AFRICAN FINFOOT is a 2015 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in September 2024, along with 6 deficiencies and 1 operational control.
Records from 2016 to 2024. Most recent: inspection, 17 September 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it34773 - Convention (Subpart B), Gross Ton 20193 - Convention (Subpart B), Net Ton 61219 - Dead Weight, Metric Ton 72322 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 9
17 September 2024PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7993632
27 May 2021PSC B · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7199089
14 October 2018ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6550753
21 November 2017Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6310602
21 November 2017Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6315237
14 August 2017Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6229866
12 August 2017Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6238236
3 August 2017Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6229905
10 May 2016Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5861946
14104 - Oil filtering equipment shall be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content othe effluent exceeds 15 PPM. The administration shall have regard to the specification recommended by the organization. PSCO observed that OWS content meter read "CALIBRATION OVERDUE."
MARPOL I / 14.7
17ABC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2021
Resolution: Flag/class approved repairs.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 May 2021Resolved
15109 - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. PSCO discovered the #1 turbo on generator was overhauled on 04MAR2021 but the crew failed to replace O-ring in the lubricating fitting of turbo.
SOLAS cons. 2020 IX / reg 3.1
ISM 10.1
17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2021
Resolution: Repairs approved by Class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 May 2021Resolved
13102 - The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected to reduce to a minimum any dangerto persons on board. PSCO observed an active leak on #1 turbo for its corresponding generator. Oil pooled under trubo with a depth of 1/4 inch.
SOLAS cons. 2020 II-1 /reg.26.1
17 AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2021
Resolution: Repairs approved by Class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 May 2021Resolved
13101 - The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected to reduce to a minimum any dangerto persons on board. PSCO observed an active fuel oil leak on #3 fuel injector on the main engine. Fuel oil pooling around cylinder head and behind cylinder.
SOLAS cons. 2020 II-1 / reg. 26.1
17 AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2021
Resolution: Repairs approved by Class.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 May 2021Resolved
07126 - The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. Means shall be provided to control leaks of flammable liquids. PSCO observed a bilge well aft of the main engine with 5 inches of black fuel oil. Additionally, PSCO discovered that beneath the main engine is littered with oily rags and lube oil.
SOLAS cons. 2020 II-2 / reg. 4.1.1
17 AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2021
Resolution: Repairs approved by Class.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 May 2021Resolved
99101 - NOA must contain all the information items specified in table 126.206. Vessel did not report cargo nor if the vessel had any ballast on board.
33 CFR 160.206 (a)
10C
Action required: 10 - Deficiency Rectified
Resolved 1 June 2021
Resolution: Repairs approved by Class.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National