MAURY USCG vessel records
← All vessels

SUN GAS

SUN GAS is a 1998 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in June 2026, along with 6 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 9 June 2026.

Built
1998
Last inspected
9 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9186948
1380899
Flag
BELIZE
Maury page id
psix-1380899

Documentation record

Tonnage as PSIX records it3392 - Convention (Subpart B), Gross Ton
3318 - Dead Weight, Metric Ton
5546 - Displacement, Metric Ton
1018 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

9 June 2026 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8395534
18 February 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8311977
27 January 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8302257
5 January 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8290054
12 December 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8282747
25 November 2025 Deficiency Check · COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8272829
20 May 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8139741
13 March 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8092991
22 December 2024 Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8050222
13 November 2024 COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8034518
20 November 2023 PSC B · COC-GAS Annual · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7827446
29 August 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7780233
8 November 2022 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7591898
1 November 2022 COC-GAS Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7587340
14 October 2021 COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7330549
28 October 2020 PSC B · Administrative Inspection · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7083742
10 November 2019 ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6851328
14 October 2018 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6560313
15 March 2016 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5833548

Deficiency record · 6

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 November 2025 Resolved
ON SHIPS CARRYING FLAMMABLE OR TOXIC PRODUCTS OR BOTH, A WATER SPRAY SYSTEM FOR COOLING, FIRE PREVENTION AND CREW PROTECTION SHOULD BE INSTALLED TO COVER EXPOSED CARGO TANK DOMES AND ANY EXPOSED PARTS OF CARGO TANKS. PSCO OBSERVED INSUFFICIENT PRESSURE TO COVER TANK DOMES 1 AND 2. 74SOLAS(20) VII/13.1 IGC (93) 11.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2025
Resolution: Vessel sent in class report rectifying the deficiency
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 November 2025 Resolved
THE CONTROL SYSTEM FOR ALL REQUIRED EMERGENCY SHUTDOWN VALUES SHOULD BE SO ARRANGED THAT ALL SUCH VALUES MAY BE OPERATED BY SINGLE CONTROLS SITUATED IN AT LEAST TWO REMOTE LOCATIONS ON THE SHIP. ONE OF THESE LOCATIONS SHOULD BE THE CONTROL POSITION REQUIRED BY 13.1.3 OR CARGO CONTROL ROOM. THE CONTROL SYSTEM SHOULD ALSO BE PROVIDED WITH FUSIBLE ELEMENTS DESIGNED TO MELT AT TEMPERATURES BETWEEN 98°C AND 104°C WHICH WILL CAUSE THE EMERGENCY SHUTDOWN VALVES TO CLOSE IN THE EVENT OF FIRE. PSCO OBSERVED THE FUSIBLE ELEMENTS PAINTED ON THE #1 AND #2 CARGO TANK LIQUID CARGO FILL LINES AND ON THE PORT SIDE MANIFOLD. 74 SOLAS (20) VII/13.1 IGC (93) 5.6.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2025
Resolution: Vessel sent in class report rectifying the deficiency
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 November 2025 Resolved
THE VAPOR SPACE OF EACH CARGO TANK SHOULD BE PROVIDED WITH A PRESSURE GAUGE WHICH SHOULD INCORPORATE AN INDICATOR IN THE CONTROL POSITION REQUIRED BY 13.1.3. THE ALARMS SHOULD BE ACTIVATED BEFORE THE SET PRESSURES ARE REACHED. PSCO OBSERVED THE PRESSURE INPUT TO THE SENSOR ON THE #2 CARGO TANK DISCONNECTED. SHIP’S CREW PERFORMED MAINTENANCE AND RECTIFIED. 74SOLAS(20) VII/13.1 IGC (93) 13.4.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2025
Resolution: CREW RECTIFIED ON THE SPOT.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 25 November 2025 Resolved
Each Flammable gas detection system must have an audible and visual alarm for power failure and loss of gas sampling flow. PSCO observed the fixed gas detection power failure alarm inoperable. 46 CFR 154.1350(f)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 November 2025
Resolution: Vessel sent in class report rectifying the deficiency
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 21 March 2016 Resolved
0999-Other (safety in general)Gas detection equipment should be so designed that it may readily be tested. Testing & calibration should be carried out at regular intervals. PSCO note, during calibration of gas detection equipment, that the system was out of calibration.-IGC 13.6.6. a-prior to cargo
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2016
Resolved 22 March 2016
Resolution: Accepted Lloyd's Register class report with technician report noting proper calibration and testing of the gas detection system.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 21 March 2016 Resolved
1099(Other alarm signals) Each cargo tank should be fitted with a high level alarm operating independently of other liquid level indicators and giving an audible and visual warning when activated. Crew was unable to demonstrate operation of the sensor and vsl was unable to provide testing procedures for the high level alarm. IGC 13.3.1 - 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 22 March 2016
Resolution: Accepted Lloyd's Register class report noting implemenation of testing procedures.