MAURY USCG vessel records
← All vessels

SKYVIEW

SKYVIEW is a 2016 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2016, most recently in May 2026, along with 15 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 14 May 2026.

Built
2016
Last inspected
14 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDI 9084
1380359
Flag
UNITED STATES
Maury page id
psix-1380359

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)95.5 ft × 35.0 ft × 7.5 ft
Registered tonnagegross 90 / net 90
ITC dimensions (L × B × D)95.5 ft × 35.0 ft × 7.5 ft
ITC tonnagegross 189 / net 88
BuilderBLOUNT BOATS INC · WARREN, RI, UNITED STATES · built 2016
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it189 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
88 - Convention (Subpart B), Net Ton
90 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 25

14 May 2026 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8370734
6 March 2026 Drydock Extension
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8324943
24 September 2025 Plan Review (Other than "T")
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8240179
14 April 2025 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8111225
12 July 2024 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7956673
30 May 2024 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7923485
25 April 2024 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7901217
23 May 2023 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7694560
17 June 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7480266
2 June 2022 Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7466029
15 April 2021 MTSA Verification · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7175548
16 March 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7157187
4 June 2020 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6968334
15 April 2019 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6663144
17 August 2018 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6524485
21 May 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6419794
8 June 2017 DAPI Audit · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6169822
17 February 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6090182
5 December 2016 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 6052439
7 September 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5995305
23 August 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5980713
15 August 2016 Plan Review (Other than "T")
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5975286
1 August 2016 MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5959089
22 July 2016 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 5949299
19 February 2016 Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5818223

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 June 2022 Resolved
The escape hatches for the engine compartment and bar/machinery space are not marked on both sides. Mark the inside of both hatches "Emergency Exit, Keep Clear" in block letters at least 2" high.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 2 July 2022
Resolved 17 June 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 June 2022 Resolved
The #1 fire station valve stem is leaking. Make necessary repairs to the valve to correct the leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 17 June 2022
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 2 June 2022 Resolved
The passenger seating on the main deck is missing five bolts. Several nuts are loose. Replace all missing bolts and tighten others as applicable.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 17 June 2022
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 August 2016 Resolved
Properly label remote fuel shut off 1 inch lettering per 46 CFR 122.608
Condition: Placed in Improper Service
Due 5 September 2016
Resolved 23 August 2016
Electrical › Electric Generation Source (service) › Power Requirement
Issued 1 August 2016 Resolved
Provide proof all electric motors in engineroom comply with 50c rating per 46 CFR 120.320
Condition: Improper Installation
Due 5 September 2016
Resolved 23 August 2016
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 1 August 2016 Resolved
Troubleshoot and correck cause of shaft howling (both shafts) per 46 CFR 115.804 and 115.840
Condition: Design Flaw
Due 5 September 2016
Resolved 23 August 2016
Stability › Incline Test › General
Issued 15 July 2016 Resolved
Provide approved stability letter
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2016
Navigation › Piloting/Steering › Marine Charts
Issued 15 July 2016 Resolved
Provide Navigation publications
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2016
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 15 July 2016 Resolved
Resubmit/ Revise PSTP- Test #3; Neutral Safety Switch
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2016
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 July 2016 Resolved
Provide Fire Safety Plan for approval
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2016
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 July 2016 Resolved
Install seating;verify egress; verify seat spacing
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2016
Communications › Public Address System › Loudspeaker
Issued 15 July 2016 Resolved
Test PA system
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2016
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 July 2016 Resolved
Provide proof of DAPI program
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 July 2016 Resolved
Provide COD
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 February 2016 Resolved
Complete drills for MOB, Fire and abandon ship
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.