Records from 2016 to 2026. Most recent: inspection, 22 April 2026.
Inspection history · 18
22 April 2026
COI Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8353137
19 March 2026
Drydock Exam · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8328412
14 April 2025
Annual Inspection · Hull Examination
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8111867
14 March 2024
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7879210
11 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7666755
16 September 2022
Type not recorded
No type recorded · Station Kauai · USCG Oceania District (CGD-O) · Activity 7560690
23 March 2022
Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7409871
2 February 2022
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7389351
18 December 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7374006
23 April 2021
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7182075
4 December 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7106567
30 July 2020
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7012377
27 May 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6962139
13 June 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6714229
30 March 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6665485
24 April 2018
Administrative Inspection · Internal Structural Exam · DAPI Audit · Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6398780
30 May 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6168020
26 April 2016
COI Inspection · Initial Certification · Hull Examination · Internal Structural Exam · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5863281
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 April 2026
Resolved
The fuel tank space can only contain the tank and associated piping. It shall be free from any ignition sources. Gasoline fuel tank space was not segregated from ignition sources. Provide segregated space or provide a pre-engineered fixed fire fighting system.
Sector Honolulu Work Instruction 07(03)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2026
Resolution: Fuel tank space segregated from ignition source.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2026
Resolved
Battery installations must be mounted to protect against shifting of the vessel. Battery boxes not secured. Provide secure battery boxes.
46 CFR 183.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2026
Resolved 25 June 2026
Resolution: Battery box secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2026
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Power conductor in bilge. Provide support for conductor so it is not in the bilge.
46 CFR 183.340 (b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2026
Resolved 25 June 2026
Resolution: Wire removed from bilge.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2026
Resolved
Portable extinguisher must be located so that they are clearly visible. Extinguisher stowed in cabinet and no marking provided. Provide marking on exterior of storage area to show that extinguisher is inside.
46 CFR 181.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2026
Resolved 25 June 2026
Resolution: Fire extinguisher marking provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2026
Resolved
The owner shall, prior to receiving a Certificate of Inspection, submit for approval to the cognizant OCMI, the following plans, manuals, analyses, and calculations that are applicable to the vessel as determined by the OCMI: Fuel tank plans. Plans not provided. Provide fuel tank plans.
46 CFR 177.202
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2026
Resolved 15 April 2026
Resolution: Fuel tank plan submitted and approved.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 April 2023
Resolved
Vessel Captain does not hold a FCC Marine Operator Permit. Master must uphold this certification. Prove the Captain has satisfactory completed the training and provide the certificate to the MI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2023
Resolved 2 May 2023
Resolution: Master provided FCC operator permit.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 April 2023
Resolved
Vessel does not have a sound signal onboard. Provide a serviceable sound producing device and prove its readily available.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 18 April 2023
Resolution: Vessel provided serviceable sound signal device.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2023
Resolved
Vessel's life ring does not have reflective material. Provide approved reflective tape and prove life ring is serviceable to the MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 19 April 2023
Resolution: Vessel provided serviceable life ring.
Lifesaving › Lifebuoys › Size
Issued 30 May 2017
Resolved
Ring buoy on board was not adequate size.
Condition: Placed in Improper Service
Due 9 June 2017
Resolved 1 June 2017
Resolution: Replaced ring buoy with prescribed size and stenciled correctly.
Documentation › Logs/Records › Logbook (official)
Issued 30 May 2017
Resolved
Logbook did not contain required drills and training.
Condition: Improper/Lack of Maintenance
Due 9 June 2017
Resolved 1 June 2017
Resolution: Corrected all logbooks to contain required drills and training.
Documentation › Markings/Placards › Certificate of Number (state)
Issued 30 May 2017
Resolved
State numbers were found rubbed off hull.
Condition: Improper/Lack of Maintenance
Due 9 June 2017
Resolved 1 June 2017
Resolution: Replaced state numbers on hull in kind.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 30 May 2017
Resolved
Oil discharge placard was not posted properly.
Condition: Improper/Lack of Maintenance
Due 9 June 2017
Resolved 1 June 2017
Resolution: Posted proper oil discharge placard.
Documentation › Markings/Placards › Lifejacket Placard
Issued 30 May 2017
Resolved
Life jacket donning placard not posted.
Condition: Improper/Lack of Maintenance
Due 9 June 2017
Resolved 1 June 2017
Resolution: Posted proper life jacket donning procedure placard.