Inspection history · 16
9 September 2025
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8230315
14 May 2025
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8135609
20 September 2024
PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8003626
9 September 2024
PSC A · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7999123
2 June 2024
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7927361
1 June 2024
PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7924430
28 May 2024
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7921174
27 May 2024
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7933995
5 September 2023
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7784883
13 December 2021
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7362546
17 May 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6954735
13 February 2020
MARPOL Annex VI Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6908264
7 December 2018
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6585541
9 June 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6160368
17 September 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6002878
19 February 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5809880
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 September 2024
Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS.
PSCO OBSERVED ACCUMULATED POOLS OF DIESEL OIL AROUND ALL FUEL PUMPS AND CYLINDERS ON THE MAIN ENGINE.
74SOLAS(2020) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2024
Resolution: NKK: Checked all connections of fuel piping for F.O. injection pumps, tightened loosened
ones and placed anti-splashing tape on them as necessary. Removed all accumulated fuel oil and cleaned out all around F.O. injection pumps and cylinders of Main Eng
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 9 September 2024
Resolved
EVERY SHIP OF 100 GROSS TONNAGE AND ABOVE, AND EVERY SHIP WHICH IS CERTIFIED TO CARRY 15 OR MORE PERSONS, AND FIXED OR FLOATING FLATFORMS SHALL CARRY A GARBAGE MANAGEMENT PLAN WHICH THE CREW SHALL FOLLOW.
PSCO OBSERVED EXCESSIVE ACCUMMLATED GARBAGE IN CRANE STORE 1,2, AND 3 PILED TO THE OVERHEAD IN THE SPACE AND NO SEPARATED IN BINS PER THE VESSEL'S GARBAGE MANAGEMENT PLAN.
MARPOL ANNEX V 10.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2024
Resolution: Discharged garbage to the shore facility (Core Marine Services, Inc. Cleaned out all spaces and replaced all bins with new ones. It was confirmed that the newly collected garbage were properly separated and kept as per the Garbage Management Plan.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 September 2024
Resolved
ELECTRICAL SERVICES ESSENTIAL FOR SAFETY WILL BE ENSURED UNDER VARIOUS EMERGENCY CONDITIONS; AND THE SAFETY OF PASSENGERS, CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED.
PSCO OBSERVED 03 EMERGENCY LIGHTS NOT IN WORKING CONDITION. ADDITIONALLY 01 LIGHT ON THE STBD BRIDGE WING WAS BROKEN AT THE FRAME.
74SOLAS(20) 11-1/40.1.2,.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 September 2024
Resolution: Checked all lights installed outside of accommodation area, two (2) light assemblies
and three (3) bulbs were replaced with new ones.Electric cable's penetrating coaming pipes for all lights were checked,18 pcs were replaced, others derusted and painted.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 1 June 2024
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and operational nature of the deficiencies noted below provide objective evidence of a serious failure of the implementation of the ISM Code. An external audit report satisfactory to the Coast Guard must be submitted prior to clearance of this deficiency.
Action required: 30 - Ship detained
Resolved 9 June 2024
Resolution: NKK performed satisfactory audit of SMS.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 1 June 2024
Resolved
A ship when in a port of another Contracting Government is subject to control by officers duly authorized by such Government concerning operational requirements in respect of the safety of ships, when there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to the safety of ships. PSCO observed lack of crew familiarity with donning and using fire-fighting gear after multiple attempts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2024
Resolution: Master conducted additional firefighting training with crew to class satisfaction.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 1 June 2024
Resolved
Fire-fighters outfits shall comply with Fire Safety Systems Code. Personal equipment shall consist of protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. PSCO observed that the fire-fighter's outfits did not provide heat or fire protection for the neck. 74 SOLAS (20) II-2/10.10.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2024
Resolution: Company provided new firefighting suits to crew with head/neck protection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 1 June 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed improperly running lifeboat engine. After expanding into the lifeboat maintenance record, PSCO additionally found that lifeboat was reported inoperable on 19APR2024 but not reported repaired until 20MAY2024 despite the vessel being in active use in the intervening time frame. 74 SOLAS (20) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2024
Resolution: Engine fine speed control was tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 1 June 2024
Resolved
Each survival craft shall be stowed fully equipped as required by this chapter and the Code. PSCO observed a vessel-fabricated needle plug in place of the hydraulic release mechanism for the free-fall lifeboat. 74 SOLAS (20) III/13.1.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2024
Resolution: OEM needle plug was provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 June 2024
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. PSCO observed the fresh water generator was inoperable and disassembled. Fresh water generator is unable to produce an adequate amount of water for ships crew and operations on board. 74 SOLAS (20) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2024
Resolution: Vessel filled fresh water and potable water tanks to maximum using municipal water source. NKK requires repair of fresh water generator NLT 07AUG24.
