Records from 2016 to 2026. Most recent: inspection, 6 May 2026.
Documentation record
Registered dimensions (L × B × D)36.0 ft × 14.0 ft × 7.0 ft
Registered tonnagegross 23 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2016
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Gross Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
6 May 2026
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8354148
5 November 2025
Deficiency Check · Drydock Exam · Examination of Repairs · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8267537
18 September 2025
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8235453
13 July 2025
Type not recorded
No type recorded · Station San Juan · USCG Southeast District (CGD-SE) · Activity 8185051
11 September 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7999922
28 November 2023
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7830363
13 September 2023
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7780599
14 September 2022
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7548569
5 November 2021
Drydock Exam · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7345816
21 June 2021
DAPI Audit · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7231301
5 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6966897
10 December 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6868486
26 June 2019
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6725292
19 June 2018
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6448539
4 April 2018
Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6384855
7 October 2017
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6288652
19 June 2017
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6180107
7 December 2016
Simplified Stability Test
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6056821
21 June 2016
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5913998
4 April 2016
Plan Review "T" Boat · Drydock Exam · Internal Structural Exam · Inclining Experiment · COI Inspection · Simplified Stability Test · Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5846795
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 November 2025
Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Connections on batteries should be limited to no more than 4 per terminal. 46 CFR 176.800(a)/ ABYC E-11. Code 705C Prio dry dock credit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2025
Resolved 20 November 2025
Resolution: A new cable distribution strip was installed, with only two batery cables connected to the battery.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 September 2024
Resolved
Except as allowed by paragraph (d) of this section, each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.155 or 160.176. 07 adult life jackets were found to be sun damaged and unserviceable. Replace in kind.
46 CFR 180.71 (c)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2024
Resolved 12 September 2024
Resolution: New adults 07 PFD were pruchased, placed on board and marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 September 2024
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: The pump activation float is not permanently mounted. Attach activation float permanently to hull.
46 CFR 182.520 (e)(3)
16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2024
Resolved 12 September 2024
Resolution: Submersible bilgepump was secured permanently to the hull.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 September 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Except as allowed by paragraph (d) of this section, each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter.
08 life jackets were deteriorated and unusable due to sun exposure. Replace in kind. Maximum passenger count is reduced to 18.
46 CFR 180.71
50C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 September 2023
Resolution: Life jackets replaced. Passenger count back to normal.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 September 2023
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must: Be buoyant; Be of at least 18.3 meters (60 feet) in length; Be non-kinking; Have a diameter of at least 7.9 millimeters (5/16 inch); Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light.
Ring life buoy's lifeline was deteriorated. Replace in kind.
46 CFR 180.70
50C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2023
Resolution: New life line replaced. Verified by inpsector.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 13 September 2023
Resolved
The float-free link required by § 180.130(a)(1) must be: (1) Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant;
Vessel equipped with new life float but does not have weak link for painter. Install weak link specific for installed float-free life float.
46 CFR 180.137
50C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2023
Resolution: Master discovered that weak link was not missing but hidden under painter braket.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 5 June 2020
Resolved
A vessel must have an approved life float. Inspectors
found several cracks on life float. Vessel is restricted
to 3 nautical miles until cleared.
Action required: 705 - Other - as specified
Due 5 July 2020
Resolved 20 August 2020
Resolution: Master told that life float repair will be monitored on an annual basis to ensure proper maintenance. Special note added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 June 2020
Resolved
Fuel shut off valves must be installed to stop fuel
flow. Starboard side fuel shut off valve does not close
all the way.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2020
Resolved 20 August 2020
Resolution: Witnessed satisfactory test of the fuel shut off valve. Valve completely closed when operated by fuel shutoff system.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 7 October 2017
Resolved
Prove proper operation of aft bilge pump
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 10 October 2017
Resolution: Aft bilge pump demonstrated satisfactory operation.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 19 June 2017
Resolved
Secure overboard discharge of sewage with padlock, or some acceptable means per 33CFR159.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 19 June 2017
Resolution: the vessel rep installed a padlock on the spot.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 June 2017
Resolved
provide log of monthly drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 19 June 2017
Resolution: conducted credit drills while underway.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 April 2016
Resolved
Vessel must undergo a "New to Zone" Inspection by the cognizant OCMI (Puerto Rico) prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2016
Resolution: Sector San Juan completed New to Zone