Records from 2016 to 2026. Most recent: inspection, 28 April 2026.
Documentation record
Registered dimensions (L × B × D)34.3 ft × 10.6 ft × 6.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2016
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
28 April 2026
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8345046
27 February 2026
Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8312382
27 June 2025
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8160689
24 July 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7965456
20 February 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7866269
11 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7679580
19 April 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7435843
8 March 2022
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7408341
29 April 2021
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7179479
20 July 2020
Drydock Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7009089
7 April 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6936787
2 January 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6882423
10 October 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6831825
13 September 2019
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6813104
21 May 2019
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6689000
15 May 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6415267
26 April 2018
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6395914
16 May 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6144957
27 February 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6095584
18 January 2016
Internal Structural Exam · Initial Certification · Construction Oversight · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5813225
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 April 2026
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made with the approval of the cognizant OCMI.
A crack was identified on the port end of the outside rail of the swim step. Provide repair proposal for review and approval of attending marine inspector. Once approved, restore to the satisfaction of the attending marine inspector prior to receiving credit drydock.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 14 April 2026
Resolution: Repair approved by the attending marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 June 2025
Resolved
"A vessel must comply with the applicable requirements for any radio...including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80." The FCC Safety Radiotelephony Certificate found expired.
46 CFR 184.502
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2025
Resolved 3 July 2025
Resolution: Vessel representative provided signed copy of FCC Radiotelephony Certificate.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 June 2025
Resolved
"A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have...an audible alarm that sounds upon discharge." No audible alarm witnessed by MI.
46 CFR 181.420(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 June 2025
Resolution: Vessel rep replaced old switch and conducted operational test with MI present. Audible alarm heard and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2025
Resolved
"A vessel not required to have a power driven fire pump must have at least three 9.5 liter buckets with an attached lanyard." 01 fire bucket found to be broken with no lanyard attached.
46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 June 2025
Resolution: Vessel rep re-attached the lanyard to the fire bucket and demonstrated proper use.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 June 2025
Resolved
"A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided." 01 child life jacket found defective.
46 CFR 180.71(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 June 2025
Resolution: Destroyed and disposed of on-site. Replaced in kind while MI present.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 June 2025
Resolved
"At least one ring life buoy must be fitted with a lifeline...be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light." MI witnessed lifeline attached to ring buoy was not dark in color/resistant to UV light or non-kinking.
46 CFR 180.70(c)(6)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 27 June 2025
Resolution: Vessel rep replaced with new non-kinking, dark in color lifeline.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 April 2022
Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. All navigation lights were inoperable. Provide navigation lights that are in compliance with the Navigation Rules.
46 CFR 183.420
Action required: 10 - Deficiency Rectified
Resolved 19 April 2022
Resolution: Navigation lights operable.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 April 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked "First-Aid Kit". A first-aid kit must be easily visible and readily available to the crew. First aid kit is incomplete. Provide USCG-approved kit or a kit that complies with the list in 46 CFR 160.041.
46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2022
Resolved 16 May 2022
Resolution: Added iodine and ophthalmic ointment.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 April 2022
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant [name withheld] buckets were 3 1/2 gallons. Drill holes to 2 1/2 gallons or provide 2 1/2 gallon buckets with lanyards.
46 CFR 181.610
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2022
Resolved 16 May 2022
Resolution: Acquired fire buckets and provided picture.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2021
Resolved
Electrical equipment must be installed to protect from electrical hazards. Corrosion observed on terminations of conductors in electrical panel.
46 CFR 183.200.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 25 May 2021
Resolution: Vessel cleaned terminations.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 April 2021
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Bilge alarms not labeled for identification.
46 CFR 182.530(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 25 May 2021
Resolution: Alarms labled.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2021
Resolved
When the flexible section (of a fuel fill pipe) is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. Port fuel tank grounding conductor not attached to fill fitting.
46 CFR 182.445(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 25 May 2021
Resolution: Grounding conductor reattached.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 April 2021
Resolved
If posting of the stability letter is impracticable, the stability letter must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request. Vessel did not have stability letter on the vessel.
46 CFR 176.306
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 25 May 2021
Resolution: Vessel provided stablility letter on vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2021
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Provide record of supervisors receiving 60 minutes of EAP training.
46 CFR 16.401 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 25 May 2021
Resolution: Vessel sent records of completed EAP training.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2021
Resolved
As an employer, you must keep the following records for the following periods of time: You must keep the following records for five years: Records of verified positive drug test results. You must keep the records of negative and canceled drug test results and alcohol test results with a concentration of less than 0.02 for one year. Provide records of positive/ negative results.
49 CFR 40.333 (a)
Action required: 705 - Other - as specified
Due 29 May 2021
Resolved 25 May 2021
Resolution: Vessel provided records of test results.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 July 2020
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Onboard portable and fixed extinguishers were overdue for required annual servicing. Provide annual servicing report from a State or local jurisdiction certified fire extinguisher servicing agency.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vsl completed annual fire extinguisher servicing.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 20 July 2020
Resolved
A certification that the ship has passed an inspection must be entered into the ship's log by the inspecting technician. A FCC Safety Radiotelephony Certificate (SRC) was not onboard. Provide a valid SRC onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vsl has valid FCC Safety Radiotelephony Certificate onboard.