Records from 2018 to 2025. Most recent: inspection, 15 October 2025.
Documentation record
Registered dimensions (L × B × D)70.0 ft × 30.0 ft × 9.8 ft
Registered tonnagegross 137 / net 110
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRODRIGUEZ SHIPBUILDING INC · CODEN, AL, UNITED STATES · built 2016
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portOSCEOLA, AR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 September 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it110 - Simplified, Net Ton
137 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 9
15 October 2025
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8249429
4 September 2024
Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7995917
2 October 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7801733
7 September 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7543586
20 October 2021
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7335153
24 September 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7067071
29 July 2020
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7019106
10 September 2019
Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6829831
6 August 2018
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6502532
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 October 2024
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket.
Three (3) life jackets need new lifejacket lights. One is expired, and two are two dim or inoperable. Replace lifejacket lights with approved lights.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2024
Resolved 23 October 2024
Resolution: New life jackets replaced and new lights replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 October 2024
Resolved
Each lifebuoy on a towing vessel must:(1) Be approved under approval series 160.050. In accordance with 160.050, each lifebuoy must have a synthetic grab line around the buoy.
Synthetic grab line around the lifebuoys are worn and frayed. Replace grab line around the lifebuoys and replace retroreflective tape that is sun-faded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2024
Resolved 23 October 2024
Resolution: Life buoys have been repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 September 2022
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in table 141.370.
Vessel had 04 red day/night VDS' onboard with an expiration date of DEC. 2021.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 September 2022
Resolution: Six red day/night signals are onboard; expire DEC 2023.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 September 2022
Resolved
Fuel Shut-off valve: The valve must be operable from a safe place outside the space where the valve is installed.
Fuel shut-off valve inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 September 2022
Resolution: Fuel shut-off valve was fixed and is operational.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 7 September 2022
Resolved
Required test and frequency: Pressure vessel relief valves shall be tested (02) twice in (05) five, no more than (03) three years elapsing since last test.
Relief valves were inoperable and exceeded the MAWP of 200 psi.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 September 2022
Resolution: Pressure relief valves have been replaced and are operational.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 September 2022
Resolved
All bilges and void spaces are to be kept free from accumulation of combustible and flammable materials and liquids insofar as practicable.
Remove excess oily waste in engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 September 2022
Resolution: Oily waste has been removed from engine room bilge.