09 - Working and Living Conditions › 091 - Living Conditions › Provisions quantity
Issued 1 June 2024
Resolved
Ships shall have on board food and water supplies which, having regard to the size of the crew and the duration and nature of the voyage, are suitable in respect to quantity, nutritive value, quality and variety. PSCO observed lack of sufficient quantity of potable water on board with 75 cubic meters in the potable water tanks and 288 liters of bottled water for the entire crew for a cross-Pacific voyage. ILO C147 pg.30,par.2; 46 USC 70002
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2024
Resolution: Vessel filled fresh water and potable water tanks to maximum using municipal water source.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 June 2024
Resolved
Stairways which penetrate only a single deck shall be protected, at a minimum, at one level by at least B-0 class divisions and self-closing doors. Lifts which penetrate only a single deck shall be surrounded by A-0 class divisions with steel doors at both levels. Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least A-0 class divisions and be protected by self-closing doors at all levels. PSCO observed one of the self-closing doors on the main stairway and the self-closing door in the fire control room for the emergency escape trunk to not be self-closing. One door labeled on the fire control plan as self-closing was not fitted with a self-closing device. 74 SOLAS (20) II-2/9.2.3.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2024
Resolution: The two doors requiring adjustment of the self-closing mechanism were adjusted, and the door requiring fitting of a self-closing mechanism was fitted with one.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 1 June 2024
Resolved
Ships shall be provided with arrangements, equipment and fittings of sufficient safe working load to enable the safe conduct of all towing and mooring operations associated with the normal operation of the ship. PSCO observed improper splicing on mooring line eye causing fraying. 74 SOLAS (20) II-1/3-8.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2024
Resolved 9 June 2024
Resolution: Line was re-spliced.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 June 2024
Resolved
Means shall be provided to limit the accumulation of flammable vapors. PSCO observed multiple fuel oil soaked laggings in the engine room along with fuel oil soaked rags. 74 SOLAS (20) II-2/4.1.2
Action required: 10 - Deficiency Rectified
Resolved 1 June 2024
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 1 June 2024
Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part I, so that all entries in the book appropriate to that operation are completed. Each completed operation shall be signed by the officer or officers in charge of the operations concerned and each completed page shall be signed by the master of the ship. PSCO observed completed page in Oil Record Book Part I not signed by the master of the ship. MARPOL I/17.4
Action required: 10 - Deficiency Rectified
Resolved 1 June 2024
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 1 June 2024
Resolved
Each discharge into the sea or to a reception facility, or a completed incineration, shall be promptly recorded in the Garbage Record Book and signed for on the date of the discharge or incineration by the officer in charge. Each completed page of the garbage record book shall be signed by the master of the ship. PSCO observed completed page in Garbage Record Book not signed by the master of the ship. MARPOL V/10.3.1
Action required: 10 - Deficiency Rectified
Resolved 1 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 June 2024
Resolved
Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights complying with the requirements of paragraph 2.12 of the Code. PSCO observed light not igniting on lifebuoy located on the port side main deck. 74 SOLAS (20) III/7.1.3
Action required: 10 - Deficiency Rectified
Resolved 1 June 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 5 September 2023
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or black on a light ground. PSCO observed paint on plimsol mark scratched off from wear, causing both the hull and plimsol mark to be the same color. The crew rectified this deficiency by painting plimsol mark white.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 5 September 2023
Resolved 5 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 December 2021
Resolved
11129 - Operational Readiness - Before the ship leaves the port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed that the free fall lifeboat did not start. Batteries are inoperable even though they are connected to charger and shore-tie cable. 74SOLAS(20)III/20.2 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2021
Resolved 14 December 2021
Resolution: Cleared deficiency with class report.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 December 2021
Resolved
07126 - Oil accumulaton in engine room. - Means shall be provided to control leaks of flammable liquids. PSCO discovered that number 1 booster fuel oil pump is actively leaking. Number 2 booster pump is leaking as well. 74SOLAS(20)II-2//4.1.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2021
Resolved 14 December 2021
Resolution: Cleared deficiency with class report.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 13 December 2021
Resolved
07117 - Jacketed high pressure lines - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ships or persons on board. PSCO discovered that number 4 cylinder has a leak on the high pressure hydraulic line and temp repairs were made to fix the leak. 74SOLAS(20) I/11.a - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2021
Resolved 14 December 2021
Resolution: Cleared deficiency with class report.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 December 2021
Resolved
07124 - Maintenance of Fire protection systems - Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO observed engineer testing the flame detector with a lighter. Manufacturer’s manual states “check and see if the detector operates properly by using a detector tester specified by NOHMI”. - 74SOLAS(20)II-2/14.2.2.1. - 15ac
Action required: 15 - Rectify deficiencies by next port
Due 13 December 2021
Resolved 14 December 2021
Resolution: Cleared deficiency with class report.