Records in 2001. Most recent: inspection, 19 April 2001.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 19 April 2001
No resolution recorded
INITIATE TRAINING, DRILLS, AND INSPECTIONS IN ACCORDANCE WITH 46 CFR 109 SUBPART B.
Condition: Unknown
Due 19 May 2001 — due date passed with no resolution recorded
Documentation
Issued 19 April 2001
Resolved
PROVIDE CURRENT IOPP SUPPLEMENT TO IOPP CERTIFICATE.
Condition: Unknown
Due 3 May 2001
Resolved 14 August 2001
Lifesaving
Issued 19 April 2001
Resolved
PROVIDE COPY OF UPDATED STATION BILL.
Condition: Unknown
Due 3 May 2001
Resolved 14 August 2001
Electrical
Issued 19 April 2001
Resolved
PROVE PROPER OPERATION OF EMD GENERATORS REMOTE SHUTDOWNS ON FRONT OF HOUSEAND DRILL FLOOR.
Condition: Unknown
Due 3 May 2001
Resolved 14 August 2001
Electrical
Issued 19 April 2001
Resolved
PROVIDE MEANS TO ENSURE NEGATIVE VENTILATION IS MAINTAINED IN THE MUD PIT ROOM AT ALL TIMES. IF NEG VENTILATION IS DEPENDENT UPON POSITIVE PRESSURE IN ADJACENT SPACES, THEN THE LOSS OF POSITIVE PRESSURE MUST ALSO RESULT IN AN ALARM CONDITION JUST AS A LOSS OF NEG PRESSURE RESULTS IN AN ALARM.
Condition: Unknown
Due 3 May 2001
Resolved 14 August 2001
Fire Fighting
Issued 19 April 2001
Resolved
PROVIDE ADDITIONAL GENERAL ALARM BELLS AND GAILTRONICS SPEAKERS FOR MAIN DECK FORWARD AND AFT OF THE ACCOMIDATION SPACE.
Condition: Unknown
Due 3 May 2001
Resolved 14 August 2001
Electrical
Issued 19 April 2001
Resolved
PROVIDE SAFETY CABLES FOR FLOURESCENT FIXTURES IN ALL HAZARDOUS LOCATIONS.
Condition: Unknown
Due 3 May 2001
Resolved 14 August 2001
Construction/Loadline
Issued 19 April 2001
Resolved
PROPERLY PLUG ALL PENETRATIONS IN MUD PIT ROOM BULKHEADS.
Condition: Unknown
Due 3 May 2001
Resolved 14 August 2001
Lifesaving
Issued 19 April 2001
Resolved
REFILL EYEWASH STATION IN MUD PIT ROOM.
Condition: Unknown
Due 3 May 2001
Resolved 14 August 2001
Electrical
Issued 19 April 2001
Resolved
CLOSE ALL EXPLOSION PROOF BOXES ON DRILL FLOOR.
Condition: Unknown
Due 3 May 2001
Resolved 14 August 2001
Construction/Loadline
Issued 19 April 2001
Resolved
REPLACE DOOR GASKET IN MUD PIT ROOM DOOR.
Condition: Unknown
Due 3 May 2001
Resolved 14 August 2001
Electrical
Issued 19 April 2001
Resolved
PROVIDE EMERGENCY LIGHTING IN HOSPITAL SPACE.
Condition: Unknown
Due 3 May 2001
Resolved 14 August 2001
Engineering
Issued 19 April 2001
Resolved
RENEW LEAKING JACKET WATER HOSE ON #2 EMD FEED TANK TO WATER PUMP.
Condition: Unknown
Due 3 May 2001
Resolved 14 August 2001
Engineering
Issued 19 April 2001
No resolution recorded
REPAIR LUBE OIL LEAKS ON BOTH BLOWER ASSEMBLIES ON #3 EMD.
Condition: Unknown
Due 19 May 2001 — due date passed with no resolution recorded
Documentation
Issued 19 April 2001
No resolution recorded
SUBMIT EEP UPON ARRIVAL IN NEW ORLEANS [name withheld].
Condition: Unknown
Due 19 May 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 19 April 2001
No resolution recorded
PAINT AND PROPERLY PLACARD ALL FIXED CO2 REMOTE ACTIVATION STATIONS.
Condition: Unknown
Due 19 May 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 19 April 2001
No resolution recorded
PROVIDE PROOF OF HYDROSTATIC TEST OF ALL FIRE HOSES AT MAXIMUM OUTPUT, BUT IN NO CASE LESS THAN 100 PSI.
Condition: Unknown
Due 19 May 2001 — due date passed with no resolution recorded
Documentation
Issued 19 April 2001
Resolved
PROVIDE COPY OF FLAG ADMINISTRATION APPROVED SOPEP.
Condition: Unknown
Due 3 May 2001
Resolved 14 August 2001
Documentation
Issued 19 April 2001
Resolved
PROVIDE COPY OF APPROVED OPERATIONS MANUAL.
Condition: Unknown
Due 3 May 2001
Resolved 14 August 2001
Documentation
Issued 19 April 2001
Resolved
PROVIDE COPY OF APPROVED FIRE/SAFETY PLAN.
Condition: Unknown
Due 19 May 2001
Resolved 14 August 2001
Documentation
Issued 19 April 2001
Resolved
PROVIDE COPY OF APPROVED HAZARDOUS LOCATION PLAN.
Condition: Unknown
Due 19 May 2001
Resolved 14 August 2001