MAURY USCG vessel records
← All vessels

AFRICAN BUZZARD

AFRICAN BUZZARD is a 2014 freight ship. The Coast Guard has recorded 13 inspections since 2016, most recently in March 2026, along with 18 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: operational control imposed, 23 March 2026.

Built
2014
Last inspected
23 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 March 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9720225
1379137
Flag
PANAMA
Maury page id
psix-1379137

Documentation record

Tonnage as PSIX records it38202 - Convention (Subpart B), Gross Ton
21630 - Convention (Subpart B), Net Ton
66652 - Dead Weight, Metric Ton
78124 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

23 March 2026 Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8330814
5 June 2025 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8153207
15 January 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8064201
10 January 2025 PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8054222
7 March 2022 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7398415
6 March 2022 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7406812
29 February 2020 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6913161
29 February 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6918099
17 August 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6774299
3 April 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6116587
29 March 2017 COE-Dockside · Administrative Inspection · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6112953
25 March 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6108704
23 February 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5815647

Deficiency record · 18

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 March 2026 Resolved
Bulkheads at exposed ends of enclosed superstructures shall be sufficient const4ruction and shall be to the satisfaction of the administration. PSCO observed significant damage to the bow stem of the vessel as a result of a head on collision. Significant damage was sighted in the bosun hole including hole in bow. ICLL Annex I Reg 11 60ac
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 May 2026
Resolution: Reviewed and accepted class report from ABS. The report stated vessel received repairs from Buch Kreis for temporary side shell/stiffner support to the BOSUN hole.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 March 2026 Resolved
The administration shall satisfy itself that the general structural strength is sufficient for the draft corresponding to the freeboard assigned. PSCO observed starboard railing missing and buckling on the deck. ICLL Annex I Reg 1 60ac 60 ac
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 May 2026
Resolution: Reviewed and accepted class report from ABS. The report stated vessel received repairs from Buch Kreis and received new handrail system
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 23 March 2026 Resolved
To assist the casualty of investigations ships when engaged on international voyages subject to the provisions of regulation 1.4 shall be fitted with a voyage data recorder as follows: ships other than passenger ships of 3000 gross tonnage and upwards constructed on or after 1July2002. PSCO observed FCC code 106, could not record data. 74 SOLAS 2020 V/20.1.4 60ac
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 May 2026
Resolution: Reviewed and accepted class report from ABS. The report stated vessel received new VDR and it is working properly.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 23 March 2026 Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed, and manufactured in compliance with the structural, mechanical, and electrical requirements of a classification society which is recognized by the administration. PSCO observed starboard anchor with bent shank and fluke 74 SOLAS 20 II-1/3-1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2026
Resolution: Reviewed and accepted class report from ABS. The report stated vessel received ABD high power stockless anchor.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 February 2020 Resolved
07114-Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the Administration with a stored energy capability of at least three consecutive starts. A second source of energy shall be provided for an additional three starts within 30 minutes unless manual starting can be demonstrated effective. Emergency generator is missing batteries labeled #1 and therefore is not provided with a second source of energy for starting. 74 SOLAS (2014) II-1/44.2 60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2020
Resolution: New batteries have been procured & provided by the owner; charged overnight, tested and found in satisfactory operation for capability of three consecutives starts of the emergency generator, and an additional three starts as required.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 February 2020 Resolved
04103-In multi-engine installations which are supplied from the same fuel source, means of isolating the fuel supply and spill piping to individual engines shall be provided. The means of isolation shall not affect the operation of the other engines and shall be operable from a position not rendered inaccessible by a fire on any of the engines. Each quick closing fuel valve for the auxiliary engines was rendered not operational due to the valve mechanism being tied with cloth by the crew. Crew removed cloth and installed correct pins. 74 SOLAS (2014) II-2/4.2.2.5.5 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 February 2020
Resolution: Crew removed cloth and installed correct pins.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 17 August 2019 Resolved
The Company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of personnel, ship and protection of the environment. The various tasks should be defined and assigned to qualified personnel. Objective evidence found during an expanded ISM exam revealed that the vessel’s crew failed to follow the ship's SMS procedures with regard to fire-fighting procedures (SMS Section 10.1.1) and navigation safety (SMS Section 6). The crew failed two fire drills because they were not familiar with their duties, required fire-fighting equipment, and vessel fire-fighting procedures. Additionally, the crew failed to ensure that all ECDIS charts on board are corrected/up-to-date in accordance with SMS procedures. It is recommended that an external third party audit of the SMS be conducted with regard to deficiencies no. 3 and no.4 (ISM Code 7)
Action required: 30 - Ship detained
Due 17 August 2019
Resolved 28 August 2019
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. Additional fire drills were conducted until all crew were familiar with duties, equipment and procedures.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 17 August 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 30 - Ship detained
Due 17 August 2019
Resolved 28 August 2019
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. ISM Audit ensured that training was held to ensure proper inspection and maintenance of the ship and its equipment.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 17 August 2019 Resolved
