MAURY USCG vessel records
← All vessels

BACKWATER

BACKWATER is a 2016 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in March 2026, along with 12 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 30 March 2026.

Built
2016
Last inspected
30 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDI7859
1379944
Flag
UNITED STATES
Maury page id
psix-1379944

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 11

30 March 2026 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8333039
22 May 2025 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8141476
7 March 2024 Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7870180
9 May 2023 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7683717
8 March 2022 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7407272
16 March 2021 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7139891
10 March 2020 Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6903144
4 March 2019 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6620515
20 March 2018 Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6362358
16 February 2017 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6089382
10 February 2016 COI Inspection · Initial Certification · Construction Oversight
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5812935

Deficiency record · 12

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 April 2021 Resolved
Renew life ring and properly mark.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 10 May 2021
Resolution: The ring buoy was renewed and properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 April 2021 Resolved
Install retro-reflective tape on secondary life ring buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 10 May 2021
Resolution: Retro reflective tape was properly installed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 April 2021 Resolved
Provide updated coast pilot and light list onboard vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 10 May 2021
Resolution: All nav pubs were provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2021 Resolved
Properly label fuel cut off valve.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 10 May 2021
Resolution: Fuel cut off valve was labled.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 April 2021 Resolved
Provide radio telephony safety certificate.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 10 May 2021
Resolution: Provided radio telephony safety certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 April 2021 Resolved
Renew all fuel hoses with marine grade type.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 10 May 2021
Resolution: All fuel hoses were renewed with marine grade type.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 March 2019 Resolved
Renew P&S fuel tanks due to cracks resultant from UV damage. Renew prior to 04APR19.
Condition: Damaged By Earlier Event
Due 4 April 2019
Resolved 20 March 2019
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 10 February 2016 Resolved
Mark fuel shut-off valve w/ direction of closure.
Due 25 May 2016
Resolved 31 May 2016
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 10 February 2016 Resolved
Provide no smoking placards
Due 25 May 2016
Resolved 31 May 2016
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 10 February 2016 Resolved
Provide lifejacket donning placard
Due 25 May 2016
Resolved 31 May 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 February 2016 Resolved
Provide battery boxes.
Due 25 May 2016
Resolved 31 May 2016
Operations/Management › Log/Records › Ballast Water Logs/Records
Issued 10 February 2016 Resolved
Provide training logbook
Due 25 May 2016
Resolved 31 May 2016

Ownership record