Records from 2021 to 2025. Most recent: inspection, 20 November 2025.
Inspection history · 7
20 November 2025
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8271558
9 November 2024
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8029266
10 April 2024
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7892990
22 June 2022
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7484461
9 January 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7377558
10 November 2021
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7348710
8 April 2021
Deficiency Check · PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7170461
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 November 2025
Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS PSCO OBSERVED HYDRAULIC FLUID LEAK FROM STEERING GEAR PUMPS POOLED IN THE MACHINERY SPACE. ADDITIONALLY, AND OIL DRAINAGE PIPE ON THE M/E HAD OIL-SOAKED LAGGING COLLECTED IN A CATCH BASIN.
74SOLAS(09) II-2/4.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 December 2025
Resolution: Recived DNV survey report. A running test of all hydraulic pumps was conducted, and no leakage was observed. The lagging on the oil drainage pipe of the main engine was repaired by the crews and found to be in satisfactory condition.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 November 2025
Resolved
"A" CLASS DIVISIONS ARE THOSE DIVISIONS FORMED BY BULKHEADS AND DECKS WHICH COMPLY WITH THE FOLLOWING CRITERIA: THEY ARE SO CONSTRCUTED AS TO BE CAPABLE OF PREVENTING THE PASSAGE OF SMOKE AND FLAME.
PSCO OBSERVED EMERGENCY ESCAPE FIRE DOOR IN ENGINE ROOM NOT ABLE TO LATCH.
74SOLAS(09) II-2/3.2.4
Action required: 10 - Deficiency Rectified
Due 20 November 2025
Resolved 20 November 2025
Resolution: CREW WAS ABLE TO REPAIR THE LATCH DURING EXAM.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 November 2021
Resolved
02-108-Structrual Conditions: All electrical apparatus shall be so constructed and soinstalled as not to cause injury when handled or touched in the normal manner. PSCO observed the housing on multiple deck lighting fixtures to be cracked/missing. 74SOLAS(09) II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 December 2021
Resolution: Vessel sent report of rectified deck lighting fixtures.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 April 2021
Resolved
Hydrostatic release units shall be serviced at intervals not exceeding 12 months.
Both hysdrostatic releases for the EPIRD and SART (**VDR) expired in March 2021.
74 SOLAS (14) III/20.9
ACTION TAKEN: c
** There was a typo on Form B for this deficiency. SART was satisfactory and the VDR hydrostatic release was expired.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2021
Resolved 9 April 2021
Resolution: MSC SONIA recieved new hydrostatic units and replaced the expired ones.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2021
Resolved
Personnel equipment shall consist of the following: protective clothing of material to protect the skin from the heat radiating from the fire.
Fireman's outfit exposes individual wearing it's skin.
74 SOLAS (20) II-2/10.1.1 FSS Code 3.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 April 2021
Resolved 19 August 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2021
Resolved
Cylinders must be stowed and secured when not in use in a rack and upright.
Oxygen and acetylene bottles stored loosely in the same locker.
46CFR147.60(b)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 April 2021
Resolved 8 April 2021
Resolution: Crew seperated bottle types and properly secured them.