A ship when in a port of another Contracting Government is subject to control by officers duly authorized by such Government concerning operational requirements in respect of the safety of the ships, when there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to the safety of ships. The vessel’s crew failed two fire drills because they were not familiar with their duties, required fire-fighting equipment, and vessel fire-fighting procedures. (74 SOLAS (14) XI-1/4.1)
Action required: 30 - Ship detained
Due 17 August 2019
Resolved 28 August 2019
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. Conducted training and fire drills with satisfactory results.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 17 August 2019 Resolved
Nautical charts and all other nautical publications necessary for the intended voyage shall be adequate and up to date. The vessel’s ECDIS charts (primary means of navigation) were not up to date during their inbound transit and remain in the same condition. (74 SOLAS (14) V/27)
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2019
Resolved 28 August 2019
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. Confirmed current ENC updates at time of survey.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 August 2019 Resolved
Each liferaft or group of liferafts shall be stowed with a float-free arrangement complying with the requirements or paragraph 4.1.6 of the Code so that each floats from and, if inflatable, inflates automatically when the ship sinks. The weak link for the hydrostatic release for the starboard side liferaft is disconnected due to corrosion on the liferaft cradle which compromises the approved float-free arrangement. (74 SOLAS (14) III/13.4.2)
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2019
Resolved 28 August 2019
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. Confirmed the liferaft cradle maintained properly and weak link has been connected as per instruction manual.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 17 August 2019 Resolved
Before the ship leaves port and at all times during the voyage all lifesaving appliances shall be in good working order and ready for immediate use. The port side embarkation ladder is missing several rubber spacers which hold individual steps in place and ensure personnel can safely embark the liferaft during an emergency abandon ship. In addition, the lines holding the rubber spacers in place on the starboard side embarkation ladder are in a severe state of degradation. (74 SOLAS (14) III/20.2)
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2019
Resolved 28 August 2019
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. Missing rubber spacers replaced on port side ladder. Starboard side ladder replaced with new ladder.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 17 August 2019 Resolved
Sanitary facilities for all members of the crew who do not occupy rooms to which private or semi private facilities are attached, shall be provided one water closet for every eight persons. Two of the three common toilets for 12 rated crew members were inoperable. Additionally, one of the three common showers for the 12 rated crew was inoperable. When asked, the C/O stated the sanitary facilities have been in this condition for at least five months. (ILO-147/PWSA 46 USC 70002)
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2019
Resolved 28 August 2019
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. Overhauled and adjusted flushing valve of toilet and position valve of shower. Tested with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 17 August 2019 Resolved
A fire-fighters outfit shall consist of protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. One fire-fighter's outfit was found with a one inch hold in the jacket. The vessel does not have the required number of fire-fighting outfits. (FSS Code 3.2.1.1.1, 74 SOLAS (09) II-2/10.10.1)
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2019
Resolved 28 August 2019
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. The fire fighter outfit was replaced with a new one.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 17 August 2019 Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ship’s officers, showing clearly for each deck the control stations, the various fire sections enclosed by “A” class divisions, the sections enclosed by “B” class divisions together with particulars of the fire detection and fire alarm systems, the sprinkler installation, the fire-extinguishing appliances, means of access to different compartments, decks, etc., and the ventilating system, including particulars of the fan control positions, the position of dampers and identification numbers of the ventilating fans serving each section. The vessel’s Fire Control Plan is not up-to-date and is missing information such as the location of the helideck, proper required number and locations of SCBAs, and proper required number and locations of fire-fighter outfits.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2019
Resolved 28 August 2019
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. Updated fire control plan properly for fire fighting appliances of helicopter facilities.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 17 August 2019 Resolved
Oil filtering equipment referred to in paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. In addition it shall be provided with alarm arrangements to indicate when this level cannot be maintained. The system shall also be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 ppm. The vessel’s Oil Content Meter is inoperable. The Panamanian flag state dispensation letter provided to PSCOs onboard expires August 30, 2019 and would expire before the vessel’s next intended voyage to South Korea. (MARPOL I/14.7)
Action required: 15 - Rectify deficiencies by next port
Due 17 August 2019
Resolved 28 August 2019
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. The defective OCM has been replaced new one. Carried out operation test with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 August 2019 Resolved
Means shall be provided to control leaks of flammable liquids. The no. 2 fuel oil purifier is leaking fuel oil as a result of two missing bolts from the flange connection to the sludge drain pipe creating a fire hazard. (74 SOLAS (09) II-2 4.1.1)
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2019
Resolved 28 August 2019
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. The missing bolts were restored to the flange and re-tightened.
Operations/Management › Ballast Water Managment › Alternative Management Method
Issued 29 March 2017 Resolved
9900- Vessel is outfitted with an approved alternative management system (AMS) described in 33 CFR 151.2025(a) (3), but failed to use the AMS while conducting a ballast water exchange prior to entry into US waters. Vessel is prohibited from discharging ballast water in US waters until one of the management requirements in 33 CFR 151.2025 is met.- 33CFR151.2025(a) C.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 6 April 2017
Resolution: PSC NOLA received a class report from NK satisfying the requirement.

Ownership record