MAURY USCG vessel records
← All vessels

OCEAN I

OCEAN I is a 1993 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in April 2026, along with 13 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 22 April 2026.

Built
1993
Last inspected
22 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 April 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI7165
1381177
Flag
UNITED STATES
Maury page id
psix-1381177

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
3 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

22 April 2026 COI Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8353137
19 March 2026 Drydock Exam · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8328412
14 April 2025 Annual Inspection · Hull Examination
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8111867
14 March 2024 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7879210
11 April 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7666755
16 September 2022 Type not recorded
No type recorded · Station Kauai · USCG Oceania District (CGD-O) · Activity 7560690
23 March 2022 Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7409871
2 February 2022 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7389351
18 December 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7374006
23 April 2021 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7182075
4 December 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7106567
30 July 2020 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7012377
27 May 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6962139
13 June 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6714229
30 March 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6665485
24 April 2018 Administrative Inspection · Internal Structural Exam · DAPI Audit · Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6398780
30 May 2017 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6168020
26 April 2016 COI Inspection · Initial Certification · Hull Examination · Internal Structural Exam · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5863281

Deficiency record · 13

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 April 2026 Resolved
The fuel tank space can only contain the tank and associated piping. It shall be free from any ignition sources. Gasoline fuel tank space was not segregated from ignition sources. Provide segregated space or provide a pre-engineered fixed fire fighting system. Sector Honolulu Work Instruction 07(03)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2026
Resolution: Fuel tank space segregated from ignition source.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2026 Resolved
Battery installations must be mounted to protect against shifting of the vessel. Battery boxes not secured. Provide secure battery boxes. 46 CFR 183.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2026
Resolved 25 June 2026
Resolution: Battery box secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2026 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Power conductor in bilge. Provide support for conductor so it is not in the bilge. 46 CFR 183.340 (b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2026
Resolved 25 June 2026
Resolution: Wire removed from bilge.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2026 Resolved
Portable extinguisher must be located so that they are clearly visible. Extinguisher stowed in cabinet and no marking provided. Provide marking on exterior of storage area to show that extinguisher is inside. 46 CFR 181.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2026
Resolved 25 June 2026
Resolution: Fire extinguisher marking provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2026 Resolved
The owner shall, prior to receiving a Certificate of Inspection, submit for approval to the cognizant OCMI, the following plans, manuals, analyses, and calculations that are applicable to the vessel as determined by the OCMI: Fuel tank plans. Plans not provided. Provide fuel tank plans. 46 CFR 177.202
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2026
Resolved 15 April 2026
Resolution: Fuel tank plan submitted and approved.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 April 2023 Resolved
Vessel Captain does not hold a FCC Marine Operator Permit. Master must uphold this certification. Prove the Captain has satisfactory completed the training and provide the certificate to the MI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2023
Resolved 2 May 2023
Resolution: Master provided FCC operator permit.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 April 2023 Resolved
Vessel does not have a sound signal onboard. Provide a serviceable sound producing device and prove its readily available.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 18 April 2023
Resolution: Vessel provided serviceable sound signal device.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2023 Resolved
Vessel's life ring does not have reflective material. Provide approved reflective tape and prove life ring is serviceable to the MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 19 April 2023
Resolution: Vessel provided serviceable life ring.
Lifesaving › Lifebuoys › Size
Issued 30 May 2017 Resolved
Ring buoy on board was not adequate size.
Condition: Placed in Improper Service
Due 9 June 2017
Resolved 1 June 2017
Resolution: Replaced ring buoy with prescribed size and stenciled correctly.
Documentation › Logs/Records › Logbook (official)
Issued 30 May 2017 Resolved
Logbook did not contain required drills and training.
Condition: Improper/Lack of Maintenance
Due 9 June 2017
Resolved 1 June 2017
Resolution: Corrected all logbooks to contain required drills and training.
Documentation › Markings/Placards › Certificate of Number (state)
Issued 30 May 2017 Resolved
State numbers were found rubbed off hull.
Condition: Improper/Lack of Maintenance
Due 9 June 2017
Resolved 1 June 2017
Resolution: Replaced state numbers on hull in kind.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 30 May 2017 Resolved
Oil discharge placard was not posted properly.
Condition: Improper/Lack of Maintenance
Due 9 June 2017
Resolved 1 June 2017
Resolution: Posted proper oil discharge placard.
Documentation › Markings/Placards › Lifejacket Placard
Issued 30 May 2017 Resolved
Life jacket donning placard not posted.
Condition: Improper/Lack of Maintenance
Due 9 June 2017
Resolved 1 June 2017
Resolution: Posted proper life jacket donning procedure placard.

Ownership record