026 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8346878
11 April 2025 COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8109030
10 August 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7978196
24 June 2024 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7941556
30 April 2024 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7904059
16 March 2024 PSC B · COC-GAS Renew · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7880152
27 March 2023 PSC B · COC-GAS Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7657439
21 February 2022 Administrative Inspection · COC-GAS Renew
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7398777
18 February 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7398506
7 April 2021 COC-GAS Annual · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7170244
11 December 2020 Type not recorded
No type recorded · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7110287
8 December 2020 In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7106132
24 August 2020 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7042152
30 January 2020 PSC B · COC-GAS Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6897599
25 March 2019 ISPS II Exam · COC-GAS Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6648381
18 July 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6484049
13 March 2018 Deficiency Check · Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6369041
28 July 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6223786
28 March 2017 ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6113007
26 October 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6029943
26 August 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5983853
23 June 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5916711
14 May 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5876685
4 May 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5869118
2 March 2016 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5822519

Deficiency record · 6

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 19 March 2024 Resolved
A gas carrier shall comply with the requirements of the international gas carrier code and shall... be certified as provided for in that code. Cargo emergency shutdown and alarm systems involved in cargo transfer should be tested and checked before cargo handling operations begin. PSCO observed crew unable to test cargo tank pressures IAW ships SMS because of lack of intrinsically safe pump unit.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2024
Resolved 30 April 2024
Resolution: Provided proof of purchase of intrinsically safe calibrator with approval from BV
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 13 March 2018 Resolved
-1138- LIQUEFIED GASES IN BULK - A certificate called an International Certificate of Fitness for the Carriage of Liquefied Gases in bulk should be issued to a gas carrier which complies with the relevant requirements of the Code. The ship's certificate of Fitness requires MARV setting adjusted to no higher than 7 bar for the port and starboard gaseous fuel deck tanks while carrying ethane. PSCO observed MARV settings adjusted to 08 bar on subject tanks. Vessel currently has ethane heel and is preparing to load ethane into deck tanks. 74SOALS(14CONS)VII/13.1. Ref: IGC CODE 1.5.4 50A/C
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 14 March 2018
Resolution: Received class report attesting to fact that deck tank MARVS have been set to 7 bar.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 13 March 2018 Resolved
02 -2545- REPORTS/ANALYSIS OF NON CORMITIES - The SMS should include procedures ensuring that non-conformities are reported to the company, investigated and analyzed. This should include procedures for the implementation of corrective action, including procedures intended to prevent reoccurrence. USCG Sector Houston-Galveston identified identical issue regarding MARV setting of deck fuel tanks during COC on JS INEOS INGENUITY in 2017. Evergas subsequently informed CG-HQ (CG-ENG-5) and Sector Houston-Galveston that this issue had been rectified fleet-wide. However, incorrect MARV was in use today. 74SOLAS(14CONS)IX/3.1 REF ISM 9 50C
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 3 April 2018
Resolution: Received internal incident report from company addressing corrective actions and actions to prevent recurrence.
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 13 March 2018 Resolved
03 -2535- DEVELOPMENT OF PLANS FOR SHIPBOAR OPS - The company should establish procedures for key shipboard operations. IGC 13.6.6 requires that fixed gas detection equipment testing and calibration be carried out at regular intervals and suitable span gas onboard. There are no ship=specific procedures regarding the testing of fixed gas detection. Furthermore, procedures from manufacturers provide contradictory guidance. Oldham sensor unit (from new construction) Malfunctioned in 2017 and was replace with Honeywell Sensor Unit. There are no manufacturers instructions for the Honeywell sensor onboard. Cargo [name withheld] states to test with 35% LEL propane, balance N2. Omicron (overall sampling system) stipulates to test with 50% LEL Butane. Develop procedures that correspond with onboard equipment. 74SOLAS(14CONS)IX/3.1 REF: ISM 7 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2018
Resolved 25 April 2018
Resolution: Existing methane-calibrated sensor was replaced with a propane-calibrated sensor by shoreside technician. Shipboard SMS procedure was revised to stipulate use of propane as span gas instead of methane.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 13 March 2018 Resolved
04 -1138- LIQUEFIED GASES IN BULK - Testing and calibration of fixed gas detection should be carried out at regular intervals in order to ensure the accuracy of the system. When PSCO requested to witness function of fixed gas detection system, crew applied 33% LEL propane span gas to sample point in cabinet. System read 77% LEL. Therefore, fixed gas detection system was out of calibration. 74 SOLAS(14CONS)VII/13.1 REF IGC 93/13.6 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 March 2018
Resolution: Vessel satisfactorily demonstrated high LEL alarms in the presence of attending PSCO.
Deck/Cargo › Cargo Condition › Bulk Liquefied Gas
Issued 28 July 2017 Resolved
PSC office received report from vessel that fixed gas detection system was unable to be properly calibrated. PSC Officers attended vessel, reviewed risk mitigation procedures, and witnessed unsuccessful span gas calibration of system. During attempted calibration, fixed gas detection was unable to detect above 11% LEL with 50% LEL span gas.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 August 2017
Resolution: See tech report attached to documents

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.